Skip to content
Stock is confirmed when you order, and we will advise you as soon as your order is confirmed. Need help with a part? Email orderdesk@kkmsolutions.com.
Ships worldwide — lead time quoted per part (825) 454-5367 Order desk 24/7 orderdesk@kkmsolutions.com
KKM Industrial and Automation Solutions Industrial Automation & MRO Parts Line down? Call the order desk (825) 454-536724/7
Call the order desk Get a quote
IFM Compressed air meter - SD1440

SD1440 IFM Compressed air meter

Brand: IFM SKU: SD1440 Mfr Part #: SD1440

KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.

Ships worldwide — lead time quoted per part

IFM SD1440 - Compressed air meter - Storage Temperature: -20...85; Ambient temperature: 0...60.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number SD1440 from IFM, listed in Pneumatics. Specifications on file: Ambient temperature 0...60; Analog current output 4...20; (scalable); Application for industrial applications; Communication interface IO-Link. KKM Solutions quotes this part with pricing and availability confirmed per order.

IFM SD1440 is a Compressed air meter catalog item from IFM. The manufacturer's published data for this part number specifies Storage Temperature: -20...85.

PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); stainless steel (1.4404 / 316L); FKM

The specification set recorded for this part number covers Ambient temperature: 0...60; Connector: 1 x M12; coding: A; Contacts: 4; Installation: Adjustable to inside pipe diameters; ( 14...254 mm); Protection class: III; Dimensions: 85.1 x 45.8 x 100.3; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: Compressed air meter; Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Response time: < 0.1; (dAP = 0, T09); Communication interface: IO-Link. See the Specifications tab on this page for the full technical table.

Specifications

Accuracy ± 0,5; (medium flow in the limit area of the flow measurement range)
Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); (reference conditions: diA = 73 mm; inlet pipe length >= 3 m; outlet pipe length >= 0,5 m; reference temperature: 20...25 °C; standard volume flow: 50...850 Nm³/h)
Ambient temperature 0...60
Analog current output 4...20; (scalable)
Application for industrial applications
Communication interface IO-Link
Connector 1 x M12; coding: A; Contacts: 4
Damping process value dAP 0...5
Dimensions 85.1 x 45.8 x 100.3
Dynamic response T05 / T09 T09 = 0,5
Electrical design PNP/NPN
Housing rectangular
Inputs counter reset
Installation Adjustable to inside pipe diameters; ( 14...254 mm)
IO-Link revision 1.1
Key Features Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting compressed air in industrial use; With switching output, analog output and pulse output; Adjustable to inside pipe diameters
Material PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); stainless steel (1.4404 / 316L); FKM
Materials (wetted parts) stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; ceramics glass passivated; PPS GF40; acrylate
MAWP (for applications according to CRN) 10
Max. load 500
Max. relative air humidity 90
Max. voltage drop switching output DC 2.5
Media compressed air; nitrogen (N2)
Medium temperature -10...60
Min. process cycle time 6.8
MTTF 190
Number of analog outputs 1
Number of digital outputs 2
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Operating voltage 18...30 DC; (to SELV/PELV)
Output function normally open / closed; (configurable)
Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable)
Overload protection yes
Pack quantity 1 pcs.
Parameter setting options hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer
Permanent current rating of switching output DC 150; (per output)
Power-on delay time 1
Process Connection threaded connection G 1 Internal thread
Process data analog 8
Process data binary 2
Product type Compressed air meter
Protection IP 65; IP 67
Protection class III
Pulse length 0.001...2
Pulse output consumed quantity meter
Repeatability ± 1,5 % MW
Required master port class A
Reverse polarity protection yes
SDCI standard IEC 61131-9 CDV
Short circuit protection yes
SIO mode yes
Specification Summary Compressed air meter; PNP/NPN; switching signal; analog signal; pulse signal; IO-Link; Measuring range 0.3...26260 m³/h; Medium temperature -10...60 °C; Pressure rating 50 bar; G 1 Internal thread; Connector
Storage Temperature -20...85
Temperature coefficient ± 0,07 % MW
Transmission type COM2 (38,4 kBaud)
Type of short-circuit protection yes (non-latching)

Product details

Manufacturer IFM
Manufacturer part number SD1440
Product category Pneumatics
Published specifications 56 attributes listed

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for SD1440?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the SD1440?

SD1440 is made by IFM and is listed in our Pneumatics category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SD1440, and the quote confirms condition and lead time before you order.

Is the SD1440 new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the SD1440, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of SD1440?

No published lifecycle status is on file for SD1440. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of SD1440?

Key specifications include Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): ± (6 % MW + 0,6 % MEW); (reference conditions: diA = 73 mm; inlet pipe length >= 3 m; outlet pipe length >= 0,5 m; reference temperature: 20...25 °C; standard volume flow: 50...850 Nm³/h); Ambient temperature: 0...60; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.

What voltage does SD1440 use?

Per the published specification for SD1440: Max. voltage drop switching output DC: 2.5; Operating voltage: 18...30 DC; (to SELV/PELV). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

What is the current rating of SD1440?

Per the published specification for SD1440: Permanent current rating of switching output DC: 150; (per output). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

What material is SD1440 made of?

Per the published specification for SD1440: Material: PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); stainless steel (1.4404 / 316L); FKM. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How quickly can SD1440 ship?

Lead time for SD1440 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Frequently Searched IFM Part Numbers

Related Products

More Pneumatics parts

Browse IFM part numbers starting with SD ›

Technical Guides

All Pneumatics & Air Systems articles ›

Browse more IFM Pneumatics, or see everything from IFM.