SV6151 IFM Vortex flow meter
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM SV6151 - Vortex flow meter - Material: Housing: PPS 40% glass fiber; electronics: PC 10% glass fiber; Storage Temperature: -40...85.
Overview
Part number SV6151 from IFM, listed in Flow Sensors & Meters. Specifications on file: Accuracy ± 0,3 ± 0,005 x T; Ambient temperature -15...85; Analog current output 4...20; Application for industrial applications. KKM Solutions quotes this part with pricing and availability confirmed per order.
IFM SV6151 is a Vortex flow meter catalog item from IFM. The manufacturer's published data for this part number specifies Material: Housing: PPS 40% glass fiber; electronics: PC 10% glass fiber.
Reliable detection of flow and medium temperature; Precise linearized analog output; Suitable for ultrapure water, water and water-based media; Durable and robust thanks to hydrolysis-resistant plastic; High precision of flow and temperature monitoring
Key manufacturer data on file for this item includes Storage Temperature: -40...85; Ambient temperature: -15...85; Connector: 1 x M12; coding: A; Contacts: 4, gold-plated; Installation: connection to pipe by means of an adapter; Tightening torque: 12; Protection class: III; Dimensions: 87 x 30.2 x 55.7; Application: for industrial applications; Output signal: analog signal; Product type: Vortex flow meter; Accuracy: ± 0,3 ± 0,005 x T; Response time: 0.28; (T09). See the Specifications tab on this page for the full technical table.
Specifications
| Accuracy | ± 0,3 ± 0,005 x T |
|---|---|
| Ambient temperature | -15...85 |
| Analog current output | 4...20 |
| Application | for industrial applications |
| Cavitation | P(absolute) discharge / P(difference) > 5.5 to avoid cavitation |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
| Dimensions | 87 x 30.2 x 55.7 |
| Housing | rectangular |
| Installation | connection to pipe by means of an adapter |
| Internal heating temperature probe | 1 K/mW |
| Key Features | Reliable detection of flow and medium temperature; Precise linearized analog output; Suitable for ultrapure water, water and water-based media; Durable and robust thanks to hydrolysis-resistant plastic; High precision of flow and temperature monitoring |
| Material | Housing: PPS 40% glass fiber; electronics: PC 10% glass fiber |
| Materials (wetted parts) | sensor: PPSU; Pipe section: PPS 40% glass fiber; sealing: EPDM |
| Measuring element | 1 x Pt 1000; (to DIN EN 60751, class B) |
| Measuring principle | Vortex |
| Measuring range | -15...125 |
| Media | ultra-pure water; water; glycol solutions; Coolants |
| Medium temperature | -15...125 |
| Min. insulation resistance | 100; (500 V DC) |
| MTTF | 396 |
| Number of analog outputs | 1 |
| Number of inputs and outputs | Number of analog outputs: 1 |
| Operating voltage | 8...33 DC |
| Output signal | analog signal |
| Pack quantity | 1 pcs. |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Process Connection | threaded connection G 3/4 external thread DN15 |
| Product type | Vortex flow meter |
| Protection | IP 65 |
| Protection class | III |
| Repeatability | 0,2; (% of the final value) |
| Response time | 0.28; (T09) |
| Special Feature | gold-plated contacts |
| Specification Summary | Vortex flow meter; analog signal; Measuring range 3.5...50 l/min; Medium temperature -15...125 °C; Pressure rating 16 bar; G 3/4 external thread DN15; Connector |
| Storage Temperature | -40...85 |
| Tightening torque | 12 |
| Total number of outputs | 1 |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | SV6151 |
| Product category | Flow Sensors & Meters |
| Published specifications | 37 attributes listed |
| Related part numbers | 1 other part number in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for SV6151?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SV6151?
SV6151 is made by IFM and is listed in our Flow Sensors & Meters category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SV6151, and the quote confirms condition and lead time before you order.
Is the SV6151 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the SV6151, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of SV6151?
No published lifecycle status is on file for SV6151. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of SV6151?
Key specifications include Accuracy: ± 0,3 ± 0,005 x T; Ambient temperature: -15...85; Analog current output: 4...20; Application: for industrial applications. The full specification table on this page lists every published attribute for this part.
What voltage does SV6151 use?
Per the published specification for SV6151: Operating voltage: 8...33 DC. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is SV6151 made of?
Per the published specification for SV6151: Material: Housing: PPS 40% glass fiber; electronics: PC 10% glass fiber. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can SV6151 ship?
Lead time for SV6151 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other IFM part numbers in this family:
Frequently Searched IFM Part Numbers
Related Products
IFM Vortex flow meter - SV6051
IFM Vortex flow meter - SV7051
IFM Vortex flow meter - SV5151
IFM Vortex flow meter - SV7151
IFM Vortex flow meter - SV5051
IFM Vortex flow meter - SV8051
More Flow Sensors & Meters parts
Technical Guides
Browse more IFM Sensors & Encoders, or see everything from IFM.
Industrial Automation & MRO Parts