Compressed air meter - SD5500
IFM SD5500 - Compressed air meter - Weight: 556; Storage Temperature: -20...85; Display range: -1...20.
The IFM SD5500 is part of the Compressed air meter range in our industrial catalog. The manufacturer's published data for this part number specifies Weight: 556 and Storage Temperature: -20...85.
PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM
Published specifications for this part include Display range: -1...20; Ambient temperature: 0...60; Connector: 1 x M12; coding: A; Contacts: 4; Protection class: III; Dimensions: 182 x 45.4 x 67.8; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: Compressed air meter; Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Response time: < 0.1; (dAP = 0, T09); Communication interface: IO-Link. The complete technical table is shown in the Specifications tab on this page.
| Accuracy | ± 0,5; (medium flow in the limit area of the flow measurement range) |
|---|---|
| Accuracy (in the measuring range) | class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 23 °C |
| Ambient temperature | 0...60 |
| Analog current output | 4...20; (scalable) |
| Analog end point | 2.2...16 |
| Analog start point | -1...12.8 |
| Application | for industrial applications |
| Characteristics deviation | < ± 0,5; (BFSL = Best Fit Straight Line) |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4 |
| Current consumption | < 80 |
| Damping process value dAP | 0...5 |
| Dimensions | 182 x 45.4 x 67.8 |
| Display range | -1...20 |
| Dynamic response T05 / T09 | T09 = 0,5 |
| Electrical design | PNP/NPN |
| Greatest TEMPCO of the span | ± 0,3 |
| Greatest TEMPCO of the zero point | ± 0,1 |
| Housing | rectangular |
| In steps of | 0.01 |
| Inputs | counter reset |
| IO-Link revision | 1.1 |
| Key Features | Precise measurement of flow, consumption, pressure and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting compressed air in industrial use; Red/green display for clear identification of the acceptable range; Display can be rotated for optimum alignment |
| Material | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM |
| Materials (wetted parts) | EN AW-6082 (aluminium); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
| MAWP (for applications according to CRN) | 9.5 |
| Max. load | 500 |
| Max. relative air humidity | 90 |
| Max. voltage drop switching output DC | 2.5 |
| Measuring range | -1...16 |
| Media | compressed air |
| Medium temperature | -10...60 |
| Min. process cycle time | 7.2 |
| MTTF | 183 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 18...30 DC; (to SELV/PELV) |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer |
| Permanent current rating of switching output DC | 150; (per output) |
| Power-on delay time | 1 |
| Pressure equipment directive | sound engineering practice; can be used for stable gases fluid group 2 |
| Process Connection | threaded connection G 1/4 Internal thread DN8 |
| Process data analog | 8 |
| Process data binary | 2 |
| Product type | Compressed air meter |
| Protection | IP 65; IP 67 |
| Protection class | III |
| Pulse length | 0.01...2 |
| Pulse output | consumed quantity meter |
| Repeatability | ± (0,4 % MW + 0,1 % MEW) |
| Required master port class | A |
| Reset point rP | -1...15.92 |
| Resolution | 0.05 |
| Response time | < 0.1; (dAP = 0, T09) |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 CDV |
| Set point SP | -0.92...16 |
| Short circuit protection | yes |
| SIO mode | yes |
| Specification Summary | Compressed air meter; PNP/NPN; switching signal; analog signal; pulse signal; IO-Link; Measuring range 0.05...15 m³/h; Measuring range 0.8...250 l/min; Medium temperature -10...60 °C; Pressure rating 16 bar; G 1/4 Internal thread DN8; Connector |
| Storage Temperature | -20...85 |
| Temperature coefficient | ± 0,07 % MW |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | yes (non-latching) |
| Weight | 556 |
Frequently Asked Questions
How do I get pricing for SD5500?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SD5500?
SD5500 is a IFM part. KKM Solutions sources IFM components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of SD5500?
Key specifications include Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): class 141: ± (2 % MW + 0,5 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 23 °C; Ambient temperature: 0...60; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
How quickly can SD5500 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
IFM Compressed air meter - SD5000
IFM Compressed air meter - SD6000
IFM Compressed air meter - SD2501
IFM Compressed air meter - SD6020
IFM Compressed air meter - SD2500
IFM
Industrial & MRO Parts