DL3003 IFM Evaluation unit for monitoring analog standard signals
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM DL3003 - Evaluation unit for monitoring analog standard signals - Material: housing: plastics; Storage Temperature: -40...85.
Overview
Part number DL3003 from IFM, listed in Monitoring & Measuring Relays. Specifications on file: Ambient temperature -40...60; Analog current output 4...20; (max.. 20,5 mA); Analog input (current) 0...20; Analog input (voltage) 0...10. KKM Solutions quotes this part with pricing and availability confirmed per order.
In our catalog, the DL3003 from IFM is listed under the Evaluation unit for monitoring analog standard signals category. The manufacturer's published data for this part number specifies Material: housing: plastics.
16.5...27.7; (Short-circuit proof; DC operation: ≤ 200 mA; AC operation: ≤ 150 mA)
Published specifications for this part include Storage Temperature: -40...85; Type of mounting: Mounting on DIN rail; (TH35 (EN 60715)); Ambient temperature: -40...60; Dimensions: 126 x 50 x 112.4; Number of digital outputs: 2; Application: 2-channel analog threshold relay for analog standard signals; Contact rating: 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating; B300: 6000 cycles); Pollution degree: 2; Product type: Evaluation unit for monitoring analog standard signals; Accuracy: ± 0.25; (% of the final value 45 °C 0.25 % + Temperature coefficient); Short-circuit-proof: yes; Overvoltage category: II. See the Specifications tab on this page for the full technical table.
Specifications
| Ambient temperature | -40...60 |
|---|---|
| Analog current output | 4...20; (max.. 20,5 mA) |
| Analog input (current) | 0...20 |
| Analog input (voltage) | 0...10 |
| Application | 2-channel analog threshold relay for analog standard signals |
| Auxiliary energy for sensors DC | 16.5...27.7; (Short-circuit proof; DC operation: ≤ 200 mA; AC operation: ≤ 150 mA) |
| cage clamps | ...2.5 mm² |
| Circuit | PNP |
| Communication interface | IO-Link |
| Contact rating | 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating; B300: 6000 cycles) |
| Current consumption | AC operation: max. 8 A (including maximum AC supply for additional devices ) |
| Design | housing for DIN rail mounting |
| Dimensions | 126 x 50 x 112.4 |
| Electrically separated | no |
| Housing | rectangular |
| Input resistance | 300 |
| IO-Link revision | 1.1 |
| Key Features | For the reliable limit monitoring of flow, pressure, temperature, or level; With two analog inputs; Possibility of calculating a new value based on the two input values; Various configurable monitoring functions; Monitoring data is provided via two relays and transistor outputs |
| Material | housing: plastics |
| Max. current load per output | 10 |
| Max. height above sea level | 4000 |
| Max. power consumption DC | 9 |
| Max. relative air humidity | 80; (31 °C; linearly decreasing to 50 % (40 °C)) |
| Min. process cycle time | 4.9 |
| Minimum load current | 10; (> 12 V) |
| MTTF | 150 |
| Nominal frequency AC | 50...60 |
| Nominal voltage AC | 110...240 |
| Nominal voltage DC | 24 |
| Number of Analog Inputs | 2; (configurable) |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of analog inputs: 2; Number of digital outputs: 2; Number of analog outputs: 1; Number of relay outputs: 2 |
| Number of relay outputs | 2 |
| Operating voltage | 110...240 AC / 18...30 DC; (tolerance AC operation: -20 % / +10 %) |
| Overvoltage category | II |
| Pack quantity | 1 pcs. |
| Pollution degree | 2 |
| Product type | Evaluation unit for monitoring analog standard signals |
| Protection | IP 20; (when mounted) |
| Protection rating terminals | IP 20 |
| Required master port class | A |
| Resolution of analog input | 12 Bit |
| SDCI standard | IEC 61131-9 |
| Short-circuit-proof | yes |
| Specification Summary | MONITOR; 126 x 50 x 112.4 mm; terminals |
| Storage Temperature | -40...85 |
| Teach function | yes |
| Temperature coefficient | ± 0,1; (> 45 °C) |
| Transmission type | COM2 (38,4 kBaud) |
| Type of mounting | Mounting on DIN rail; (TH35 (EN 60715)) |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | DL3003 |
| Product category | Monitoring & Measuring Relays |
| Published specifications | 51 attributes listed |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for DL3003?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the DL3003?
DL3003 is made by IFM and is listed in our Monitoring & Measuring Relays category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number DL3003, and the quote confirms condition and lead time before you order.
Is the DL3003 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the DL3003, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of DL3003?
No published lifecycle status is on file for DL3003. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of DL3003?
Key specifications include Ambient temperature: -40...60; Analog current output: 4...20; (max.. 20,5 mA); Analog input (current): 0...20; Analog input (voltage): 0...10. The full specification table on this page lists every published attribute for this part.
What voltage does DL3003 use?
Per the published specification for DL3003: Nominal voltage AC: 110...240; Nominal voltage DC: 24. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is DL3003 made of?
Per the published specification for DL3003: Material: housing: plastics. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can DL3003 ship?
Lead time for DL3003 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Frequently Searched IFM Part Numbers
Related Products
IFM Evaluation unit for level monitoring/control - DL0203
IFM Evaluation unit for level monitoring/control - DL0201
IFM evaluation unit for monitoring and converting frequency signals -…
IFM evaluation unit for monitoring and converting frequency signals -…
IFM Evaluation unit for speed monitoring - DD0203
IFM evaluation unit for monitoring and converting frequency signals -…
More Monitoring & Measuring Relays parts
Technical Guides
Browse more IFM Relays & Timers, or see everything from IFM.
Industrial Automation & MRO Parts