Compressed air meter - SD8001
IFM SD8001 - Compressed air meter - Weight: 1979.5; Storage Temperature: -4...185; Display range: 32...140.
IFM SD8001 is a Compressed air meter catalog item from IFM. The manufacturer's published data for this part number specifies Weight: 1979.5 and Storage Temperature: -4...185.
PBT-GF20; NBR; PC; stainless steel (1.4306 / 304L); PTFE; brass coated; aluminum powder-coated
Key manufacturer data on file for this item includes Display range: 32...140; Ambient temperature: 32...140; Connector: 1 x M12; coding: A; Contacts: 4; Protection class: III; Dimensions: 475 x 45 x 88.5; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; (configurable); Product type: Compressed air meter; Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Response time: 0.1; (dAP = 0); Measuring range: 32...140. See the Specifications tab on this page for the full technical table.
| Accuracy | ± 2; (medium flow in the limit area of the flow measurement range) |
|---|---|
| Accuracy (in the measuring range) | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN25) |
| Ambient temperature | 32...140 |
| Analog current output | 4...20; (scalable) |
| Application | for industrial applications |
| Connector | 1 x M12; coding: A; Contacts: 4 |
| Current consumption | < 100 |
| Damping process value dAP in steps | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
| Dimensions | 475 x 45 x 88.5 |
| Display range | 32...140 |
| Electrical design | PNP |
| Housing | rectangular |
| In steps of | 0.020...1000 scf |
| Key Features | Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting compressed air in industrial use; With switching output, analog output and pulse output; Clearly visible numerical display |
| Material | PBT-GF20; NBR; PC; stainless steel (1.4306 / 304L); PTFE; brass coated; aluminum powder-coated |
| Materials (wetted parts) | stainless steel (1.4306 / 304L); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminum |
| MAWP (for applications according to CRN) | 16 |
| Max. load | 500 |
| Max. relative air humidity | 90 |
| Max. voltage drop switching output DC | 2 |
| Measuring range | 32...140 |
| Media | compressed air |
| Medium temperature | 32...140 |
| MTTF | 227 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 19...30 DC; (to SELV/PELV) |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit |
| Permanent current rating of switching output DC | 250; (per output) |
| Power-on delay time | 0.5 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Process Connection | threaded connection 1" NPT external thread DN25 |
| Product type | Compressed air meter |
| Protection | IP 65 |
| Protection class | III |
| Pulse length | 0,045...2 |
| Pulse output | consumed quantity meter |
| Pulse value | 0.120...4 000 000 scf |
| Repeatability | ± 1,5 |
| Response time | 0.1; (dAP = 0) |
| Reverse polarity protection | yes |
| Short circuit protection | yes |
| Specification Summary | Compressed air meter; PNP; switching signal; analog signal; pulse signal; Pressure rating 16 bar; 1" NPT external thread DN25; Connector |
| Storage Temperature | -4...185 |
| Total number of outputs | 2 |
| Type of short-circuit protection | yes (non-latching) |
| Weight | 1979.5 |
Frequently Asked Questions
How do I get pricing for SD8001?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SD8001?
SD8001 is a IFM part. KKM Solutions sources IFM components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of SD8001?
Key specifications include Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN25); Ambient temperature: 32...140; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
How quickly can SD8001 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
IFM Compressed air meter - SD8000
IFM Compressed air meter - SD8500
IFM Compressed air meter - SD8501
IFM Compressed air meter - SD6501
IFM Compressed air meter - SD9000
IFM
Industrial & MRO Parts