IFM Evaluation unit for level monitoring/control - DL0201
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Evaluation unit for level monitoring/control - DL0201

Brand: IFM SKU: DL0201 Mfr Part #: DL0201
Ships Same Day* Worldwide Shipping

IFM DL0201 - Evaluation unit for level monitoring/control - Material: housing: PC-GF20; Weight: 242.5; Storage Temperature: -25...70.

In our catalog, the DL0201 from IFM is listed under the Evaluation unit for level monitoring/control category. The manufacturer's published data for this part number specifies Material: housing: PC-GF20 and Weight: 242.5.

overflow protection (sensor with normally closed function); run-dry protection (sensor with normally open function)

Published specifications for this part include Storage Temperature: -25...70; Type of mounting: Mounting on DIN rail; (TH35 (EN 60715)); Ambient temperature: -25...60; Dimensions: 93 x 25.4 x 109; Number of digital inputs: 2; (1 x sensor signal ; 1 x Enable signal); Number of digital outputs: 1; Contact rating: 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating ; B300: 6000 cycles); Pollution degree: 2; Product type: Evaluation unit for level monitoring/control; Short-circuit-proof: yes; Overvoltage category: II; Operating voltage: 110...240 AC / 27 DC; (tolerance: -20 % / +10 % ; DC operation: SELV). See the Specifications tab on this page for the full technical table.

Ambient temperature -25...60
Application overflow protection (sensor with normally closed function); run-dry protection (sensor with normally open function)
Auxiliary energy for sensors DC 18.5...30; (SELV, Short-circuit proof , ≤ 100 mA)
cage clamps ...2.5 mm²
Circuit PNP
Contact rating 6 A; (max. 240 V AC / 30 V DC see diagram:: Contact rating ; B300: 6000 cycles)
Current consumption AC operation: max. 8 A (including maximum AC supply for additional devices )
Current rating outputs 0.1
Design housing for DIN rail mounting
Dimensions 93 x 25.4 x 109
Electrically separated no
Housing rectangular
Input circuit of digital inputs PNP; (type 2 according to IEC 61131-2)
Input current High 6...10
Input current low 0...5
Key Features Adjustable switch-on and switch-off delay; Clearly visible LEDs for indicating operation, input, output and release; protection of a tank against overflow or running dry; For the reliable wear protection of pumps and valves; Quick and time-saving rail mounting
Material housing: PC-GF20
Max. height above sea level 2000
Max. power consumption DC 4
Max. relative air humidity 80; (40 °C: 50 % non condensing)
Minimum load current 10; (> 12 V)
MTTF 200
Nominal frequency AC 50...60
Nominal voltage AC 110...240
Nominal voltage DC 27
Number of digital inputs 2; (1 x sensor signal ; 1 x Enable signal)
Number of digital outputs 1
Number of inputs and outputs Number of digital inputs: 2; Number of digital outputs: 1; Number of relay outputs: 1
Number of relay outputs 1
Operating voltage 110...240 AC / 27 DC; (tolerance: -20 % / +10 % ; DC operation: SELV)
Overvoltage category II
Pack quantity 1 pcs.
Parameter setting options setting of the input and output delay via potentiometer
Pollution degree 2
Product type Evaluation unit for level monitoring/control
Protection IP 20; (when mounted)
Protection rating terminals IP 20
Short-circuit-proof yes
Specification Summary Level control relay; overflow protection (sensor with normally closed function); run-dry protection (sensor with normally open function); Nominal voltage AC 110...240 V; Nominal voltage DC 27 V; Operating voltage 110...240 AC / 27 DC; (tolerance: -20 % / +10 % ; DC operation: SELV) V; 93 x 25.4 x 109 mm; terminals
Storage Temperature -25...70
Switching frequency AC < 0.1
Switching frequency DC < 0.1
Switching level high 11...30
Switching level low 0...5
Type of mounting Mounting on DIN rail; (TH35 (EN 60715))
Weight 242.5

Frequently Asked Questions

How do I get pricing for DL0201?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the DL0201?

DL0201 is a IFM part. KKM Solutions sources IFM components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of DL0201?

Key specifications include Ambient temperature: -25...60; Application: overflow protection (sensor with normally closed function); run-dry protection (sensor with normally open function); Auxiliary energy for sensors DC: 18.5...30; (SELV, Short-circuit proof , ≤ 100 mA); cage clamps: ...2.5 mm². The full specification table on this page lists every published attribute for this part.

How quickly can DL0201 ship?

In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products