CA80TP Endress+Hauser TP analyzer Liquiline System
KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.
Endress+Hauser CA80TP - Liquid analysis - Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F); Power Supply: 100 to 120 VAC / 200 to 240 VAC.
Overview
Part number CA80TP from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Characteristic Analyzer for total phosphorus; Measuring principle Colorimetric; Process temperature 4 to 40 °C (39.2 to 104 °F); Sample flow rate Min. 30 ml/min. KKM Solutions quotes this part with pricing and availability confirmed per order.
This listing covers the Endress+Hauser CA80TP, a part number in the Liquid analysis category. The manufacturer's published data for this part number specifies Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F) and Power Supply: 100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1,2 Hz.
Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in
Published specifications for this part include Measuring range: 0 to 2 mg/l 0.05 to 10 mg/l 0.5 to 50 mg/l; Measuring principle: Colorimetric; Process pressure: At atmospheric pressure, < 0.2 bar; Output / communication: 2x 0/4 to 20 mA Webserver, Modbus, Ethernet/IP, Profibus DP; Characteristic: Analyzer for total phosphorus; Process temperature: 4 to 40 °C (39.2 to 104 °F); Sample flow rate: Min. 30 ml/min; Consistency of the sample: Low solid content (TS<50 mg/l), homogeneous; Consumables: Reagents and standard solutions CY80TP are necessary for the operation. See the Specifications tab on this page for the full technical table.
Specifications
| Ambient temperature | 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F) |
|---|---|
| Application | Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants Monitoring of the wastewater treatment plant outlet for documentation purposes Monitoring and optimization of activated sludge basins |
| Characteristic | Analyzer for total phosphorus |
| Consumables | Reagents and standard solutions CY80TP are necessary for the operation |
| Design | Open design, cabinet and stand housing High-Performance plastic ASA-PC, additional stand coated steel |
| Input | 1 measuring channel 1 to 4 digitale sensor inputs for sensors with Memosens protocol (optional) |
| Measuring principle | Colorimetric |
| Measuring range | 0 to 2 mg/l 0.05 to 10 mg/l 0.5 to 50 mg/l |
| Output / communication | 2x 0/4 to 20 mA Webserver, Modbus, Ethernet/IP, Profibus DP |
| Power Supply | 100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1,2 Hz |
| Process temperature | 4 to 40 °C (39.2 to 104 °F) |
| Sample flow rate | Min. 30 ml/min |
| Size | Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in |
| Specials | Easy upgrade to measuring station with up to four digital Memosens sensors Automatic calibration and cleaning User-configurable measuring, cleaning and calibration intervals Self-priming analyzer with optical dosing unit l Dilution module (optional) Digital communication for remote access |
Product details
| Manufacturer | Endress+Hauser |
|---|---|
| Manufacturer part number | CA80TP |
| Product category | Vision, Measurement & Identification |
| Published specifications | 14 attributes listed |
| Related part numbers | 10 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for CA80TP?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the CA80TP?
CA80TP is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CA80TP, and the quote confirms condition and lead time before you order.
Is the CA80TP new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the CA80TP, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of CA80TP?
No published lifecycle status is on file for CA80TP. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of CA80TP?
Key specifications include Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F); Application: Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants Monitoring of the wastewater treatment plant outlet for documentation purposes Monitoring and optimization of activated sludge basins; Characteristic: Analyzer for total phosphorus; Consumables: Reagents and standard solutions CY80TP are necessary for the operation. The full specification table on this page lists every published attribute for this part.
How quickly can CA80TP ship?
Lead time for CA80TP is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other Endress+Hauser part numbers in this family:
Frequently Searched Endress+Hauser Part Numbers
Related Products
Endress+Hauser Endress+Hauser TN analyzer Liquiline System CA80TN
Endress+Hauser Endress+Hauser Low range water hardness analyzer Liquline System CA82HA
Endress+Hauser Endress+Hauser Silica analyzerLiquiline System CA80SI
Endress+Hauser Endress+Hauser STIP-scan CAM74
Endress+Hauser Endress+Hauser Orthophosphate analyzer Liquiline System CA80PH
Endress+Hauser Endress+Hauser Digital ammonium and nitrate sensor ISEmax CAS40D
Technical Guides
Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.
Industrial Automation & MRO Parts