Allen-Bradley NEMA Size 0 Contactor 300-AOEQ9310

300-AOEQ9310 Allen-Bradley NEMA Size 0 Contactor

Brand: Allen-Bradley SKU: 300-AOEQ9310

KKM Solutions is an independent parts distributor, not an authorized Allen-Bradley dealer — how we source.

Ships worldwide — lead time quoted per part

Allen-Bradley 300-AOEQ9310 - Contactors - Function: Energy-saving contactor; Weight: AC/DC (electronic): 0.43 kg (0.95 lbs.); Ambient temperature: Storage range: -55...80 °C (-67...176 °F).

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number 300-AOEQ9310 from Allen-Bradley, listed in NEMA Contactors & Starters. Specifications on file: Altitude, max 2000 m of installation site; Coil Electronic; Coil operating limits, dropout 30...60% x voltage @ 50/60 Hz; Coil operating limits, pick-up 85...10% x voltage @ 50/60 Hz. KKM Solutions quotes this part with pricing and availability confirmed per order.

Allen-Bradley 300-AOEQ9310 is a Contactors catalog item from Allen-Bradley. The manufacturer's published data for this part number specifies Function: Energy-saving contactor and Weight: AC/DC (electronic): 0.43 kg (0.95 lbs.).

Sizes 0...3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1...3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4...8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.)

Published specifications for this part include Ambient temperature: Storage range: -55...80 °C (-67...176 °F); Lifecycle Status: Active; Type of electrical connection of main circuit: Screw connection; Voltage type for actuating: DC; Switching frequency, max: 600 ops/hr, AC-1; Number of auxiliary contacts as normally open contact: 1; Number of auxiliary contacts as normally closed contact: 0; Rated control supply voltage at DC: 12 V; Rated isolation voltage (Ui): 690V per IEC; Protection class: Contactor main contact: IP2X; Rated voltage (Ue): 24V @ 48V, 110V @ 220V, 440V DC; Humidity: Non-condensing: 5...95%. See the Specifications tab on this page for the full technical table.

