EL1262 Beckhoff EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs, oversampling
KKM Solutions is an independent parts distributor, not an authorized Beckhoff dealer — how we source.
Beckhoff EL1262 - EtherCAT Terminals - Weight: approx. 55 g; Operating Temperature: 0…55°C; Storage Temperature: -25…+85°C.
Overview
Part number EL1262 from Beckhoff, listed in Fieldbus Modules & Gateways. Specifications on file: Approvals/markings CE, CCC, UL, ATEX, IECEx, cFMus; Bit width in the process image n x 2 inputs + 64 bit CycleCounter/latch; Connection technology 4-wire; Current consumption E-bus typ. 70 mA. KKM Solutions quotes this part with pricing and availability confirmed per order.
Beckhoff EL1262 is an EtherCAT Terminals catalog item from Beckhoff. The manufacturer's published data for this part number specifies Weight: approx. 55 g and Operating Temperature: 0…55°C.
ATEX:
II 3 G Ex ec IIC T4 Gc
IECEx:
Ex ec IIC T4 Gc
cFMus:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx ec IIC T4 Gc
Published specifications for this part include Storage Temperature: -25…+85°C; Relative Humidity: 95%, no condensation; Special Features: oversampling; Nominal Voltage: 24 V DC (-15%/+20%); Approvals/markings: CE, CCC, UL, ATEX, IECEx, cFMus; Vibration/shock resistance: conforms to EN 60068-2-6/EN 60068-2-27; EMC immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4; Electrical isolation: 500 V (E-bus/field potential); Protect. rating/installation pos.: IP20/variable; Current consumption E-bus: typ. 70 mA; Number of inputs: 2; Signal voltage “0”: -3…+5 V (EN 61131-2, type 3). The complete technical table is shown in the Specifications tab on this page.
Specifications
| Approvals/markings | CE, CCC, UL, ATEX, IECEx, cFMus |
|---|---|
| Bit width in the process image | n x 2 inputs + 64 bit CycleCounter/latch |
| Connection technology | 4-wire |
| Current consumption E-bus | typ. 70 mA |
| Current consumption power contacts | typ. 20 mA + load |
| Distributed clocks | yes |
| Electrical isolation | 500 V (E-bus/field potential) |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Ex marking | ATEX: II 3 G Ex ec IIC T4 Gc IECEx: Ex ec IIC T4 Gc cFMus: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx ec IIC T4 Gc |
| Input current | typ. 3 mA |
| Nominal Voltage | 24 V DC (-15%/+20%) |
| Number of inputs | 2 |
| Operating Temperature | 0…55°C |
| Oversampling/multi-timestamp factor | n = integer multiple of the cycle time, 1…1000, see documentation |
| Pluggable wiring level | for all ESxxxx terminals |
| Protect. rating/installation pos. | IP20/variable |
| Relative Humidity | 95%, no condensation |
| Sampling rate | max. 1 Msample/s |
| Signal voltage “0” | -3…+5 V (EN 61131-2, type 3) |
| Signal voltage “1” | 11…30 V (EN 61131-2, type 3) |
| Special Features | oversampling |
| Specification | similar to EN 61131-2, type 3, “0”: -3…5 V DC, “1”: 11…30 V DC, typ. 3 mA input current |
| Storage Temperature | -25…+85°C |
| Timestamp accuracy in the terminal | 10 ns (+ input delay) |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| Weight | approx. 55 g |
Product details
| Manufacturer | Beckhoff |
|---|---|
| Manufacturer part number | EL1262 |
| Product category | Fieldbus Modules & Gateways |
| Published specifications | 26 attributes listed |
| Related part numbers | 7 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for EL1262?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the EL1262?
EL1262 is made by Beckhoff and is listed in our Fieldbus Modules & Gateways category. KKM Solutions is an independent distributor, not an authorized Beckhoff dealer: we source the exact Beckhoff part number EL1262, and the quote confirms condition and lead time before you order.
Is the EL1262 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the EL1262, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of EL1262?
No published lifecycle status is on file for EL1262. Beckhoff lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of EL1262?
Key specifications include Approvals/markings: CE, CCC, UL, ATEX, IECEx, cFMus; Bit width in the process image: n x 2 inputs + 64 bit CycleCounter/latch; Connection technology: 4-wire; Current consumption E-bus: typ. 70 mA. The full specification table on this page lists every published attribute for this part.
What voltage does EL1262 use?
Per the published specification for EL1262: Nominal Voltage: 24 V DC (-15%/+20%); Signal voltage “0”: -3…+5 V (EN 61131-2, type 3). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What operating temperature is EL1262 rated for?
Per the published specification for EL1262: Operating Temperature: 0…55°C. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How much does EL1262 weigh?
Per the published specification for EL1262: Weight: approx. 55 g. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can EL1262 ship?
Lead time for EL1262 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other Beckhoff part numbers in this family:
Frequently Searched Beckhoff Part Numbers
Related Products
Beckhoff Beckhoff EtherCAT Terminal, 2-channel digital input, 24 V DC,…
Beckhoff Beckhoff EtherCAT Terminal, 8-channel digital input, 24 V DC,…
Beckhoff Beckhoff EtherCAT Terminal, 2-channel digital input, 24 V DC,…
Beckhoff Beckhoff EtherCAT Terminal, 16-channel digital input, 24 V DC,…
Beckhoff Beckhoff EtherCAT Terminal, 4-channel digital input, 48 V DC,…
Beckhoff Beckhoff EtherCAT Terminal, 16-channel digital input, 24 V DC,…
More Fieldbus Modules & Gateways parts
Technical Guides
Browse more Beckhoff Industrial Networking, or see everything from Beckhoff.
Industrial Automation & MRO Parts