Skip to content
Stock is confirmed when you order, and we will advise you as soon as your order is confirmed. Need help with a part? Email orderdesk@kkmsolutions.com.
Ships worldwide — lead time quoted per part (825) 454-5367 Order desk 24/7 orderdesk@kkmsolutions.com
KKM Industrial and Automation Solutions Industrial Automation & MRO Parts Line down? Call the order desk (825) 454-536724/7
Call the order desk Get a quote
IFM Evaluation unit for monitoring analog standard signals - DL3003

DL3003 IFM Evaluation unit for monitoring analog standard signals

Brand: IFM SKU: DL3003 Mfr Part #: DL3003

KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.

Ships worldwide — lead time quoted per part

IFM DL3003 - Evaluation unit for monitoring analog standard signals - Material: housing: plastics; Storage Temperature: -40...85.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number DL3003 from IFM, listed in Monitoring & Measuring Relays. Specifications on file: Ambient temperature -40...60; Analog current output 4...20; (max.. 20,5 mA); Analog input (current) 0...20; Analog input (voltage) 0...10. KKM Solutions quotes this part with pricing and availability confirmed per order.

In our catalog, the DL3003 from IFM is listed under the Evaluation unit for monitoring analog standard signals category. The manufacturer's published data for this part number specifies Material: housing: plastics.

16.5...27.7; (Short-circuit proof; DC operation: ≤ 200 mA; AC operation: ≤ 150 mA)

Published specifications for this part include Storage Temperature: -40...85; Type of mounting: Mounting on DIN rail; (TH35 (EN 60715)); Ambient temperature: -40...60; Dimensions: 126 x 50 x 112.4; Number of digital outputs: 2; Application: 2-channel analog threshold relay for analog standard signals; Contact rating: 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating; B300: 6000 cycles); Pollution degree: 2; Product type: Evaluation unit for monitoring analog standard signals; Accuracy: ± 0.25; (% of the final value 45 °C 0.25 % + Temperature coefficient); Short-circuit-proof: yes; Overvoltage category: II. See the Specifications tab on this page for the full technical table.

Specifications

Ambient temperature -40...60
Analog current output 4...20; (max.. 20,5 mA)
Analog input (current) 0...20
Analog input (voltage) 0...10
Application 2-channel analog threshold relay for analog standard signals
Auxiliary energy for sensors DC 16.5...27.7; (Short-circuit proof; DC operation: ≤ 200 mA; AC operation: ≤ 150 mA)
cage clamps ...2.5 mm²
Circuit PNP
Communication interface IO-Link
Contact rating 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating; B300: 6000 cycles)
Current consumption AC operation: max. 8 A (including maximum AC supply for additional devices )
Design housing for DIN rail mounting
Dimensions 126 x 50 x 112.4
Electrically separated no
Housing rectangular
Input resistance 300
IO-Link revision 1.1
Key Features For the reliable limit monitoring of flow, pressure, temperature, or level; With two analog inputs; Possibility of calculating a new value based on the two input values; Various configurable monitoring functions; Monitoring data is provided via two relays and transistor outputs
Material housing: plastics
Max. current load per output 10
Max. height above sea level 4000
Max. power consumption DC 9
Max. relative air humidity 80; (31 °C; linearly decreasing to 50 % (40 °C))
Min. process cycle time 4.9
Minimum load current 10; (> 12 V)
MTTF 150
Nominal frequency AC 50...60
Nominal voltage AC 110...240
Nominal voltage DC 24
Number of Analog Inputs 2; (configurable)
Number of analog outputs 1
Number of digital outputs 2
Number of inputs and outputs Number of analog inputs: 2; Number of digital outputs: 2; Number of analog outputs: 1; Number of relay outputs: 2
Number of relay outputs 2
Operating voltage 110...240 AC / 18...30 DC; (tolerance AC operation: -20 % / +10 %)
Overvoltage category II
Pack quantity 1 pcs.
Pollution degree 2
Product type Evaluation unit for monitoring analog standard signals
Protection IP 20; (when mounted)
Protection rating terminals IP 20
Required master port class A
Resolution of analog input 12 Bit
SDCI standard IEC 61131-9
Short-circuit-proof yes
Specification Summary MONITOR; 126 x 50 x 112.4 mm; terminals
Storage Temperature -40...85
Teach function yes
Temperature coefficient ± 0,1; (> 45 °C)
Transmission type COM2 (38,4 kBaud)
Type of mounting Mounting on DIN rail; (TH35 (EN 60715))

Product details

Manufacturer IFM
Manufacturer part number DL3003
Product category Monitoring & Measuring Relays
Published specifications 51 attributes listed

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for DL3003?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the DL3003?

DL3003 is made by IFM and is listed in our Monitoring & Measuring Relays category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number DL3003, and the quote confirms condition and lead time before you order.

Is the DL3003 new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the DL3003, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of DL3003?

No published lifecycle status is on file for DL3003. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of DL3003?

Key specifications include Ambient temperature: -40...60; Analog current output: 4...20; (max.. 20,5 mA); Analog input (current): 0...20; Analog input (voltage): 0...10. The full specification table on this page lists every published attribute for this part.

What voltage does DL3003 use?

Per the published specification for DL3003: Nominal voltage AC: 110...240; Nominal voltage DC: 24. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

What material is DL3003 made of?

Per the published specification for DL3003: Material: housing: plastics. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How quickly can DL3003 ship?

Lead time for DL3003 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Frequently Searched IFM Part Numbers

Related Products

More Monitoring & Measuring Relays parts

Browse IFM part numbers starting with D ›

Technical Guides

All Electrical Control & Protection articles ›

Browse more IFM Relays & Timers, or see everything from IFM.