Specifications

Altitude, max 2000 m of installation site
Ambient temperature Storage range: -55...80 °C (-67...176 °F)
Available short circuit ampere 65,000A @ 480V max, circuit breaker, RMS symmetrical
Climatic withstand Category B according to IEC 60947-1, annex Q
Coil Electronic
Coil operating limits, dropout 30...60% x voltage @ 50/60 Hz
Coil operating limits, pick-up 85...10% x voltage @ 50/60 Hz
Contacts Sizes 0...3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1...3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4...8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.)
Continuous ampere rating 3-poles: 18 A
DIN fuses (gG) current rating Type 2 (per IEC 60947-4-1): 32A @ 400V, 100 kA available fault current
Electromagnetic compatibility IEC 60947-1 - Environment A and B
Energy-efficient coil, hold-in 1.7 W @ 12-20V DC
Energy-efficient coil, pick-up 12...16 W @ 12-20V DC
Features Compact size, Sizes 00...5: AC/DC electronic coil with optional PLC interface, Sizes 6...8: AC/DC with PLC interface, Integrated surge suppression, Panel or DIN Rail mountable, Finger safe, Complete range of accessories, Meets global standards, Consists o
FLA 25A @ 600V, 3-phase per UL/CSA HVAC applications
Function Energy-saving contactor
Fuse type H, J, R
General purpose current (enclosed) 16A @ 600V per UL/CSA
Heat dissipation 4.7 W
Horsepower rating, max 3-poles: 5Hp @ 575V, three-phase, full-load current must not exceed continuous Aere rating (60 Hz)
Humidity Non-condensing: 5...95%
Lifecycle Status Active
LRA 150 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
Main current circuit resistance 0.46 mΩ
MCCB current rating Type 2 (per IEC 60947-4-1): 28A @ 400V, 70 kA available fault current
Mechanical life 13 mons of ops
NEMA size 00...8
Number of auxiliary contacts as normally closed contact 0.000000
Number of auxiliary contacts as normally open contact 1
Number of auxiliary contacts, max 8
Operating limits, dropout (≤0.60) x Us @ DC control
Operating limits, pick-up (0.80...1.1) x Us @ DC control
Operating position Vertical
Operating time, closing delay 15 ms
Operating time, drop-out 10 ms
Operating time, opening delay 10 ms
Operating time, pick-up 15 ms
Operating volt amperes 8VA @ 50/60 Hz, sealed
Optional accessories Side- or front-mount auxiliary contacts, Mechanical interlocks, Terminal lugs, Terminal shields, Connecting bars
Power dissipation 1 W per pole at Ie, AC-1, 400V
Protection class Contactor main contact: IP2X
Rated control supply voltage at DC 12 V
Rated impulse voltage withstand (Uimp) 6 kV
Rated isolation voltage (Ui) 690V per IEC
Rated operational current (Ie) 9A @ 690V, Star-Delta starting (50 Hz)
Rated operational current and power 7.60A @ 460V AC, 500000 electrical ops, 3-phase per UL/CSA elevator duty
Rated operational current and power (enclosed) 9.6 A @ 220-240V, 3-phase per UL/CSA
Rated operational power (Pe) 7.5 kW @ 690V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F)
Rated voltage (Ue) 24V @ 48V, 110V @ 220V, 440V DC
Required torque Load: 22 lbin
Shock resistance IEC 60068-2-27
Short time withstand (Icw) 3-pole: 80A @ 30s (40 °C)
Switching frequency, max 600 ops/hr, AC-1
Switching of DC loads 3-poles in series: 27A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C)
Switching of lighting loads Tungsten lA: 25A @ 600V, 3-phase (break all lines) per UL/CSA
Switching of power transformers Apparent power: 9 kVA @ 400V, AC-6a @ 50Hz (n = 30)
Total power dissipation 2.6 W at Ie, AC-3, 400V, AC/DC control (120-250V)
Type of electrical connection of main circuit Screw connection
UL class J and CSA HRCI-J fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 30A @ 600V, 100 kA available fault current
UL class RK5 fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 30A @ 600V, 5 kA available fault current
UL inverse-time circuit breaker Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60A @ 600V, 5 kA available fault current
Vibration resistance IEC 60068-2-6
Voltage type for actuating DC
Weight AC/DC (electronic): 0.43 kg (0.95 lbs.)
Wire size Load: 16...10 AWG for power terminals

Product details

Manufacturer Allen-Bradley
Manufacturer part number 300-AOEQ9310
Product category NEMA Contactors & Starters
Manufacturer lifecycle status Active
Published specifications 65 attributes listed

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for 300-AOEQ9310?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 300-AOEQ9310?

300-AOEQ9310 is an Allen-Bradley part, sourced to the exact manufacturer specification.

What is the lifecycle status of 300-AOEQ9310?

Manufacturer lifecycle status on file for 300-AOEQ9310: "Active" — not recorded as discontinued. That is the value published in the product data we hold; confirm against Allen-Bradley's own product page before a long-lead order, as feed data can lag an announcement. It does not change what we can do: KKM Solutions sources current-production, superseded and long-obsolete parts the same way. Send 300-AOEQ9310 through the quote form on this page for pricing and availability.

What are the key specifications of 300-AOEQ9310?

Key specifications include Altitude, max: 2000 m of installation site; Ambient temperature: Storage range: -55...80 °C (-67...176 °F); Available short circuit ampere: 65,000A @ 480V max, circuit breaker, RMS symmetrical; Climatic withstand: Category B according to IEC 60947-1, annex Q. The full specification table on this page lists every published attribute for this part.

How quickly can 300-AOEQ9310 ship?

Lead time is quoted per part and confirmed on your quote.

Related Products

Browse more Allen-Bradley Contactors & Motor Starters, or see everything from Allen-Bradley.

Looking for a discontinued or hard-to-find Allen-Bradley part? Read our Allen-Bradley Lifecycle Status guide, or use the obsolete part lookup.