Allen-Bradley 150-C37NBD - Compact AC Motor Soft Starters - Width: 44.8 mm (1.76 in) mm; Height: 139.7 mm (5.5 in) mm; Enclosure: Open type.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Allen-Bradley 150-C37NBD is a Compact AC Motor Soft Starters catalog item from Allen-Bradley. The manufacturer's published data for this part number specifies Width: 44.8 mm (1.76 in) mm and Height: 139.7 mm (5.5 in) mm.

2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm² (4 AWG) wire in top terminal for line power terminal

The specification set recorded for this part number covers Enclosure: Open type; Function: Single direction; Weight: 0.86 kg; Operating Temperature: Open: -5 to 50 °C (23 to 122 °F); Sub Brand: SMC-3; Degree of protection (IP): IP2X; Depth: 110 mm (4.33 in); Rated control supply voltage at AC 50 Hz: 100 V; Rated control supply voltage at AC 60 Hz: 100 V; Voltage type for actuating: AC/DC; Altitude: 2000 m; Number of poles: Equipment is designed for 3-phase only for power circuit. See the Specifications tab on this page for the full technical table.

Altitude 2000 m
Break TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Cable size 2.5...25 mm² (14...4 AWG) for line power terminals
Controller type SMC-3
Conventional thermal current (Ith) TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Degree of protection (IP) IP2X
Delta connected motor current 21…64A @ 380/400/415/460V AC, 3-phase
Delta connected motor power, max 7.5...30 kW @ 380/400/415V AC @ 50Hz, 3-phase
Depth 110 mm (4.33 in)
Dielectric withstand 2500V AC per IEC for power circuit
DV/DT protection 1000V/µs for power circuit
EMC emission levels Radiated emission: Class A per IEC
EMC immunity levels Surge transient: per EN/IEC 60947-4-2 per IEC
Enclosure Open type
Estimated Lead Time 5 days
Function Single direction
Height 139.7 mm (5.5 in) mm
High capacity available fault current, max 70kA @ 600V, maximum current 60 A time delay Class J or Class L fuse for line connected motors
Humidity 5...95% noncondensing
Input OFF-state current <10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Input OFF-state voltage (IN1, IN2), max 40V AC @ 17V DC/12V AC for control circuit
Input ON-state current (IN1, IN2) 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Input ON-state voltage, during start (IN1, IN2) 85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit
Integrated motor overload protection True
Internal bypass True
Line connected motor current 12.3...37A @ 380/400/415/460V AC, 3-phase
Line connected motor power, max 7.5 kW @ 230V AC @ 50Hz, 3-phase
Make TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Mounting hole size 4.6 mm
Number of contacts TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
Number of poles Equipment is designed for 3-phase only for power circuit
Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit
Operating Temperature Open: -5 to 50 °C (23 to 122 °F)
Overload Current 12.3 A
Overvoltage category III per IEC for side mount auxiliary contacts
Pollution degree 2
Rated control power during start with fan 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Rated control power during start without fan 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Rated impulse voltage 6 kV for power circuit
Rated operating voltage Ue 200 V
Rated operational current, max TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Rated surrounding temperature range without derating -5 °C
Repetitive peak voltage 1400V per UL/CSA/NEMA for power circuit
Selectable current limit 150%, 250%, 350%, and 450% of full load current
Selectable initial torque 15%, 25%, 35%, and 65% of locked rotor torque
Selectable kick start - 450% FLA 0, 0.5, 1.0, or 1.5 s
Selectable overload trip class Trip Class 10, 15, or 20
Selectable soft stop Off, 100%, 200%, or 300% of the start time setting when wired
Selectable start times 2, 5, 10, 15, 20, 25, or 30 s
Shock Opsal: 15 G
Short circuit protection device performance (SCPD) type Type 1
Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Standard available fault current, max 10 kA @ maximum standard fuse 250 A for delta device opsal current rating
Standard controller feature Soft stop
Standard Warranty Duration 1 year
Steady state heat dissipation 24 W
Storage and transportation temperature -25 °C
Sub Brand SMC-3
Tightening torque 2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm² (4 AWG) wire in top terminal for line power terminal
Type of contacts TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Type of control circuit TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Type of current TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
UPC 611320640816
Utilization category TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Vibration Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Voltage type for actuating AC/DC
Weight 0.86 kg
Width 44.8 mm (1.76 in) mm
With display False

Request a quote for this part

Email [email protected] or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How much does 150-C37NBD cost?

150-C37NBD is available for direct purchase at CA$988.06 (CAD), shown on this page with an Add to Cart button. Larger quantities or custom terms — email [email protected] for a volume quote.

Who manufactures the 150-C37NBD?

150-C37NBD is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

Is 150-C37NBD discontinued, and can I still get one?

KKM Solutions does not publish a manufacturer lifecycle status for 150-C37NBD — check Allen-Bradley's own product page for whether it is current, superseded, or end-of-life. It does not change what we can do: we source current-production, superseded and long-obsolete parts the same way, and where a part is genuinely unavailable we identify a form-fit-function equivalent. Send the part number through the quote form on this page, or use our obsolete part lookup at https://kkmsolutions.com/tools/obsolete-part-lookup/.

What are the key specifications of 150-C37NBD?

Key specifications include Altitude: 2000 m; Break: TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts; Cable size: 2.5...25 mm² (14...4 AWG) for line power terminals; Controller type: SMC-3. The full specification table on this page lists every published attribute for this part.

How quickly can 150-C37NBD ship?

In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Variants & Related Part Numbers

Other Allen-Bradley part numbers in this family:

  • 150-C30NBDAllen-Bradley 150-C30NBD SMC-3 30A Smart Motor Controller New
  • 150-C30NBD-NCAllen-Bradley 150-C30NBD-NC
  • 150-C30NBRAllen-Bradley 150-C30NBR SMC-3 30A Smart Motor Controller New
  • 150-C361NBRAllen-Bradley 150-C361NBR
  • 150-C361NCDSmart Motor Controller,361A,600V, 3 Phase, 50/60Hz,100...240V AC,Open
  • 150-C37FBDSmart Motor Controller,37 A,480V AC 50/60 Hz Three Phase,120V AC,IP65/NEMA 4 Enclosure
  • 150-C37NBRAllen-Bradley 150-C37NBR SMC-3 37A Smart Motor Controller New
  • 150-C3FBDSmart Motor Controller,0.125,480V AC 50/60 Hz Three Phase,120V AC,IP65/NEMA 4 Enclosure
  • 150-C3NBDAllen-Bradley SMC-3 3A Smart Motor Controller 150-C3NBD
  • 150-C3NBRAllen-Bradley SMC-3 3A Smart Motor Controller 150-C3NBR
  • 150-C3NCDAllen-Bradley SMC-3 3A Smart Motor Controller 150-C3NCD
  • 150-C3NCRAllen-Bradley SMC-3 3A Smart Motor Controller 150-C3NCR

Related Products