Endress+Hauser CA80FE - Liquid analysis - Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F); Power Supply: 100 to 120 VAC / 200 to 240 VAC.
Overview
Part number CA80FE from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Measuring principle Colorimetric; Process temperature 4 to 40 °C (39.2 to 104 °F); Sample flow rate Min. 5 ml/min (0.17 fl.oz/min). KKM Solutions quotes this part with pricing and availability confirmed per order.
This listing covers the Endress+Hauser CA80FE, a part number in the Liquid analysis category. The manufacturer's published data for this part number specifies Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F) and Power Supply: 100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1,2 Hz.
Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in
Published specifications for this part include Measuring principle: Colorimetric; Process pressure: At atmospheric pressure, < 0.2 bar; Output / communication: 2x 0/4 to 20 mA Webserver, Modbus, Ethernet/IP, Profibus DP; Process temperature: 4 to 40 °C (39.2 to 104 °F); Sample flow rate: Min. 5 ml/min (0.17 fl.oz/min); Consistency of the sample: Suspended solids content Turbitity < 50 NTU, aqueous, homogenized. The complete technical table is shown in the Specifications tab on this page.
Specifications
| Ambient temperature | 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F) |
|---|---|
| Application | Monitoring of the iron content of potable water, mineral water and source water for industrial processes |
| Characteristic | Process analyzer for iron in aqueous solutions Comply with standard colorimetric measuring principle, ferrozine method |
| Consumables | Reagents and standard solutions CY80FE for the operation Regular maintenance is done with the parts of the maintenance kit CAV800 |
| Design | Open design, cabinet and stand housing High-Performance plastic ASA-PC, additional stand coated steel |
| Input | 1 or 2 measuring channel 1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) |
| Measuring principle | Colorimetric |
| Measuring range | 0.05 to 2 mg/l Fe 0.1 to 5 mg/l Fe 0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe |
| Output / communication | 2x 0/4 to 20 mA Webserver, Modbus, Ethernet/IP, Profibus DP |
| Power Supply | 100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1,2 Hz |
| Process temperature | 4 to 40 °C (39.2 to 104 °F) |
| Sample flow rate | Min. 5 ml/min (0.17 fl.oz/min) |
| Size | Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in |
Product details
| Manufacturer | Endress+Hauser |
|---|---|
| Manufacturer part number | CA80FE |
| Product category | Vision, Measurement & Identification |
| Published specifications | 13 attributes listed |
| Related part numbers | 10 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for CA80FE?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the CA80FE?
CA80FE is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CA80FE, and the quote confirms condition and lead time before you order.
Is the CA80FE new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the CA80FE, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of CA80FE?
No published lifecycle status is on file for CA80FE. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of CA80FE?
Key specifications include Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F); Application: Monitoring of the iron content of potable water, mineral water and source water for industrial processes; Characteristic: Process analyzer for iron in aqueous solutions Comply with standard colorimetric measuring principle, ferrozine method; Consumables: Reagents and standard solutions CY80FE for the operation Regular maintenance is done with the parts of the maintenance kit CAV800. The full specification table on this page lists every published attribute for this part.
How quickly can CA80FE ship?
Lead time for CA80FE is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other Endress+Hauser part numbers in this family:
Frequently Searched Endress+Hauser Part Numbers
Related Products
Endress+Hauser Endress+Hauser Chromate analyzer Liquiline System CA80CR
Endress+Hauser Endress+Hauser Water hardness analyzerLiquiline System CA80HA
Endress+Hauser Endress+Hauser COD analyzer Liquiline System CA80COD
Endress+Hauser Endress+Hauser Nitrite analyzer Liquiline System CA80NO
Endress+Hauser Endress+Hauser Ammonium analyzerLiquiline System CA80AM
Endress+Hauser Endress+Hauser Orthophosphate analyzer Liquiline System CA80PH
Technical Guides
Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.
Industrial Automation & MRO Parts