Skip to content
Stock is confirmed when you order, and we will advise you as soon as your order is confirmed. Need help with a part? Email orderdesk@kkmsolutions.com.
Ships worldwide — lead time quoted per part (825) 454-5367 Order desk 24/7 orderdesk@kkmsolutions.com
KKM Industrial and Automation Solutions Industrial Automation & MRO Parts Line down? Call the order desk (825) 454-536724/7
Call the order desk Get a quote
SHINWA RULES 73014

73014 SHINWA RULES Handheld Digital Thermometer - Infrared with Laser Pointer

Brand: SHINWA RULES SKU: 73014 Mfr Part #: 73014

KKM Solutions is an independent parts distributor, not an authorized SHINWA RULES dealer — how we source.

Ships worldwide — lead time quoted per part
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number 73014 from SHINWA RULES. Specifications on file: + output Within 1 mW (JIS class 2); 1 Scale 1; Battery life Continuous usable time is about 14 hours; Laser wavelength 635~660. KKM Solutions quotes this part with pricing and availability confirmed per order.

SHINWA RULES 73014. Specs: Type: Variable emissivity type · + output: Within 1 mW (JIS class 2) · Power Supply: AAA Alkaline Batteries x 2 (Included for Testing) · Temperature Measurement Range: -60 to 625 · Operating temperature range: 0 to 50 · Battery life: Continuous usable time is about 14 hours · Laser wavelength: 635~660 · Mass: 245. Quoted per order by KKM Solutions.

Specifications

+ output Within 1 mW (JIS class 2)
1 Scale 1
Auto Power-Off After 60 seconds in the non-operational state
Battery life Continuous usable time is about 14 hours
Laser wavelength 635~660
Main Body Size 185×46×143
Mass 245
Measurement Precision 0 to 625°C: ±2% or ±2°C (use the higher value) / -60 to 0°C: ±2°C + Display Temperature x 0.05°C
Minimum Temperature Display -9.9 to 199.9: 0.1/Otherwise: 1
Operating temperature range 0 to 50
Power Supply AAA Alkaline Batteries x 2 (Included for Testing)
Product Model Radiation Thermometer
Radiation Rate Adjustable from 0.1 to 1 (initial setting is 0.95)
Temperature Measurement Range -60 to 625
Type Variable emissivity type

Product details

Manufacturer SHINWA RULES
Manufacturer part number 73014
Published specifications 15 attributes listed
Related part numbers 1 other part number in this family

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for 73014?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 73014?

73014 is made by SHINWA RULES. KKM Solutions is an independent distributor, not an authorized SHINWA RULES dealer: we source the exact SHINWA RULES part number 73014, and the quote confirms condition and lead time before you order.

Is the 73014 new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is surplus, new-old-stock, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the 73014, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of 73014?

No published lifecycle status is on file for 73014. SHINWA RULES lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of 73014?

Key specifications include + output: Within 1 mW (JIS class 2); 1 Scale: 1; Auto Power-Off: After 60 seconds in the non-operational state; Battery life: Continuous usable time is about 14 hours. The full specification table on this page lists every published attribute for this part.

What operating temperature is 73014 rated for?

Per the published specification for 73014: Operating temperature range: 0 to 50. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How quickly can 73014 ship?

Lead time for 73014 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Variants & Related Part Numbers

Other SHINWA RULES part numbers in this family:

Related Products