Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
IFM Conductive conductivity sensor - LDL321
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Conductive conductivity sensor - LDL321

Brand: IFM SKU: LDL321 Mfr Part #: LDL321
Ships Same Day* Worldwide Shipping

IFM LDL321 - Conductive conductivity sensor - Weight: 291.4; Storage Temperature: -25...75; Ambient temperature: -25...50.

This listing covers the IFM LDL321, a part number in the Conductive conductivity sensor category. The manufacturer's published data for this part number specifies Weight: 291.4 and Storage Temperature: -25...75.

housing: PP fiber-reinforced; process connection: PVDF; probe: stainless steel (1.4435 / 316L); insulator: PEEK; sealing: FKM

Published specifications for this part include Ambient temperature: -25...50; Connector: 1 x M12 (EN 61067-2-101); coding: A; Contacts: 4, gold-plated; Tightening torque: < 8; Protection class: III; Dimensions: Ø 32 / L = 166.5; Output signal: analog signal; IO-Link; Product type: Conductive conductivity sensor; Accuracy: -25...90 °C: < ± 0,5 K/ @ 25 °C: < ± 0,015 K; Response time: < 2; (T09; Damping = 0); conductivity <1 µS/cm: <5 s; (T09; Damping = 0); Communication interface: IO-Link; Measuring range: 0.04...1000; Operating voltage: 18...30 DC. The complete technical table is shown in the Specifications tab on this page.

Accuracy -25...90 °C: < ± 0,5 K/ @ 25 °C: < ± 0,015 K
Accuracy (in the measuring range) 3 % MW ± 0,00005 µS/cm
Ambient temperature -25...50
Analog current output 4...20
Cannot be used for See the operating instructions, chapter "Function and features".
Communication interface IO-Link
Connector 1 x M12 (EN 61067-2-101); coding: A; Contacts: 4, gold-plated
Current consumption < 60
Dimensions Ø 32 / L = 166.5
Drift 0,1 %/K; (referred to the ambient / electronics temperature)
Housing tubular
IO-Link revision 1.1
Key Features For effective, permanent control of water and process quality; Compact, high-quality sensor design prevents failures and unplanned downtime; Simplify your installation and commissioning processes
Long term stability 1,5 % MW ± 0,00002 µS/cm
Material housing: PP fiber-reinforced; process connection: PVDF; probe: stainless steel (1.4435 / 316L); insulator: PEEK; sealing: FKM
Materials (wetted parts) housing: PP fiber-reinforced; process connection: PVDF; probe: stainless steel (1.4435 / 316L); insulator: PEEK; sealing: FKM
Max. load 500
Measuring principle konduktiv
Measuring range 0.04...1000
Media Conductive liquids
Medium temperature -25...80
MTTF 181
Notes Digital meets analog: integrating modern IO-Link sensors the analog way. The EIO104 allows you to realize two analog signals from intelligent IO-Link sensors with several process values.
Number of analog outputs 1
Number of inputs and outputs Number of analog outputs: 1
Operating voltage 18...30 DC
Output function analog output scalable; selectable conductivity / specific resistance / temperature
Output signal analog signal; IO-Link
Pack quantity 1 pcs.
Power-on delay time 2
Process Connection threaded connection 1/2" NPT external thread
Product type Conductive conductivity sensor
Protection IP 68; IP 69; (7 days / 3 m water depth / 0.3 bar: IP 68; DIN EN 60529)
Protection class III
Repeatability 1 % MW ± 0,00002 µS/cm
Required master port class A
Resolution 0.1
Response time < 2; (T09; Damping = 0); conductivity <1 µS/cm: <5 s; (T09; Damping = 0)
Reverse polarity protection yes
SDCI standard IEC 61131-9
SIO mode no
Special Feature gold-plated contacts
Specification Summary Conductive conductivity sensor; Ø 32 / L = 166.5 mm; analog output scalable; selectable conductivity / specific resistance / temperature; analog; DC; M12 Connector; IP 68; IP 69; (7 days / 3 m water depth / 0.3 bar: IP 68; DIN EN 60529); Ambient temperature -25...50 °C; Pressure rating 16 bar; 1/2" NPT external thread; M12 Connector
Storage Temperature -25...75
Tightening torque < 8
Total number of outputs 1
Weight 291.4

Frequently Asked Questions

How do I get pricing for LDL321?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the LDL321?

LDL321 is a IFM part. KKM Solutions sources IFM components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of LDL321?

Key specifications include Accuracy: -25...90 °C: < ± 0,5 K/ @ 25 °C: < ± 0,015 K; Accuracy (in the measuring range): 3 % MW ± 0,00005 µS/cm; Ambient temperature: -25...50; Analog current output: 4...20. The full specification table on this page lists every published attribute for this part.

How quickly can LDL321 ship?

In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products