SD6601 IFM industrial gas counter
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM SD6601 - industrial gas counter - Storage Temperature: -4...185; Display range: -15...290.
Overview
Part number SD6601 from IFM, listed in Counters & Rate Meters. Specifications on file: Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); Ambient temperature 32...140; Analog current output 4...20; (scalable); Analog end point 32...232. KKM Solutions quotes this part with pricing and availability confirmed per order.
This listing covers the IFM SD6601, a part number in the industrial gas counter category. The manufacturer's published data for this part number specifies Storage Temperature: -4...185.
PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM
The specification set recorded for this part number covers Display range: -15...290; Ambient temperature: 32...140; Connector: 1 x M12; coding: A; Contacts: 4; Protection class: III; Dimensions: 300 x 45.4 x 71.2; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: industrial gas counter; Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Response time: < 0.1; (dAP = 0, T09); Communication interface: IO-Link. The complete technical table is shown in the Specifications tab on this page.
Specifications
| Accuracy | ± 0,5; (medium flow in the limit area of the flow measurement range) |
|---|---|
| Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW) |
| Ambient temperature | 32...140 |
| Analog current output | 4...20; (scalable) |
| Analog end point | 32...232 |
| Analog start point | -15...186 |
| Application | for industrial applications |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4 |
| Damping process value dAP | 0...5 |
| Dimensions | 300 x 45.4 x 71.2 |
| Display range | -15...290 |
| Dynamic response T05 / T09 | T09 = 0,5 |
| Electrical design | PNP/NPN |
| Greatest TEMPCO of the span | ± 0,3 |
| Greatest TEMPCO of the zero point | ± 0,1 |
| Housing | rectangular |
| In steps of | 1 |
| Inputs | counter reset |
| IO-Link revision | 1.1 |
| Key Features | Precise measurement of flow, consumption, pressure and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2) and compressed air; Red/green display for clear identification of the acceptable range; Display can be rotated for optimum alignment |
| Material | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM |
| Materials (wetted parts) | stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
| MAWP (for applications according to CRN) | 9.7 |
| Max. load | 500 |
| Max. relative air humidity | 90 |
| Max. voltage drop switching output DC | 2.5 |
| Measuring range | -15...232 |
| Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air |
| Medium temperature | 14...140 |
| Min. burst pressure | 928 |
| Min. process cycle time | 7.2 |
| MTTF | 183 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 18...30 DC; (to SELV/PELV) |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer |
| Permanent current rating of switching output DC | 150; (per output) |
| Power-on delay time | 1 |
| Pressure equipment directive | sound engineering practice; can be used for stable gases fluid group 2 |
| Pressure Rating | 232 |
| Process Connection | threaded connection 1/2" NPT external thread DN15 |
| Process data analog | 8 |
| Process data binary | 2 |
| Product type | industrial gas counter |
| Protection | IP 65; IP 67 |
| Protection class | III |
| Pulse length | 0.002...2 |
| Pulse output | consumed quantity meter |
| Repeatability | ± (0,4 % MW + 0,1 % MEW) |
| Required master port class | A |
| Reset point rP | -15...231 |
| Resolution | 1 |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 CDV |
| Set point SP | -13...232 |
| Short circuit protection | yes |
| SIO mode | yes |
| Specification Summary | industrial gas counter; PNP/NPN; switching signal; analog signal; pulse signal; IO-Link; 1/2" NPT external thread DN15; Connector |
| Storage Temperature | -4...185 |
| Temperature coefficient | ± 0,07 % MW |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | yes (non-latching) |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | SD6601 |
| Product category | Counters & Rate Meters |
| Published specifications | 68 attributes listed |
| Related part numbers | 1 other part number in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for SD6601?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SD6601?
SD6601 is made by IFM and is listed in our Counters & Rate Meters category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SD6601, and the quote confirms condition and lead time before you order.
Is the SD6601 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the SD6601, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of SD6601?
No published lifecycle status is on file for SD6601. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of SD6601?
Key specifications include Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): ± (6 % MW + 0,6 % MEW); Ambient temperature: 32...140; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
What voltage does SD6601 use?
Per the published specification for SD6601: Max. voltage drop switching output DC: 2.5; Operating voltage: 18...30 DC; (to SELV/PELV). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of SD6601?
Per the published specification for SD6601: Permanent current rating of switching output DC: 150; (per output). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is SD6601 made of?
Per the published specification for SD6601: Material: PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can SD6601 ship?
Lead time for SD6601 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other IFM part numbers in this family:
Frequently Searched IFM Part Numbers
Related Products
IFM industrial gas counter - SD6600
IFM industrial gas counter - SD6800
IFM industrial gas counter - SD6101
IFM industrial gas counter - SD8100
IFM industrial gas counter - SD6100
IFM industrial gas counter - SD8600
More Counters & Rate Meters parts
Technical Guides
Browse more IFM Instrumentation & Test, or see everything from IFM.
Industrial Automation & MRO Parts