SD5100 IFM industrial gas counter
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM SD5100 - industrial gas counter - Material: PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM; Storage Temperature: -20...85.
Overview
Part number SD5100 from IFM, listed in Counters & Rate Meters. Specifications on file: Ambient temperature 0...60; Analog current output 4...20; (scalable); Analog end point 12...60; Analog end point AEP 4.8...24.04. KKM Solutions quotes this part with pricing and availability confirmed per order.
This listing covers the IFM SD5100, a part number in the industrial gas counter category. The manufacturer's published data for this part number specifies Material: PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM.
Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting compressed air in industrial use; With switching output, analog output and pulse output; Clearly visible numerical display
The specification set recorded for this part number covers Storage Temperature: -20...85; Display range: 0...28.84; Ambient temperature: 0...60; Connector: 1 x M12; coding: A; Contacts: 4; Protection class: III; Dimensions: 182.3 x 45 x 74.5; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: industrial gas counter; Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Response time: 0.1; (dAP = 0). The complete technical table is shown in the Specifications tab on this page.
Specifications
| Accuracy | ± 2; (medium flow in the limit area of the flow measurement range) |
|---|---|
| Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533) |
| Ambient temperature | 0...60 |
| Analog current output | 4...20; (scalable) |
| Analog end point | 12...60 |
| Analog end point AEP | 4.8...24.04 |
| Analog start point | 0...48 |
| Analog start point ASP | 0...19.24 |
| Application | for industrial applications |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4 |
| Damping process value dAP in steps | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
| Dimensions | 182.3 x 45 x 74.5 |
| Display range | 0...28.84 |
| Display unit | Nl/min; Nm³/h; Nm³; °C |
| Electrical design | PNP |
| Housing | rectangular |
| In steps of | 0.02 |
| IO-Link revision | 1.1 |
| Key Features | Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting compressed air in industrial use; With switching output, analog output and pulse output; Clearly visible numerical display |
| Material | PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM |
| Materials (wetted parts) | stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminum anodized |
| Max. load | 500 |
| Max. relative air humidity | 90 |
| Max. voltage drop switching output DC | 2 |
| Measuring dynamics | 1:300 |
| Measuring range | 0.08...24.04 |
| Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
| Medium temperature | 0...60 |
| Min. process cycle time | 4.1 |
| MTTF | 227 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 18...30 DC; (to SELV/PELV) |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection |
| Permanent current rating of switching output DC | 250; (per output) |
| Power-on delay time | 1 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Process Connection | threaded connection G 1/4 Internal thread DN8 |
| Process data analog | 3 |
| Process data binary | 2 |
| Product type | industrial gas counter |
| Protection | IP 65 |
| Protection class | III |
| Pulse length | 0,062...2 |
| Pulse output | consumed quantity meter |
| Pulse value | 0.001...1 000 000 m³ |
| Repeatability | ± 1,5 |
| Required master port class | A |
| Reset point rP | 0.12...23.94 |
| Resolution | 0.02 |
| Response time | 0.1; (dAP = 0) |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 |
| Set point SP | 0.22...24.04 |
| Short circuit protection | yes |
| SIO mode | yes |
| Specification Summary | industrial gas counter; PNP; switching signal; analog signal; pulse signal; IO-Link; Measuring range (CO2 / N2 / Ar) 0.04...14.36 m³/h / 0.04...15 m³/h / 0.08...24.04 m³/h; Medium temperature 0...60 °C; Pressure rating 16 bar; G 1/4 Internal thread DN8; Connector |
| Storage Temperature | -20...85 |
| Total number of outputs | 2 |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | yes (non-latching) |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | SD5100 |
| Product category | Counters & Rate Meters |
| Published specifications | 67 attributes listed |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for SD5100?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SD5100?
SD5100 is made by IFM and is listed in our Counters & Rate Meters category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SD5100, and the quote confirms condition and lead time before you order.
Is the SD5100 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the SD5100, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of SD5100?
No published lifecycle status is on file for SD5100. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of SD5100?
Key specifications include Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533); Ambient temperature: 0...60; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
What voltage does SD5100 use?
Per the published specification for SD5100: Max. voltage drop switching output DC: 2; Operating voltage: 18...30 DC; (to SELV/PELV). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of SD5100?
Per the published specification for SD5100: Permanent current rating of switching output DC: 250; (per output). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is SD5100 made of?
Per the published specification for SD5100: Material: PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can SD5100 ship?
Lead time for SD5100 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Frequently Searched IFM Part Numbers
Related Products
IFM industrial gas counter - SD5600
IFM industrial gas counter - SD5800
IFM industrial gas counter - SD6100
IFM industrial gas counter - SD6101
IFM industrial gas counter - SD6600
IFM industrial gas counter - SD6601
More Counters & Rate Meters parts
Technical Guides
Browse more IFM Instrumentation & Test, or see everything from IFM.
Industrial Automation & MRO Parts