Endress+Hauser Nitrite analyzer Liquiline System CA80NO

CA80NO Endress+Hauser Nitrite analyzer Liquiline System

Brand: Endress+Hauser SKU: CA80NO Mfr Part #: CA80NO

KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.

Ships worldwide — lead time quoted per part

Endress+Hauser CA80NO - Liquid analysis - Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F); Power Supply: 100 to 120 VAC / 200 to 240 VAC.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number CA80NO from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Measuring principle Colorimetric; Process temperature 4 to 40 °C (39 to 104 °F); Sample flow rate Min. 5 ml/min (0.17 fl.oz/min). KKM Solutions quotes this part with pricing and availability confirmed per order.

Endress+Hauser CA80NO is a Liquid analysis catalog item from Endress+Hauser. The manufacturer's published data for this part number specifies Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F) and Power Supply: 100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1,2 Hz.

Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in

Published specifications for this part include Measuring principle: Colorimetric; Process pressure: At atmospheric pressure, < 0.2 bar absolute; Output / communication: 2x 0/4 to 20 mA Modbus RS485/TCP (optional) Ethernet (optional) Alarmrelay; Characteristic: Process analyzer for Nitrite in potable water; Process temperature: 4 to 40 °C (39 to 104 °F); Sample flow rate: Min. 5 ml/min (0.17 fl.oz/min); Consistency of the sample: Suspended solids content Turbitity < 50 NTU, aqueous, homogenized. See the Specifications tab on this page for the full technical table.

Specifications

Ambient temperature 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F)
Application Limit value monitoring of nitrite for potable water and mineral water applications
Characteristic Process analyzer for Nitrite in potable water
Consumables Reagents and standard solutions CY80NO as well as cleaner CY800 are necessary for the operation Regular maintenance is done with the parts of the maintenance kit CAV800
Design Open design, cabinet and stand housing High-Performance plastic ASA-PC, additional stand coated steel
Input 1 or 2 measuring channel 1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)
Measuring principle Colorimetric
Measuring range 10 to 500 µg/l NO2-N 0.2 to 3.0 mg/l NO2-N 0.1 to 1.0 mg/l NO2-N 0.1 to 1.0 mg/l with dilution function to maximum 5 to 50 mg/l NO2-N
Output / communication 2x 0/4 to 20 mA Modbus RS485/TCP (optional) Ethernet (optional) Alarmrelay
Power Supply 100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1,2 Hz
Process temperature 4 to 40 °C (39 to 104 °F)
Sample flow rate Min. 5 ml/min (0.17 fl.oz/min)
Size Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in
Specials Easy upgrade to measuring station with up to four digital Memosens sensors Automatic calibration and cleaning User-configurable measuring, cleaning and calibration intervals Optional cooling module for standard solution 2 channel version optional User-definable measuring ranges Modular design for easily extensible functionality

Product details

Manufacturer Endress+Hauser
Manufacturer part number CA80NO
Product category Vision, Measurement & Identification
Published specifications 14 attributes listed
Related part numbers 10 other part numbers in this family

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for CA80NO?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the CA80NO?

CA80NO is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CA80NO, and the quote confirms condition and lead time before you order.

Is the CA80NO new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the CA80NO, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of CA80NO?

No published lifecycle status is on file for CA80NO. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of CA80NO?

Key specifications include Ambient temperature: 5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F); Application: Limit value monitoring of nitrite for potable water and mineral water applications; Characteristic: Process analyzer for Nitrite in potable water; Consumables: Reagents and standard solutions CY80NO as well as cleaner CY800 are necessary for the operation Regular maintenance is done with the parts of the maintenance kit CAV800. The full specification table on this page lists every published attribute for this part.

How quickly can CA80NO ship?

Lead time for CA80NO is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.