SD8501 IFM Compressed air meter
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM SD8501 - Compressed air meter - Storage Temperature: -4...185; Display range: -15...290.
Overview
Part number SD8501 from IFM, listed in Pneumatics. Specifications on file: Ambient temperature 32...140; Analog current output 4...20; (scalable); Analog end point 32...232; Analog start point -15...186. KKM Solutions quotes this part with pricing and availability confirmed per order.
IFM SD8501 is a Compressed air meter catalog item from IFM. The manufacturer's published data for this part number specifies Weight: 1581 and Storage Temperature: -4...185.
PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM
The specification set recorded for this part number covers Display range: -15...290; Ambient temperature: 32...140; Connector: 1 x M12; coding: A; Contacts: 4; Protection class: III; Dimensions: 475 x 45.4 x 83.1; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: Compressed air meter; Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Response time: < 0.1; (dAP = 0, T09); Communication interface: IO-Link. See the Specifications tab on this page for the full technical table.
Specifications
| Accuracy | ± 0,5; (medium flow in the limit area of the flow measurement range) |
|---|---|
| Accuracy (in the measuring range) | class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 73 °F |
| Ambient temperature | 32...140 |
| Analog current output | 4...20; (scalable) |
| Analog end point | 32...232 |
| Analog start point | -15...186 |
| Application | for industrial applications |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4 |
| Damping process value dAP | 0...5 |
| Dimensions | 475 x 45.4 x 83.1 |
| Display range | -15...290 |
| Dynamic response T05 / T09 | T09 = 0,5 |
| Electrical design | PNP/NPN |
| Greatest TEMPCO of the span | ± 0,3 |
| Greatest TEMPCO of the zero point | ± 0,1 |
| Housing | rectangular |
| In steps of | 1 |
| Inputs | counter reset |
| IO-Link revision | 1.1 |
| Key Features | Precise measurement of flow, consumption, pressure and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting compressed air in industrial use; Red/green display for clear identification of the acceptable range; Display can be rotated for optimum alignment |
| Material | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM |
| Materials (wetted parts) | stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
| MAWP (for applications according to CRN) | 10.5 |
| Max. load | 500 |
| Max. relative air humidity | 90 |
| Max. voltage drop switching output DC | 2.5 |
| Measuring range | -15...232 |
| Media | compressed air |
| Medium temperature | -10...60 |
| Min. burst pressure | 928 |
| Min. process cycle time | 7.2 |
| MTTF | 183 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 18...30 DC; (to SELV/PELV) |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer |
| Permanent current rating of switching output DC | 150; (per output) |
| Power-on delay time | 1 |
| Pressure equipment directive | sound engineering practice; can be used for stable gases fluid group 2 |
| Pressure Rating | 232 |
| Process Connection | threaded connection 1" NPT external thread DN25 |
| Process data analog | 8 |
| Process data binary | 2 |
| Product type | Compressed air meter |
| Protection | IP 65; IP 67 |
| Protection class | III |
| Pulse length | 0.007...2 |
| Pulse output | consumed quantity meter |
| Repeatability | ± (0,4 % MW + 0,1 % MEW) |
| Required master port class | A |
| Reset point rP | -15...231 |
| Resolution | 1 |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 CDV |
| Set point SP | -13...232 |
| Short circuit protection | yes |
| SIO mode | yes |
| Specification Summary | Compressed air meter; PNP/NPN; switching signal; analog signal; pulse signal; IO-Link; Medium temperature -10...60 °C; 1" NPT external thread DN25; Connector |
| Storage Temperature | -4...185 |
| Temperature coefficient | ± 0,07 % MW |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | yes (non-latching) |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | SD8501 |
| Product category | Pneumatics |
| Published specifications | 68 attributes listed |
| Related part numbers | 1 other part number in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for SD8501?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SD8501?
SD8501 is made by IFM and is listed in our Pneumatics category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SD8501, and the quote confirms condition and lead time before you order.
Is the SD8501 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the SD8501, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of SD8501?
No published lifecycle status is on file for SD8501. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of SD8501?
Key specifications include Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 73 °F; Ambient temperature: 32...140; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
What voltage does SD8501 use?
Per the published specification for SD8501: Max. voltage drop switching output DC: 2.5; Operating voltage: 18...30 DC; (to SELV/PELV). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of SD8501?
Per the published specification for SD8501: Permanent current rating of switching output DC: 150; (per output). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is SD8501 made of?
Per the published specification for SD8501: Material: PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can SD8501 ship?
Lead time for SD8501 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other IFM part numbers in this family:
Frequently Searched IFM Part Numbers
Related Products
IFM Compressed air meter - SD8500
IFM Compressed air meter - SD8001
IFM Compressed air meter - SD9000
IFM Compressed air meter - SD8000
IFM Compressed air meter - SD9500
IFM Compressed air meter - SDG070
Technical Guides
Browse more IFM Pneumatics, or see everything from IFM.
Industrial Automation & MRO Parts