CA71MN Endress+Hauser Stamolys
KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.
Endress+Hauser CA71MN - Liquid analysis - Size: 648 x 436 x 250 mm 25.27 x 17.00 x 9.75inch; Ambient temperature: 5°C ... 40°C 41 ... 104°F; Application: Water / Wastewater / Processwater.
Overview
Part number CA71MN from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Ambient temperature 5°C ... 40°C 41 ... 104°F; Application Water / Wastewater / Processwater; Characteristic Analyser for manganese; Consumables Chemicals necessary. KKM Solutions quotes this part with pricing and availability confirmed per order.
In our catalog, the CA71MN from Endress+Hauser is listed under the Liquid analysis category. The manufacturer's published data for this part number specifies Size: 648 x 436 x 250 mm 25.27 x 17.00 x 9.75inch and Ambient temperature: 5°C ... 40°C 41 ... 104°F.
at any time adaptable at suburb/customer conditions, two-channelversion available, sample fertilization without further pump possible
Published specifications for this part include Application: Water / Wastewater / Processwater; Power Supply: 115 V AC / 230 V AC, 50/60 Hz; Measuring range: 1 ... 150 µg/l Mn 10 ... 2000 µg/l Mn; Design: GRP, Stainless steel or open frame; Process pressure: pressureless < 0,2 bar 3psi; Output / communication: 0/4 ... 20 mA Contacts: 2 limit contacts (per channel), 1 system alarm contact; Characteristic: Analyser for manganese; Process temperature: 10°C ... 30°C 50 ... 86°F; Sample flow rate: min. 5 ml/min; Consistency of the sample: low solid content(TS<50mg/l); Consumables: Chemicals necessary. See the Specifications tab on this page for the full technical table.
Specifications
| Ambient temperature | 5°C ... 40°C 41 ... 104°F |
|---|---|
| Application | Water / Wastewater / Processwater |
| Characteristic | Analyser for manganese |
| Consumables | Chemicals necessary |
| Design | GRP, Stainless steel or open frame |
| Measuring range | 1 ... 150 µg/l Mn 10 ... 2000 µg/l Mn |
| Output / communication | 0/4 ... 20 mA Contacts: 2 limit contacts (per channel), 1 system alarm contact |
| Power Supply | 115 V AC / 230 V AC, 50/60 Hz |
| Process temperature | 10°C ... 30°C 50 ... 86°F |
| Sample flow rate | min. 5 ml/min |
| Size | 648 x 436 x 250 mm 25.27 x 17.00 x 9.75inch |
| Specials | at any time adaptable at suburb/customer conditions, two-channelversion available, sample fertilization without further pump possible |
Product details
| Manufacturer | Endress+Hauser |
|---|---|
| Manufacturer part number | CA71MN |
| Product category | Vision, Measurement & Identification |
| Published specifications | 12 attributes listed |
| Related part numbers | 12 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for CA71MN?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the CA71MN?
CA71MN is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CA71MN, and the quote confirms condition and lead time before you order.
Is the CA71MN new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the CA71MN, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of CA71MN?
No published lifecycle status is on file for CA71MN. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of CA71MN?
Key specifications include Ambient temperature: 5°C ... 40°C 41 ... 104°F; Application: Water / Wastewater / Processwater; Characteristic: Analyser for manganese; Consumables: Chemicals necessary. The full specification table on this page lists every published attribute for this part.
How quickly can CA71MN ship?
Lead time for CA71MN is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other Endress+Hauser part numbers in this family:
Frequently Searched Endress+Hauser Part Numbers
Related Products
Endress+Hauser Endress+Hauser Stamolys CA71HY
Endress+Hauser Endress+Hauser Stamolys CA71NO
Endress+Hauser Endress+Hauser Stamolys CA71HA
Endress+Hauser Endress+Hauser Stamolys CA71PH
Endress+Hauser Endress+Hauser Stamolys CA71FE
Endress+Hauser Endress+Hauser Stamolys CA71SI
More Vision, Measurement & Identification parts
Technical Guides
Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.
Industrial Automation & MRO Parts