Inline Particle Monitor – iCountPD
Overview
Hydraulic fluid cleanliness plays a critical role in the performance and reliability of industrial equipment. Fluids with high levels of contamination and/or solid particulate matter can damage system components, such as pumps, actuators, or servo valves, leading to shorter maintenance intervals, added downtime, and increased costs.
The iCountPD from Parker is a highly compact, permanently mounted laser detection particle monitor designed for continuous monitoring of contamination and solid particulate levels in hydraulic fluid systems. The device represents the most up to date technology in solid particle contamination analysis and serves as a cost-effective solution to fluid management and condition monitoring in applications ranging from construction machinery, to industrial plant equipment, to test rigs.
The iCountPD is available in three configurations to meet the unique requirements of customers’ applications. Options include:
Standard iCountPD – The standard iCount PD is designed for test stand, flushing skids, filter carts and other industrial applications.
iCountPDR – The iCountPDR is designed for mobile equipment or any outside use other than hazardous environment.
iCountPDZ – The iCountPDZ is suited for applications that require a ATEX Zone II safety such as off-shore platforms or any other hazardous environment. For Zone I applications, the standard iCountPD can be used within a NEMA7 enclosure.
All iCountPD models feature an LED display, which uses three sets of lights for the indication of ISO 4406 / AS4059 and NAS1638 code figures. Individual code lights will trigger based on the customer settings. A moisture sensor is an option that can be included when specifying the icountPD. The moisture sensor reports on the saturation levels of the fluid passing through the sensing cell. The output is a linear scale, reporting within the range of 5% saturation to 100% saturation
Increased flexibility is provided by an intuitive flow control device that fits on the downstream (outlet) side of the icountPD. The device is fitted with a differential pressure valve that adjusts the system flow to a range inside the icountPD specifications. The flow control device will operate correctly between 10.3 bar (150 psi) and 200 bar (2900 psi) and the return back to an open system of 0 bar.
For portable particle monitor devices, Parker offers the iCount LaserCM and the iCountOS.
For additional information, consult the iCountPD documentation in the “Product Support” tab.
Markets:
•Agriculture
•Construction
•Oil and Gas
•Power Generation
•Marine
•Mining
•Forestry
•Industrial Plant
•Pulp and Paper
Applications:
•Deck and mobile cranes
•Firefighting equipment
•Forwarders
•Hydraulic presses
•Excavators
•Harvesters
•Waste balers
•Reach stackers
•Wheeled loaders
•Drilling equipment
•Industrial power units
•Airplanes
•Refineries
•Test rigs
•Flushing stands
•Wind turbines
Benefits:
•Enables continuous monitoring of contamination levels in hydraulic fluid systems. Dirty fluid can then be replaced and/or cleansed, leading to improved system performance and efficiency
•Independent monitoring of system contamination trends allows service personnel to optimize maintenance schedules and diagnose mechanical problems with equipment and machinery
•Compact, portable design provides ease of installation and use
•Particle monitor is inline and can be utilized while machinery is in operation, ensuring system uptime
Features:
•Warning LED or digital display indicators for Low, Medium and High contamination levels.
•Visual indicators with power and alarm output warnings.
•Moisture %RH indicator (optional).
•Fuel, Hydraulic and phosphate Ester fluid compatible construction.
•Self diagnostic software.
•Full PC/PLC integration technology such as: RS232 and 0-5Volt, 4-20mA, CAN(J1939) (Contact Parker for other options).
•Set up and Data logging support software included
•Online Flow Range via System 20 Inline Sensors (Hydraulic systems only): Size 0 = 6 to 25 L/min - (Optimum Flow = 15 L/min) Size 1 = 24 to 100 l/min - (Optimum Flow = 70 l/min) Size 2 = 170 to 380 L/min - (Optimum Flow = 250 L/min)
•Temperature: Ambient storage temperature -20°C to +40°C (-4°F to +104°F); Environment operating temperature +5°C to +60°C (+41°F to +140°F); Fluid operating temperature +5°C to +80°C (+41°F to +176°F) Wilson Company lists this item's availability as: Out of Stock.
Product details
| Manufacturer | Parker |
|---|---|
| Manufacturer part number | IPD22323110 |
| KKM catalog reference | WILSON-IPD22323110 |
| Related part numbers | 9 other part numbers in this family |
Request a quote for this part
Email [email protected] or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for IPD22323110?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email [email protected], and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the IPD22323110?
IPD22323110 is a Parker part. KKM Solutions sources Parker components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
Is IPD22323110 discontinued, and can I still get one?
KKM Solutions does not publish a manufacturer lifecycle status for IPD22323110 — check Parker's own product page for whether it is current, superseded, or end-of-life. It does not change what we can do: we source current-production, superseded and long-obsolete parts the same way, and where a part is genuinely unavailable we identify a form-fit-function equivalent. Send the part number through the quote form on this page, or use our obsolete part lookup at https://kkmsolutions.com/tools/obsolete-part-lookup/.
How quickly can IPD22323110 ship?
In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Variants & Related Part Numbers
Other Parker part numbers in this family:
- IPD22322110 — Inline Particle Monitor – iCountPD
- IPD22322130 — Inline Particle Monitor – iCountPD
- IPD22322210 — Inline Particle Monitor – iCountPD
- IPD22322230 — Inline Particle Monitor – iCountPD
- IPD22323130 — Inline Particle Monitor – iCountPD
- IPD22323210 — Inline Particle Monitor – iCountPD
- IPD22323230 — Inline Particle Monitor – iCountPD
- IPD22325110 — Inline Particle Monitor – iCountPD
- IPD22325210 — Inline Particle Monitor – iCountPD
Industrial Automation & MRO Parts