Overview
Part number 95IRS2-2 from Fireye, listed in Disconnect Switches. KKM Solutions quotes this part with pricing and availability confirmed per order.
Overview The Fireye 95IRS2-2 is a microprocessor-based, integrated infrared flame scanner designed for industrial burner management and flame safeguard applications. As part of the InSight I (95 Series) family, this “Enhanced” (S2) model is specifically designed for fiber-optic mounting, allowing for flame detection in environments where a direct line-of-sight is obstructed or where high temperatures require the electronics to be remote from the burner front. It combines both the sensor and amplifier into a single unit, providing a direct flame relay output and eliminating the need for remote rack-mounted amplifiers. Features Infrared (IR) sensing technology optimized for monitoring coal and oil-fired flames. Fiber-optic compatible design for flexible installation in complex burner geometries. Integrated flame and fault relays with adjustable ON/OFF thresholds. Electronic self-checking system that eliminates the need for a mechanical shutter. Eight-character alpha-numeric LED display and four-button keypad for local monitoring and configuration. Enhanced “S2” features including automatic programming (autotune), manual override, and 21 selectable modulation frequencies for superior flame discrimination. Rugged NEMA 4X / IP66 housing suitable for hazardous locations (Class I, Div 2). Specifications Model Number: 95IRS2-2 Input Power: 24 Vdc (+10%, -15%), 0.35A Output Relays: Flame (SPST N.O.) and Fault (SPST N.C.) Analog Output: 4-20mA dc current for signal strength monitoring. Electrical Connection: 12-pin quarter-turn quick-disconnect. Temperature Rating: -40 degrees F to +150 degrees F (-40 degrees C to +65 degrees C). Humidity: 0% to 95% relative humidity, non-condensing. Cooling/Purge Air: Requires clean, dry air (typically 4-15 SCFM depending on application). Approvals: FM and CSA approved. Applications The 95IRS2-2 is primarily used in industrial and utility power plant applications for monitoring burners fired with coal or heavy oil. Its fiber-optic capability makes it ideal for tilting tangential-fired boilers, package boilers with obstructed sight paths, and installations where the scanner must be protected from high ambient temperatures near the burner windbox. It is commonly applied in multi-burner environments where precise discrimination between the target flame and background radiation is required.
Product details
| Manufacturer | Fireye |
|---|---|
| Manufacturer part number | 95IRS2-2 |
| Product category | Disconnect Switches |
| Related part numbers | 6 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for 95IRS2-2?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 95IRS2-2?
95IRS2-2 is made by Fireye and is listed in our Disconnect Switches category. KKM Solutions is an independent distributor, not an authorized Fireye dealer: we source the exact Fireye part number 95IRS2-2, and the quote confirms condition and lead time before you order.
Is the 95IRS2-2 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the 95IRS2-2, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of 95IRS2-2?
No published lifecycle status is on file for 95IRS2-2. Fireye lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
How quickly can 95IRS2-2 ship?
Lead time for 95IRS2-2 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other Fireye part numbers in this family:
Related Products
Fireye 95UVS2-1 Fireye Scanner
Fireye 95IRS2-1 Fireye Scanner
Fireye 95UVS2-1CEX Fireye Scanner
Photo on request
85UVF1-1CEX Fireye Cenelec Explosion Proof Housing
Photo on request
C9504M-001 Fireye Scanner
Photo on request
C9507N4012 Fireye Scanner
Browse more Fireye Circuit Protection, or see everything from Fireye.