Beckhoff EL3356 — EtherCAT Terminals
Beckhoff EL3356 - EtherCAT Terminals - Weight: approx. 60 g; Operating Temperature: -25…+55°C; Storage Temperature: -40…+85°C.
Overview
The Beckhoff EL3356 is part of the EtherCAT Terminals range in our industrial catalog. The manufacturer's published data for this part number specifies Weight: approx. 60 g and Operating Temperature: -25…+55°C.
< ±0.01% for the calculated load value in relation to the final load value with a 12 V feed and 24 mV bridge voltage (hence nominal strain gauge characteristic value of 2 mV/V), self-calibration active, 50 Hz filter active Key manufacturer data on file for this item includes Storage Temperature: -40…+85°C; Relative Humidity: 95%, no condensation; Special Features: self-calibration, quadruple averager, dynamic filters; Power Supply: via the E-bus; Approvals/markings: CE, CCC, UL, ATEX, IECEx; Vibration/shock resistance: conforms to EN 60068-2-6/EN 60068-2-27; EMC immunity/emission: conforms to EN 61000-6-2/EN 61000-6-4; Ex marking: ATEX: II 3 G Ex ec IIC T4 Gc IECEx: Ex ec IIC T4 Gc; Protect. rating/installation pos.: IP20/variable; Current consumption E-bus: typ. 210 mA; Number of inputs: 2, for 1 resistor bridge in full bridge technology; Distributed clocks: –. The complete technical table is shown in the Specifications tab on this page.
Specifications
| Approvals/markings | CE, CCC, UL, ATEX, IECEx |
|---|---|
| Conversion rate | 100…4 samples/s (10…250 ms conversion time) |
| Current consumption E-bus | typ. 210 mA |
| Current consumption power contacts | dependent on strain gauge supply, min. 1 mA |
| Distributed clocks | – |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Ex marking | ATEX: II 3 G Ex ec IIC T4 Gc IECEx: Ex ec IIC T4 Gc |
| Input filter cut-off frequency | 10 kHz low pass (-3 dB) |
| Internal resistance | > 200 kΩ (UREF), > 1 MΩ (UD) |
| Measurement error/uncertainty | < ±0.01% for the calculated load value in relation to the final load value with a 12 V feed and 24 mV bridge voltage (hence nominal strain gauge characteristic value of 2 mV/V), self-calibration active, 50 Hz filter active |
| Measuring range UD | max. ±27 mV |
| Measuring range UREF | max. ±13.8 V |
| Number of inputs | 2, for 1 resistor bridge in full bridge technology |
| Operating Temperature | -25…+55°C |
| Pluggable wiring level | for all ESxxxx terminals |
| Power Supply | via the E-bus |
| Power supply UV | up to 12 V DC from power contacts, dependent on sensor |
| Protect. rating/installation pos. | IP20/variable |
| Relative Humidity | 95%, no condensation |
| Resolution | 16 bit, 32 bit presentation |
| Special Features | self-calibration, quadruple averager, dynamic filters |
| Storage Temperature | -40…+85°C |
| Supported nominal sensitivity | all, parameter resolution: 0.01 µV/V; recommended: 0.5…4 mV/V |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| Weight | approx. 60 g |
Product details
| Manufacturer | Beckhoff |
|---|---|
| Manufacturer part number | EL3356 |
| KKM catalog reference | BECKHOFF-EL3356 |
| Product category | Fieldbus Modules & Gateways |
| Published specifications | 25 attributes listed |
| Related part numbers | 13 other part numbers in this family |
Request a quote for this part
Email [email protected] or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for EL3356?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email [email protected], and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the EL3356?
EL3356 is a Beckhoff part. KKM Solutions sources Beckhoff components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
Is EL3356 discontinued, and can I still get one?
KKM Solutions does not publish a manufacturer lifecycle status for EL3356 — check Beckhoff's own product page for whether it is current, superseded, or end-of-life. It does not change what we can do: we source current-production, superseded and long-obsolete parts the same way, and where a part is genuinely unavailable we identify a form-fit-function equivalent. Send the part number through the quote form on this page, or use our obsolete part lookup at https://kkmsolutions.com/tools/obsolete-part-lookup/.
What are the key specifications of EL3356?
Key specifications include Approvals/markings: CE, CCC, UL, ATEX, IECEx; Conversion rate: 100…4 samples/s (10…250 ms conversion time); Current consumption E-bus: typ. 210 mA; Current consumption power contacts: dependent on strain gauge supply, min. 1 mA. The full specification table on this page lists every published attribute for this part.
How quickly can EL3356 ship?
In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Variants & Related Part Numbers
Other Beckhoff part numbers in this family:
- EL3311 — Beckhoff EL3311 Beckhoff
- EL3311-0000 — Beckhoff EL3311-0000 Beckhoff
- EL3312 — Beckhoff EtherCAT Terminal, 2-channel analog input, temperature, thermocouple, 16 bit EL3312
- EL3314 — Beckhoff EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 16 bit EL3314
- EL3314-0002 — Beckhoff EL3314-0002 Beckhoff
- EL3314-0010 — Beckhoff EL3314-0010 Beckhoff
- EL3314-0090 — Beckhoff EL3314-0090
- el33140010 — Beckhoff EL3314-0010 New In Box
- EL3318 — Beckhoff EtherCAT Terminal, 8-channel analog input, temperature, thermocouple, 16 bit EL3318
- EL3351 — Beckhoff EtherCAT Terminal, 1-channel analog input, measuring bridge, full bridge, 16 bit…
- EL3356-0010 — Beckhoff EL3356-0010
- EL3356-0020 — Beckhoff EL3356-0020 Beckhoff
- EL3356-FS — Beckhoff EL3356
Related Products
Beckhoff Beckhoff EtherCAT Terminal, 1-channel analog input, measuring bridge, full…
Beckhoff Beckhoff EtherCAT Terminal, 3-channel analog input, power measurement, 500…
Beckhoff Beckhoff EtherCAT Terminal, 8-channel analog input, temperature, thermocouple, 16…
Beckhoff Beckhoff EtherCAT Terminal, 3-channel analog input, power measurement, 480…
Beckhoff Beckhoff EtherCAT Terminal, 4-channel analog input, temperature, thermocouple, 16…
Beckhoff Beckhoff EtherCAT Terminal, 2-channel analog input, voltage, ±10 V,…
Browse more Beckhoff Industrial Networking, or see everything from Beckhoff.
Industrial Automation & MRO Parts