IFM Compressed air meter - SD2001

SD2001 IFM Compressed air meter

Brand: IFM SKU: SD2001 Mfr Part #: SD2001

KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.

Ships worldwide — lead time quoted per part

IFM SD2001 - Compressed air meter - Storage Temperature: -4...185; Display range: 32...140.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number SD2001 from IFM, listed in Pneumatics. Specifications on file: Ambient temperature 32...140; Analog current output 4...20; (scalable); Application for industrial applications; Connector 1 x M12; coding: A; Contacts: 4. KKM Solutions quotes this part with pricing and availability confirmed per order.

IFM SD2001 is a Compressed air meter catalog item from IFM. The manufacturer's published data for this part number specifies Storage Temperature: -4...185.

PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminum powder-coated

Published specifications for this part include Display range: 32...140; Ambient temperature: 32...140; Connector: 1 x M12; coding: A; Contacts: 4; Protection class: III; Dimensions: 475 x 100 x 133; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; (configurable); Product type: Compressed air meter; Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Response time: 0.1; (dAP = 0); Measuring range: 32...140. See the Specifications tab on this page for the full technical table.

Specifications

Accuracy ± 2; (medium flow in the limit area of the flow measurement range)
Accuracy (in the measuring range) ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN50)
Ambient temperature 32...140
Analog current output 4...20; (scalable)
Application for industrial applications
Connector 1 x M12; coding: A; Contacts: 4
Damping process value dAP in steps 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Dimensions 475 x 100 x 133
Display range 32...140
Electrical design PNP
Housing rectangular
In steps of 0.020...1000 scf
Key Features Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting compressed air in industrial use; With switching output, analog output and pulse output; Clearly visible numerical display
Material PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminum powder-coated
Materials (wetted parts) stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminum
MAWP (for applications according to CRN) 16
Max. load 500
Max. relative air humidity 90
Max. voltage drop switching output DC 2
Measuring range 32...140
Media compressed air
Medium temperature 32...140
MTTF 227
Number of analog outputs 1
Number of digital outputs 2
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Operating voltage 19...30 DC; (to SELV/PELV)
Output function normally open / closed; (configurable)
Output signal switching signal; analog signal; pulse signal; (configurable)
Overload protection yes
Pack quantity 1 pcs.
Parameter setting options Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit
Permanent current rating of switching output DC 250; (per output)
Power-on delay time 0.5
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Process Connection threaded connection 2" NPT external thread DN50
Product type Compressed air meter
Protection IP 65
Protection class III
Pulse length 0,049... 2
Pulse output consumed quantity meter
Pulse value 0.400...4 000 000 scf
Repeatability ± 1,5
Response time 0.1; (dAP = 0)
Reverse polarity protection yes
Short circuit protection yes
Specification Summary Compressed air meter; PNP; switching signal; analog signal; pulse signal; Pressure rating 16 bar; 2" NPT external thread DN50; Connector
Storage Temperature -4...185
Total number of outputs 2
Type of short-circuit protection yes (non-latching)

Product details

Manufacturer IFM
Manufacturer part number SD2001
Product category Pneumatics
Published specifications 50 attributes listed
Related part numbers 1 other part number in this family

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for SD2001?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the SD2001?

SD2001 is made by IFM and is listed in our Pneumatics category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SD2001, and the quote confirms condition and lead time before you order.

Is the SD2001 new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the SD2001, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of SD2001?

No published lifecycle status is on file for SD2001. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of SD2001?

Key specifications include Accuracy: ± 2; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN50); Ambient temperature: 32...140; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.

What voltage does SD2001 use?

Per the published specification for SD2001: Max. voltage drop switching output DC: 2; Operating voltage: 19...30 DC; (to SELV/PELV). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

What is the current rating of SD2001?

Per the published specification for SD2001: Permanent current rating of switching output DC: 250; (per output). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

What material is SD2001 made of?

Per the published specification for SD2001: Material: PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminum powder-coated. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How quickly can SD2001 ship?

Lead time for SD2001 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.