SD9000 IFM Compressed air meter
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM SD9000 - Compressed air meter - Storage Temperature: -20...85; Display range: -12...72.
Overview
Part number SD9000 from IFM, listed in Pneumatics. Specifications on file: Ambient temperature 0...60; Analog current output 4...20; (scalable); Application for industrial applications; Communication interface IO-Link. KKM Solutions quotes this part with pricing and availability confirmed per order.
In our catalog, the SD9000 from IFM is listed under the Compressed air meter category. The manufacturer's published data for this part number specifies Weight: 4004 and Storage Temperature: -20...85.
PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; aluminum powder-coated
Key manufacturer data on file for this item includes Display range: -12...72; Ambient temperature: 0...60; Connector: 1 x M12; coding: A; Contacts: 4; Protection class: III; Dimensions: 475 x 90 x 120; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: Compressed air meter; Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Response time: 0.1; (dAP = 0); Communication interface: IO-Link. See the Specifications tab on this page for the full technical table.
Specifications
| Accuracy | ± 2; (medium flow in the limit area of the flow measurement range) |
|---|---|
| Accuracy (in the measuring range) | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN40) |
| Ambient temperature | 0...60 |
| Analog current output | 4...20; (scalable) |
| Application | for industrial applications |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4 |
| Damping process value dAP in steps | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
| Dimensions | 475 x 90 x 120 |
| Display range | -12...72 |
| Electrical design | PNP |
| Housing | rectangular |
| In steps of | 0.001 m³ |
| IO-Link revision | 1.1 |
| Key Features | Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting compressed air in industrial use; With switching output, analog output and pulse output; Clearly visible numerical display |
| Material | PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; aluminum powder-coated |
| Materials (wetted parts) | stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminum |
| Max. load | 500 |
| Max. relative air humidity | 90 |
| Max. voltage drop switching output DC | 2 |
| Measuring range | 0...60 |
| Media | compressed air |
| Medium temperature | 0...60 |
| Min. process cycle time | 4.1 |
| MTTF | 227 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 18...30 DC; (to SELV/PELV) |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer |
| Permanent current rating of switching output DC | 250; (per output) |
| Power-on delay time | 1 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Process Connection | threaded connection R 1 1/2 external thread DN40 |
| Process data analog | 3 |
| Process data binary | 2 |
| Product type | Compressed air meter |
| Protection | IP 65 |
| Protection class | III |
| Pulse length | 0,018...2 |
| Pulse output | consumed quantity meter |
| Pulse value | 0.005...4 000 000 m³ |
| Repeatability | ± 1,5 |
| Required master port class | A |
| Response time | 0.1; (dAP = 0) |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 CDV |
| Short circuit protection | yes |
| SIO mode | yes |
| Specification Summary | Compressed air meter; PNP; switching signal; analog signal; pulse signal; IO-Link; Measuring range 1.5...410 m³/h; Measuring range 20...6835 l/min; Medium temperature 0...60 °C; Pressure rating 16 bar; R 1 1/2 external thread DN40; Connector |
| Storage Temperature | -20...85 |
| Total number of outputs | 2 |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | yes (non-latching) |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | SD9000 |
| Product category | Pneumatics |
| Published specifications | 58 attributes listed |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for SD9000?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SD9000?
SD9000 is made by IFM and is listed in our Pneumatics category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SD9000, and the quote confirms condition and lead time before you order.
Is the SD9000 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the SD9000, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of SD9000?
No published lifecycle status is on file for SD9000. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of SD9000?
Key specifications include Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN40); Ambient temperature: 0...60; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
What voltage does SD9000 use?
Per the published specification for SD9000: Max. voltage drop switching output DC: 2; Operating voltage: 18...30 DC; (to SELV/PELV). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of SD9000?
Per the published specification for SD9000: Permanent current rating of switching output DC: 250; (per output). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is SD9000 made of?
Per the published specification for SD9000: Material: PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; aluminum powder-coated. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can SD9000 ship?
Lead time for SD9000 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Frequently Searched IFM Part Numbers
Related Products
IFM Compressed air meter - SD9500
IFM Compressed air meter - SDG070
IFM Compressed air meter - SD8501
IFM Compressed air meter - SDG080
IFM Compressed air meter - SD8500
IFM Compressed air meter - SDG350
Technical Guides
Browse more IFM Pneumatics, or see everything from IFM.
Industrial Automation & MRO Parts