IFM evaluation unit for monitoring and converting frequency signals - DW3003
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

evaluation unit for monitoring and converting frequency signals - DW3003

Brand: IFM SKU: DW3003 Mfr Part #: DW3003
Ships Same Day* Worldwide Shipping

IFM DW3003 - evaluation unit for monitoring and converting frequency signals - Material: housing: plastics; Weight: 336.1; Storage Temperature: -40...85.

The IFM DW3003 is part of the evaluation unit for monitoring and converting frequency signals range in our industrial catalog. The manufacturer's published data for this part number specifies Material: housing: plastics and Weight: 336.1.

Conversion of pulse sequences into analog standard signals; pulse evaluation system for frequency, rotational speed, speed, cycles and machine cycles

Key manufacturer data on file for this item includes Storage Temperature: -40...85; Type of mounting: Mounting on DIN rail; (TH35 (EN 60715)); Ambient temperature: -40...60; Dimensions: 126 x 50 x 112.4; Number of digital inputs: 3; (1 x Frequency 1 x Reset 1 x Restart); Number of digital outputs: 2; Contact rating: 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating; B300: 6000 cycles); Pollution degree: 2; Product type: evaluation unit for monitoring and converting frequency signals; Accuracy: ± 0.2 Hz; (0.1...200 Hz); ± 0.1 % (of the measured value 200...10000 Hz)); Short-circuit-proof: yes; Overvoltage category: II. The complete technical table is shown in the Specifications tab on this page.

Accuracy ± 0.2 Hz; (0.1...200 Hz); ± 0.1 % (of the measured value 200...10000 Hz))
Ambient temperature -40...60
Analog current output 4...20; (max. 20,5 mA)
Analog voltage output 0...10
Application Conversion of pulse sequences into analog standard signals; pulse evaluation system for frequency, rotational speed, speed, cycles and machine cycles
Auxiliary energy for sensors DC 16.5...27.7; (Short-circuit proof; DC operation: ≤ 200 mA; AC operation: ≤ 150 mA)
cage clamps ...2.5 mm²
Circuit PNP
Communication interface IO-Link
Contact rating 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating; B300: 6000 cycles)
Current consumption AC operation: max. 8 A (including maximum AC supply for additional devices )
Design housing for DIN rail mounting
Dimensions 126 x 50 x 112.4
Electrically separated no
Housing rectangular
Input circuit of digital inputs PNP; (type 3 (IEC 61131-2))
Input current High 2...4
Input current low 0...1.5
IO-Link revision 1.1
Key Features Frequency-proportional current or voltage output; For detecting and monitoring frequency or speed; Various configurable monitoring functions; Monitoring data is provided via a transistor output and a relay
Material housing: plastics
Max. current load per output 10
Max. height above sea level 4000
Max. load 600; (300 Ω: Operating voltage < 24 V DC)
Max. power consumption DC 9
Max. relative air humidity 80; (31 °C; linearly decreasing to 50 % (40 °C))
Measuring range 6...900000
Min. load resistance 2000
Min. process cycle time 4.3
Minimum load current 10; (> 12 V)
Nominal frequency AC 50...60
Nominal voltage AC 110...240
Nominal voltage DC 24
Number of analog outputs 1
Number of digital inputs 3; (1 x Frequency 1 x Reset 1 x Restart)
Number of digital outputs 2
Number of inputs and outputs Number of digital inputs: 3; Number of digital outputs: 2; Number of analog outputs: 1; Number of relay outputs: 2
Number of relay outputs 2
Operating voltage 110...240 AC / 18...30 DC; (tolerance AC operation: -20 % / +10 %)
Overvoltage category II
Pack quantity 1 pcs.
Pollution degree 2
Product type evaluation unit for monitoring and converting frequency signals
Protection IP 20; (when mounted)
Protection rating terminals IP 20
Required master port class A
SDCI standard IEC 61131-9
Setting range Hz 0.1...10000
Short-circuit-proof yes
Specification Summary evaluation unit for monitoring and converting frequency signals; 126 x 50 x 112.4 mm; terminals
Storage Temperature -40...85
Switching frequency AC < 2
Switching frequency DC < 2
Switching level high 11...28
Switching level low 0...5
Transmission type COM2 (38,4 kBaud)
Type of mounting Mounting on DIN rail; (TH35 (EN 60715))
Weight 336.1

Frequently Asked Questions

How do I get pricing for DW3003?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the DW3003?

DW3003 is a IFM part. KKM Solutions sources IFM components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of DW3003?

Key specifications include Accuracy: ± 0.2 Hz; (0.1...200 Hz); ± 0.1 % (of the measured value 200...10000 Hz)); Ambient temperature: -40...60; Analog current output: 4...20; (max. 20,5 mA); Analog voltage output: 0...10. The full specification table on this page lists every published attribute for this part.

How quickly can DW3003 ship?

In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products