Allen-Bradley 1440-SDM02-01RA
CA$3,690.79 Card authorized at checkout — charged only once our order desk confirms the part and price.
Request a Quote Email [email protected] or call (825) 454-5367 for pricing and availability.
Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Allen-Bradley 1440-SDM02-01RA

Brand: Allen-Bradley SKU: 1440-SDM02-01RA Mfr Part #: 1440-SDM02-01RA
Ships Same Day* Worldwide Shipping

Allen-Bradley 1440-SDM02-01RA - Drives & Motors category.

In our catalog, the 1440-SDM02-01RA from Allen-Bradley is listed under the Drives & Motors category.

Specification data for this part number is available on request from our order desk.

4...20 mA outputs Each output is independently progmed to represent any measured param, from either channel, Two isolated outputs, 300 Ω max load
Accuracy, min ±1% of full scale range for the channel, ±1% of alarm setpoint for speed
Activation on Alarm Status: Normal, Alert, Danger, Disarm, Transducer fault, Module fault, Tacho fault
Alarm parameters Any measured param
Band pass digital filter Independently configured per channel, Frequency, min 25...1000 Hz, Frequency, max 100…5500 Hz, Roll off: -60 dB/octave
Buffered outputs One active buffer per dynamic channel, One resistive buffer for tachom
Complex data Spectra (synchronous or asynchronous), Waveform (synchronous or asynchronous), Simultaneous waveforms (synchronous), gSE Spectra
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Delta rpm buffer Number of records: 512, Delta speed interval: 1…3600 rpm, Trigger mode: Startup collects data in increasing rpm direction only, coast-down collects data in both increasing and decreasing directions, The data that is collected in the buffer is user configu
Delta time buffer Number of records: 2048, Delta time interval: 1…3600 s, Trigger mode: Relay is activated or trigger event (such as DeviceNet command from a controller or host)
Depth 94 mm
DeviceNet network Standard DeviceNet protocol for all functions (not power-module power is provided independently), Available EDS file supports most DeviceNet compliant systems, Communication rate that is set automatically by bus master to 125 Kbps, 250 Kbps, or 500 Kbps,
EFT/B immunity ±3kV @ 5kHz on power ports, ±3kV @ 5kH on signal ports, ±3kV @ 5kHz on DeviceNet ports
Emissions Class A
Enclosure type rating None (open-style)
ESD immunity 6 kV contact discharges, 8 kV air discharges
Estimated Lead Time 5 days
Ethernet False
Expected life (min operations) Mechanical: 2x10^7, Electrical @ 20 cpm, 1.5A @ 24V DC: 10^5
Failsafe Normally energized (fail-safe), Normally de-energized (non-failsafe)
FFT derived FFT bands, Four bands per channel, Defined in frequency or order domain, Overall or max peak in band, Orders, Magnitude: 1x, 2x, 3x, Phase: 1x, 2x, Not 1x, Sum harmonics
FFT lines 100, 200, 400, 800, 1600
Height 97 mm mm
High pass analog filters -3 dB corners: 0.2, 1, 5, 10, 40 Hz, Roll off: -30 dB/octave for the 0.2 Hz filter, otherwise 24 dB/octave
Hysteresis User configurable in software
Input impedance >120 kΩ
Integration None, single or double
Isolation voltage 50V (continuous), basic insulation type between uninsulated live parts and the enclosure with the relay contacts open and closed, Type tested at 707V DC @ 60s between uninsulated live parts and the enclosure with the relay contacts open and closed, Typ
Latching Latching, non-latching
Logic Single or paired AND or OR logic that is applied to any alarm
Low pass analog filter Applied to integrated acceleration measurements, -3 dB corner: 5 kHz, roll off: -18 dB/octave
Low pass digital filter Independently configured per channel, Optional Overall LP Filter, 100...20000 Hz, Spike Energy, Spectra FMAX: 10...5000 Hz, Roll Off: -24 dB/octave
Model Basic device
Modular expandable True
Nonvolatile configuration A copy of the module configuration is retained in nonvolatile memory from which the configuration is loaded upon powerup, The configuration that is stored in nonvolatile memory can be deleted only by a module-reset,command that is sent via a serial interf
Number Sixteen alarm and danger pairs
Number of indicator outputs 7
Number of rotational speed inputs 1
Number of sensor inputs for IEPE sensors 2
One tachometer input ±25V (50V max peak-to-peak), 1...50,000 events/revolution
Operating Temperature -20 °C
Operators Greater than, Less than, Inside range, Outside range
Output 2
