Skip to content
Stock is confirmed when you order, and we will advise you as soon as your order is confirmed. Need help with a part? Email orderdesk@kkmsolutions.com.
Ships worldwide — lead time quoted per part (825) 454-5367 Order desk 24/7 orderdesk@kkmsolutions.com
KKM Industrial and Automation Solutions Industrial Automation & MRO Parts Line down? Call the order desk (825) 454-536724/7
Call the order desk Get a quote
Endress+Hauser Ammonium analyzerLiquiline System CA80AM

CA80AM Endress+Hauser Ammonium analyzerLiquiline System

Brand: Endress+Hauser SKU: CA80AM Mfr Part #: CA80AM

KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.

Ships worldwide — lead time quoted per part

Endress+Hauser CA80AM - Liquid analysis - Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F); Power Supply: 100 to 120 VAC / 200 to 240 VAC.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number CA80AM from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Measuring principle Colorimetric; Process pressure Unpressurized; Process temperature 4 to 40 °C (39 to 104 °F); Sample flow rate Min. 5 ml/min (0.17 fl.oz/min). KKM Solutions quotes this part with pricing and availability confirmed per order.

Endress+Hauser CA80AM is a Liquid analysis catalog item from Endress+Hauser. The manufacturer's published data for this part number specifies Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F) and Power Supply: 100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1.2 Hz.

Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in

Key manufacturer data on file for this item includes Measuring principle: Colorimetric; Process pressure: Unpressurized; Output / communication: 2x 0/4 to 20 mA Optional: Webserver, Modbus, Ethernet/IP, Profibus DP; Characteristic: Analyzer for ammonium in aqueous solutions; Process temperature: 4 to 40 °C (39 to 104 °F); Sample flow rate: Min. 5 ml/min (0.17 fl.oz/min); Consistency of the sample: Low solids content Turbitity < 50 NTU, aqueous, homogenized; Consumables: Reagents and standard solutions CY80AM Cleaner CY800 Maintenance kit CAV800. The complete technical table is shown in the Specifications tab on this page.

Specifications

Ambient temperature 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F)
Application Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants Monitoring of the wastewater treatment plant outlet for documentation purposes Monitoring and optimization of activated sludge basins
Characteristic Analyzer for ammonium in aqueous solutions
Consumables Reagents and standard solutions CY80AM Cleaner CY800 Maintenance kit CAV800
Design Open design / cabinet: Plastic ASA-PC Stand housing: Plastic ASA-PC, steel coated
Input 1 or 2 measuring channels Optinonal 1 to 4 digital sensor inputs for sensors with Memosens protocol
Measuring method Comply with standard colorimetric measuring principle - indophenol blue method following ISO 7150-1, DIN 38406-5 and GB 7481-87
Measuring principle Colorimetric
Measuring range 0.05 to 20 mg/l NH4-N 0.5 to 50 mg/l NH4-N 1 to 100 mg/l NH4-N 0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l NH4-N
Output / communication 2x 0/4 to 20 mA Optional: Webserver, Modbus, Ethernet/IP, Profibus DP
Power Supply 100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1.2 Hz
Process pressure Unpressurized
Process temperature 4 to 40 °C (39 to 104 °F)
Sample flow rate Min. 5 ml/min (0.17 fl.oz/min)
Size Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in
Specials Easy upgrade to measuring station with up to four digital Memosens sensors Automatic calibration and cleaning User-configurable measuring, cleaning and calibration intervals Optional cooling module for longer reagent life time Automatic calibration and cleaning Optional 2 channel version User-definable measuring ranges Flexibale functionality and modular expandable Digital communication for remote access

Product details

Manufacturer Endress+Hauser
Manufacturer part number CA80AM
Product category Vision, Measurement & Identification
Published specifications 16 attributes listed
Related part numbers 10 other part numbers in this family

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for CA80AM?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the CA80AM?

CA80AM is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CA80AM, and the quote confirms condition and lead time before you order.

Is the CA80AM new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the CA80AM, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of CA80AM?

No published lifecycle status is on file for CA80AM. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of CA80AM?

Key specifications include Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F); Application: Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants Monitoring of the wastewater treatment plant outlet for documentation purposes Monitoring and optimization of activated sludge basins; Characteristic: Analyzer for ammonium in aqueous solutions; Consumables: Reagents and standard solutions CY80AM Cleaner CY800 Maintenance kit CAV800. The full specification table on this page lists every published attribute for this part.

How quickly can CA80AM ship?

Lead time for CA80AM is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Variants & Related Part Numbers

Other Endress+Hauser part numbers in this family:

Frequently Searched Endress+Hauser Part Numbers

Related Products

Technical Guides

All Sensors & Measurement articles ›

Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.