Compressed air meter - SD1440
IFM SD1440 - Compressed air meter - Weight: 372.6; Storage Temperature: -20...85; Ambient temperature: 0...60.
IFM SD1440 is a Compressed air meter catalog item from IFM. The manufacturer's published data for this part number specifies Weight: 372.6 and Storage Temperature: -20...85.
PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); stainless steel (1.4404 / 316L); FKM
The specification set recorded for this part number covers Ambient temperature: 0...60; Connector: 1 x M12; coding: A; Contacts: 4; Installation: Adjustable to inside pipe diameters; ( 14...254 mm); Protection class: III; Dimensions: 85.1 x 45.8 x 100.3; Number of digital outputs: 2; Application: for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: Compressed air meter; Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Response time: < 0.1; (dAP = 0, T09); Communication interface: IO-Link. See the Specifications tab on this page for the full technical table.
| Accuracy | ± 0,5; (medium flow in the limit area of the flow measurement range) |
|---|---|
| Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (reference conditions: diA = 73 mm; inlet pipe length >= 3 m; outlet pipe length >= 0,5 m; reference temperature: 20...25 °C; standard volume flow: 50...850 Nm³/h) |
| Ambient temperature | 0...60 |
| Analog current output | 4...20; (scalable) |
| Application | for industrial applications |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4 |
| Current consumption | < 80 |
| Damping process value dAP | 0...5 |
| Dimensions | 85.1 x 45.8 x 100.3 |
| Dynamic response T05 / T09 | T09 = 0,5 |
| Electrical design | PNP/NPN |
| Housing | rectangular |
| Inputs | counter reset |
| Installation | Adjustable to inside pipe diameters; ( 14...254 mm) |
| IO-Link revision | 1.1 |
| Key Features | Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; For detecting compressed air in industrial use; With switching output, analog output and pulse output; Adjustable to inside pipe diameters |
| Material | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); stainless steel (1.4404 / 316L); FKM |
| Materials (wetted parts) | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; ceramics glass passivated; PPS GF40; acrylate |
| MAWP (for applications according to CRN) | 10 |
| Max. load | 500 |
| Max. relative air humidity | 90 |
| Max. voltage drop switching output DC | 2.5 |
| Media | compressed air; nitrogen (N2) |
| Medium temperature | -10...60 |
| Min. process cycle time | 6.8 |
| MTTF | 190 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 18...30 DC; (to SELV/PELV) |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer |
| Permanent current rating of switching output DC | 150; (per output) |
| Power-on delay time | 1 |
| Process Connection | threaded connection G 1 Internal thread |
| Process data analog | 8 |
| Process data binary | 2 |
| Product type | Compressed air meter |
| Protection | IP 65; IP 67 |
| Protection class | III |
| Pulse length | 0.001...2 |
| Pulse output | consumed quantity meter |
| Repeatability | ± 1,5 % MW |
| Required master port class | A |
| Response time | < 0.1; (dAP = 0, T09) |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 CDV |
| Short circuit protection | yes |
| SIO mode | yes |
| Specification Summary | Compressed air meter; PNP/NPN; switching signal; analog signal; pulse signal; IO-Link; Measuring range 0.3...26260 m³/h; Medium temperature -10...60 °C; Pressure rating 50 bar; G 1 Internal thread; Connector |
| Storage Temperature | -20...85 |
| Temperature coefficient | ± 0,07 % MW |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | yes (non-latching) |
| Weight | 372.6 |
Frequently Asked Questions
How do I get pricing for SD1440?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SD1440?
SD1440 is a IFM part. KKM Solutions sources IFM components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of SD1440?
Key specifications include Accuracy: ± 0,5; (medium flow in the limit area of the flow measurement range); Accuracy (in the measuring range): ± (6 % MW + 0,6 % MEW); (reference conditions: diA = 73 mm; inlet pipe length >= 3 m; outlet pipe length >= 0,5 m; reference temperature: 20...25 °C; standard volume flow: 50...850 Nm³/h); Ambient temperature: 0...60; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
How quickly can SD1440 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
IFM Compressed air meter - SD0523
IFM Compressed air meter - SD1540
IFM Compressed air meter - SD2000
IFM Compressed air meter - SD2001
IFM Compressed air meter - SD2500
IFM