Peak speed capture The XM-124 retains the value of the highest speed that is observed since module power was cycled or the peak speed value was manually reset
Power Supply 24V DC @ 350mA, Requires Class 2/SELV/PELV power supply
Pulses per revolution 0 (tach off)…50,000
Radiated RF immunity 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Range 1...1,200,000 rpm, 0.0167…20,000 Hz
Rate of change of speed, max 500 Hz/s
Rating (resistive) Capacity, nominal: 1.5A @ 24V DC, Capacity, min 100 µA @ 100 mV DC, Power, max 41.4 W, Voltage, max 27.6V DC, Current, max 1.5 A
Real time Overall, RMS, Peak (true or calculated), Peak-to-peak (true or calculated), gSE, Optional low pass filter, -3 dB corner: 200 Hz...20 kHz, Roll off: -24 dB/octave, Gap (or transducer bias voltage), Speed, SMAX magnitude, SMAX phase, Band pass filter value,
Relative Humidity 5...95% noncondensing
Reset Local reset switch on top of module, Remote reset switch that is wired to terminal base, Digital reset command via serial or DeviceNet interface
Resolution A/D conversion: 24 bit, Dynamic range: 80 dbfs (0.01% fs), 90 dbfs, typical
Sampling mode Selectable per channel, Dynamic Measurements, Asynchronous, FMAX: 1 Hz…20 kHz, Synchronous, Order range: 4…200, FMAX: 10 Hz…5000 Hz, Measured: orders x speed (Hz), Spike Energy, Static Measurements, Eccentricity, Peak-to-Peak Eccentricity, Thrust, Normal
Sensitivity Up to 15% from nom
Serial RS-232 via mini-connector or terminal base unit, Communication rate that is fixed at 19.2 Kbps, Local configuration via the Serial Configuration Utility
Shock Opsal: 15 G
Spectra or waveform Saved upon same trigger as delta time buffer
Speed inhibit A speed range can be specified for each alarm. When applied, the alarm is disabled when speed is outside of the defined range.
Standard Warranty Duration 1 year
Startup inhibit/setpoint multiplication Period: 0...1092 min, adjustable in 0.1 min increments, Inhibit/multiplication function, Multiply by N (0...10, 0 = Disarm)
Status indicator Module, Network, Channel 1, Channel 2, Tachom, Setpoint multiplier, Virtual relay
Storage Temperature -40 °C
Suitable for bus connection True
Surge transient immunity ±1 kV line-line (DM) and ±2 kV line-earth (CM) on power and relay ports, ±2 kV line-earth (CM) on shielded signal ports, ±2 kV line-earth (CM) on DeviceNet ports
Surrounding air temperature, max 65 °C
Time delay 0…25.5 s, adjustable in 100 ms increments
Tracking digital filter Independently configured per channel, Tracked speed multiple: 0.1...20.0 times the measured (tachom) rpm, Constant Q: 1...200, Constant bandwidth: 0.1...25 Hz, Roll off: -36 dB/octave, Typical
Transducer Power IEPE Accel, ECP's, Volts
Two dynamic channel inputs Eddy current transducer signals, Accelerom signals, Voltage signals from any dynamic measurement sensor, such as velocity or pressure transducer
Type FFT and time waveform, Asynchronous or synchronous
Type of electric connection Screw connection
Type of fastening Direct mounting
Units G, ips, mm/s, mils, µm, PSI, mbar, volt
UPC 884951743045
Vibration 5 G @ 10...500 Hz
Voltage ranges -20…0V DC, -10...10V DC, 0…20V DC
Voltage type of supply voltage DC
Weight Module: 0.172 kg (0.38 lb), Terminal base: 0.172 kg (0.38 lb)
Width 94 mm mm
Wiring category 2 - on signal ports, 1 - on power and relay ports, 2 - on DeviceNet ports, 3 - on serial ports

Frequently Asked Questions

How much does 1440-SDM02-01RA cost?

1440-SDM02-01RA is available for direct purchase at CA$3,690.79 (CAD), shown on this page with a Buy Now button. Prices can be displayed in USD, EUR or GBP for convenience, but orders are invoiced and charged in Canadian dollars. Larger quantities or custom terms — email [email protected] for a volume quote.

Who manufactures the 1440-SDM02-01RA?

1440-SDM02-01RA is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 1440-SDM02-01RA?

Key specifications include 4...20 mA outputs: Each output is independently progmed to represent any measured param, from either channel, Two isolated outputs, 300 Ω max load; Accuracy, min: ±1% of full scale range for the channel, ±1% of alarm setpoint for speed; Activation on: Alarm Status: Normal, Alert, Danger, Disarm, Transducer fault, Module fault, Tacho fault; Alarm parameters: Any measured param. The full specification table on this page lists every published attribute for this part.

How quickly can 1440-SDM02-01RA ship?

In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.