Beckhoff EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs, timestamp EL1252

EL1252 Beckhoff EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs, timestamp

Brand: Beckhoff SKU: EL1252 Mfr Part #: EL1252

KKM Solutions is an independent parts distributor, not an authorized Beckhoff dealer — how we source.

Ships worldwide — lead time quoted per part

Beckhoff EL1252 - EtherCAT Terminals - Weight: approx. 55 g; Operating Temperature: -25…+60°C; Storage Temperature: -40…+85°C.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number EL1252 from Beckhoff, listed in Fieldbus Modules & Gateways. Specifications on file: Approvals/markings CE, CCC, UL, ATEX, IECEx; Bit width in the process image 2 x input + 2 x 16 byte timestamp; Configuration no address or configuration setting; Connection technology 4-wire. KKM Solutions quotes this part with pricing and availability confirmed per order.

This listing covers the Beckhoff EL1252, a part number in the EtherCAT Terminals category. The manufacturer's published data for this part number specifies Weight: approx. 55 g and Operating Temperature: -25…+60°C.

similar to EN 61131-2, type 3, “0”: -3…5 V DC, “1”: 11…30 V DC, typ. 3 mA input current

Published specifications for this part include Storage Temperature: -40…+85°C; Relative Humidity: 95%, no condensation; Special Features: timestamping, latch last edge; Nominal Voltage: 24 V DC (-15%/+20%); Approvals/markings: CE, CCC, UL, ATEX, IECEx; Vibration/shock resistance: conforms to EN 60068-2-6/EN 60068-2-27; EMC immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4; Ex marking: ATEX:
II 3 G Ex ec IIC T4 Gc
IECEx:
Ex ec IIC T4 Gc; Electrical isolation: 500 V (E-bus/field potential); Protect. rating/installation pos.: IP20/variable; Configuration: no address or configuration setting; Current consumption E-bus: typ. 110 mA. See the Specifications tab on this page for the full technical table.

Specifications

Approvals/markings CE, CCC, UL, ATEX, IECEx
Bit width in the process image 2 x input + 2 x 16 byte timestamp
Configuration no address or configuration setting
Connection technology 4-wire
Current consumption E-bus typ. 110 mA
Current consumption power contacts –
Distributed clocks yes
Electrical isolation 500 V (E-bus/field potential)
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Ex marking ATEX: II 3 G Ex ec IIC T4 Gc IECEx: Ex ec IIC T4 Gc
Input current typ. 3 mA (similar to EN 61131-2, type 3)
Nominal Voltage 24 V DC (-15%/+20%)
Number of inputs 2
Operating Temperature -25…+60°C
Pluggable wiring level for all ESxxxx terminals
Protect. rating/installation pos. IP20/variable
Relative Humidity 95%, no condensation
Signal voltage “0” -3…+5 V (similar to EN 61131-2, type 3)
Signal voltage “1” 11…30 V (similar to EN 61131-2, type 3)
Special Features timestamping, latch last edge
Specification similar to EN 61131-2, type 3, “0”: -3…5 V DC, “1”: 11…30 V DC, typ. 3 mA input current
Storage Temperature -40…+85°C
Time resolution signal 1 ns
Timestamp accuracy in the terminal 10 ns (+ input delay)
Timestamp resolution 1 ns
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
Weight approx. 55 g

Product details

Manufacturer Beckhoff
Manufacturer part number EL1252
Product category Fieldbus Modules & Gateways
Published specifications 27 attributes listed
Related part numbers 7 other part numbers in this family

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How much does EL1252 cost?

EL1252 is available for direct purchase at CA$459.67 (CAD), shown on this page with an Add to Cart button. Larger quantities or custom terms — email orderdesk@kkmsolutions.com for a volume quote.

Who manufactures the EL1252?

EL1252 is made by Beckhoff and is listed in our Fieldbus Modules & Gateways category. KKM Solutions is an independent distributor, not an authorized Beckhoff dealer: we source the exact Beckhoff part number EL1252, and the quote confirms condition and lead time before you order.

Is the EL1252 new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the EL1252, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of EL1252?

No published lifecycle status is on file for EL1252. Beckhoff lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of EL1252?

Key specifications include Approvals/markings: CE, CCC, UL, ATEX, IECEx; Bit width in the process image: 2 x input + 2 x 16 byte timestamp; Configuration: no address or configuration setting; Connection technology: 4-wire. The full specification table on this page lists every published attribute for this part.

What voltage does EL1252 use?

Per the published specification for EL1252: Nominal Voltage: 24 V DC (-15%/+20%); Signal voltage “0”: -3…+5 V (similar to EN 61131-2, type 3). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

What operating temperature is EL1252 rated for?

Per the published specification for EL1252: Operating Temperature: -25…+60°C. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How much does EL1252 weigh?

Per the published specification for EL1252: Weight: approx. 55 g. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How quickly can EL1252 ship?

Lead time for EL1252 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Variants & Related Part Numbers

Other Beckhoff part numbers in this family:

Frequently Searched Beckhoff Part Numbers

Related Products

More Fieldbus Modules & Gateways parts

Browse Beckhoff part numbers starting with EL1 ›

Technical Guides

All PLC, HMI & Industrial Networking articles ›

Browse more Beckhoff Industrial Networking, or see everything from Beckhoff.