SD6020 IFM Compressed air meter
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM SD6020 - Compressed air meter - Storage Temperature: -20...85; Ambient temperature: 0...60.
Overview
Part number SD6020 from IFM, listed in Pneumatics. Specifications on file: Ambient temperature 0...60; Analog current output 4...20; (scalable); Application for industrial applications; Communication interface IO-Link. KKM Solutions quotes this part with pricing and availability confirmed per order.
In our catalog, the SD6020 from IFM is listed under the Compressed air meter category. The manufacturer's published data for this part number specifies Storage Temperature: -20...85.
PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM
Key manufacturer data on file for this item includes Ambient temperature: 0...60; Connector: 1 x M12; coding: A; Contacts: 4; Protection class: III; Dimensions: 150 x 45.4 x 71.2; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: Compressed air meter; Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Response time: < 0.1; (dAP = 0, T09); Communication interface: IO-Link; Operating voltage: 18...30 DC; (to SELV/PELV). See the Specifications tab on this page for the full technical table.
Specifications
| Accuracy | ± 0,5; (medium flow in the limit area of the flow measurement range) |
|---|---|
| Accuracy (in the measuring range) | ± (15 % MW + 1,5 % MEW); (maximum value to be achieved for air quality class 344 (DIN8573-1:2010); when using pipes of tolerance class T3/T4; inlet and outlet pipe lengths without edges and abrupt diameter changes; inner surface of the pipe free of burrs) |
| Ambient temperature | 0...60 |
| Analog current output | 4...20; (scalable) |
| Application | for industrial applications |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4 |
| Damping process value dAP | 0...5 |
| Dimensions | 150 x 45.4 x 71.2 |
| Dynamic response T05 / T09 | T09 = 0,5 |
| Electrical design | PNP/NPN |
| Housing | rectangular |
| Inputs | counter reset |
| IO-Link revision | 1.1 |
| Key Features | Precise measurement of flow, consumption and medium temperature; High repeatability and measurement dynamics; For detecting compressed air in industrial use; Red/green display for clear identification of the acceptable range; Display can be rotated for optimum alignment |
| Material | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM |
| Materials (wetted parts) | stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; acrylate |
| MAWP (for applications according to CRN) | 16 |
| Max. load | 500 |
| Max. relative air humidity | 90 |
| Max. voltage drop switching output DC | 2.5 |
| Media | compressed air |
| Medium temperature | -10...60 |
| Min. process cycle time | 5.9 |
| MTTF | 195 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 18...30 DC; (to SELV/PELV) |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer |
| Permanent current rating of switching output DC | 150; (per output) |
| Power-on delay time | 1 |
| Pressure equipment directive | sound engineering practice; can be used for stable gases fluid group 2 |
| Process Connection | threaded connection R 1/2 external thread DN15 |
| Process data analog | 6 |
| Process data binary | 2 |
| Product type | Compressed air meter |
| Protection | IP 65; IP 67 |
| Protection class | III |
| Pulse length | 0.002...2 |
| Pulse output | consumed quantity meter |
| Repeatability | ± 1,5 % MW |
| Required master port class | A |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 CDV |
| Short circuit protection | yes |
| SIO mode | yes |
| Specification Summary | Compressed air meter; PNP/NPN; switching signal; analog signal; pulse signal; IO-Link; Measuring range 0.25...75 m³/h; Measuring range 4...1250 l/min; Medium temperature -10...60 °C; Pressure rating 16 bar; R 1/2 external thread DN15; Connector |
| Storage Temperature | -20...85 |
| Temperature coefficient | ± 0,07 % MW |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | yes (non-latching) |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | SD6020 |
| Product category | Pneumatics |
| Published specifications | 56 attributes listed |
| Related part numbers | 3 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for SD6020?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SD6020?
SD6020 is made by IFM and is listed in our Pneumatics category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SD6020, and the quote confirms condition and lead time before you order.
Is the SD6020 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the SD6020, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of SD6020?
No published lifecycle status is on file for SD6020. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of SD6020?
Key specifications include Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): ± (15 % MW + 1,5 % MEW); (maximum value to be achieved for air quality class 344 (DIN8573-1:2010); when using pipes of tolerance class T3/T4; inlet and outlet pipe lengths without edges and abrupt diameter changes; inner surface of the pipe free of burrs); Ambient temperature: 0...60; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
What voltage does SD6020 use?
Per the published specification for SD6020: Max. voltage drop switching output DC: 2.5; Operating voltage: 18...30 DC; (to SELV/PELV). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of SD6020?
Per the published specification for SD6020: Permanent current rating of switching output DC: 150; (per output). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is SD6020 made of?
Per the published specification for SD6020: Material: PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can SD6020 ship?
Lead time for SD6020 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other IFM part numbers in this family:
Frequently Searched IFM Part Numbers
Related Products
IFM Compressed air meter - SD6000
IFM Compressed air meter - SD6050
IFM Compressed air meter - SD5500
IFM Compressed air meter - SD6500
IFM Compressed air meter - SD6501
IFM Compressed air meter - SD5000
Technical Guides
Browse more IFM Pneumatics, or see everything from IFM.
Industrial Automation & MRO Parts