Reliance Electric 125R4160 GV3000/SE AC Drive, Vector 100-125 HP, 380-460 V, NEMA 1
Reliance GV3000/SE vector AC drive, 100-125 HP, 380-460 V, NEMA 1, 159 A input. Please email [email protected] to check stock for this item -- send the part number and the quantity you need and the order desk will come back with current availability, lead time and pricing, usually the same business day.
Overview
Reliance Electric 125R4160 is a GV3000/SE AC drive rated by Rockwell for Vector regulation at 100-125 HP, 380-460 V, in a NEMA 1 enclosure with Version 6.0 regulator firmware. Table 2.1 of the GV3000/SE Hardware Reference gives 127 kVA and 159 A input, and output current that derates with carrier frequency: 152 A at 2 kHz, 122 A at 4 kHz and 91.0 A at 8 kHz, with 2410 W full-load power loss. Size the installation for the carrier you will actually run, not the headline figure. The R in the model number is the vector-regulation rating. Rockwell rates the same hardware differently under V/Hz regulation, which is why you will see this drive quoted at a higher horsepower elsewhere -- ask us which regulation mode your application needs. GV3000/SE model numbers read [horsepower][regulation][voltage][enclosure][regulator version]: the letter is the regulation type (T, V and R are V/Hz or Vector, G is V/Hz only), then voltage (2 = 200-230 V, 4 = 380-460 V), enclosure (1 = NEMA 1, 2 = NEMA 12, 4 = NEMA 4X indoor or NEMA 12) and finally 60 for Version 6.0 regulator firmware. That is Rockwell's key from Figure 2.1 of the GV3000/SE Hardware Reference. The GV3000/SE is a PWM drive offering flux vector control with encoder feedback, sensorless vector control, or plain V/Hz. Rockwell Automation discontinued this line, so supply is surplus and remanufactured; tell us which you will accept. Please email [email protected] to check stock for this item -- send the part number and the quantity you need and the order desk will come back with current availability, lead time and pricing, usually the same business day.
Specifications
| Drive Type | AC PWM vector / V/Hz drive |
|---|---|
| Enclosure rating | NEMA 1 |
| Input current | 159 |
| Input kVA | 127 kVA |
| Input Voltage | 380-460 V |
| Lifecycle Status | Discontinued by Rockwell Automation |
| Manufacturer Reference | GV3000/SE Hardware Reference, Table 2.1 |
| Output Current at 2 kHz | 152 A |
| Output Current at 4 kHz | 122 A |
| Output Current at 8 kHz | 91.0 A |
| Power Loss at Full Load | 2410 W |
| Power Rating, Vector | 100-125 HP |
| Regulator Firmware | Version 6.0 |
| Series | Reliance GV3000/SE |
Product details
| Manufacturer | Reliance Electric |
|---|---|
| Manufacturer part number | 125R4160 |
| Product category | Variable Frequency Drives (VFD) |
| Published specifications | 14 attributes listed |
Request a quote for this part
Email [email protected] or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for 125R4160?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email [email protected], and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 125R4160?
125R4160 is a Reliance Electric part. KKM Solutions sources Reliance Electric components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
Is 125R4160 discontinued, and can I still get one?
KKM Solutions does not publish a manufacturer lifecycle status for 125R4160 — check Reliance Electric's own product page for whether it is current, superseded, or end-of-life. It does not change what we can do: we source current-production, superseded and long-obsolete parts the same way, and where a part is genuinely unavailable we identify a form-fit-function equivalent. Send the part number through the quote form on this page, or use our obsolete part lookup at https://kkmsolutions.com/tools/obsolete-part-lookup/.
What are the key specifications of 125R4160?
Key specifications include Drive Type: AC PWM vector / V/Hz drive; Enclosure rating: NEMA 1; Input current: 159; Input kVA: 127 kVA. The full specification table on this page lists every published attribute for this part.
How quickly can 125R4160 ship?
In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Reliance Electric 1SU21002 SP500 AC Drive, 2 HP, 200-230…
Reliance Electric 7V2260 GV3000/SE AC Drive, 7.5 HP, 200-230…
Reliance Electric 1SU54001 SP500 AC Drive, 1 HP, 575…
Reliance Electric 1SU41002 SP500 AC Drive, 2 HP, 380-460…
Reliance Electric 1SU44001 SP500 AC Drive, 1 HP, 380-460…
Danfoss 131B3580 CD302 Drive, 15 kW, 380-480 V, IP55
Browse more Reliance Electric Drives & Soft Starters, or see everything from Reliance Electric.
Industrial Automation & MRO Parts