IFM SD8100 - industrial gas counter - Storage Temperature: -20...85; Display range: 0...440.
Overview
Part number SD8100 from IFM, listed in Counters & Rate Meters. Specifications on file: Ambient temperature 0...60; Analog current output 4...20; (scalable); Analog end point 12...60; Analog end point AEP 73.4...366.6. KKM Solutions quotes this part with pricing and availability confirmed per order.
The IFM SD8100 is part of the industrial gas counter range in our industrial catalog. The manufacturer's published data for this part number specifies Weight: 2029 and Storage Temperature: -20...85.
PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminum powder-coated
Key manufacturer data on file for this item includes Display range: 0...440; Ambient temperature: 0...60; Connector: 1 x M12; coding: A; Contacts: 4; Protection class: III; Dimensions: 475 x 45 x 88.5; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: industrial gas counter; Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Response time: 0.1; (dAP = 0); Communication interface: IO-Link. See the Specifications tab on this page for the full technical table.
Specifications
| Accuracy | ± 2; (medium flow in the limit area of the flow measurement range) |
|---|---|
| Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN25) |
| Ambient temperature | 0...60 |
| Analog current output | 4...20; (scalable) |
| Analog end point | 12...60 |
| Analog end point AEP | 73.4...366.6 |
| Analog start point | 0...48 |
| Analog start point ASP | 0...293.2 |
| Application | for industrial applications |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4 |
| Damping process value dAP in steps | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
| Dimensions | 475 x 45 x 88.5 |
| Display range | 0...440 |
| Display unit | Nl/min; Nm³/h; Nm³; °C |
| Electrical design | PNP |
| In steps of | 0.2 |
| IO-Link revision | 1.1 |
| Key Features | Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2); With switching output, analog output and pulse output; Clearly visible numerical display |
| Material | PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminum powder-coated |
| Materials (wetted parts) | stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK-GF30; polyester; aluminum |
| Max. load | 500 |
| Max. relative air humidity | 90 |
| Max. voltage drop switching output DC | 2 |
| Measuring range | 1.2...366.6 |
| Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
| Medium temperature | 0...60 |
| Min. process cycle time | 4.1 |
| MTTF | 224 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 18...30 DC |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection |
| Permanent current rating of switching output DC | 250; (per output) |
| Power-on delay time | 1 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Process Connection | threaded connection R 1 external thread DN25 |
| Process data analog | 3 |
| Process data binary | 2 |
| Product type | industrial gas counter |
| Protection | IP 65 |
| Protection class | III |
| Pulse length | 0,004...2 |
| Pulse output | consumed quantity meter |
| Pulse value | 0.001...3 000 000 Nm³ |
| Repeatability | ± 1,5 |
| Required master port class | A |
| Reset point rP | 1.8...365 |
| Resolution | 0.2 |
| Response time | 0.1; (dAP = 0) |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 |
| Set point SP | 3.4...366.6 |
| Short circuit protection | yes |
| SIO mode | yes |
| Specification Summary | industrial gas counter; PNP; switching signal; analog signal; pulse signal; IO-Link; Measuring range (CO2 / N2 / Ar) 0.8...223.6 m³/h / 0.8...225 m³/h / 1.2...366.6 m³/h; Medium temperature 0...60 °C; Pressure rating 16 bar; R 1 external thread DN25; Connector |
| Storage Temperature | -20...85 |
| Total number of outputs | 2 |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | yes (non-latching) |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | SD8100 |
| Product category | Counters & Rate Meters |
| Published specifications | 65 attributes listed |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for SD8100?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SD8100?
SD8100 is made by IFM and is listed in our Counters & Rate Meters category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SD8100, and the quote confirms condition and lead time before you order.
Is the SD8100 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the SD8100, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of SD8100?
No published lifecycle status is on file for SD8100. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of SD8100?
Key specifications include Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN25); Ambient temperature: 0...60; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
What voltage does SD8100 use?
Per the published specification for SD8100: Max. voltage drop switching output DC: 2; Operating voltage: 18...30 DC. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of SD8100?
Per the published specification for SD8100: Permanent current rating of switching output DC: 250; (per output). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is SD8100 made of?
Per the published specification for SD8100: Material: PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminum powder-coated. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can SD8100 ship?
Lead time for SD8100 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Frequently Searched IFM Part Numbers
Related Products
IFM industrial gas counter - SD6800
IFM industrial gas counter - SD8600
IFM industrial gas counter - SD6601
IFM industrial gas counter - SD8601
IFM industrial gas counter - SD6600
IFM industrial gas counter - SD6101
More Counters & Rate Meters parts