SM7601 IFM Magnetic-inductive flow meter
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM SM7601 - Magnetic-inductive flow meter - Material: stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE; Storage Temperature: -13...176.
Overview
Part number SM7601 from IFM, listed in Inductive Proximity Sensors. Specifications on file: Accuracy ± 2,5 (Q > 0,26 gpm); Accuracy (in the measuring range) ± (0,8 % MW + 0,5 % MEW); Ambient temperature 14...140; Analog current output 4...20; (scalable). KKM Solutions quotes this part with pricing and availability confirmed per order.
The IFM SM7601 is part of the Magnetic-inductive flow meter range in our industrial catalog. The manufacturer's published data for this part number specifies Material: stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE.
Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; With switching output, analog output and pulse output; Clearly visible numerical display
Published specifications for this part include Storage Temperature: -13...176; Ambient temperature: 14...140; Connector: 1 x M12; coding: A; Contacts: 4, gold-plated; Protection class: III; Dimensions: Ø 54 / L = 110; Number of digital outputs: 2; Application: Totalizer function; for industrial applications; Output signal: switching signal; analog signal; pulse signal; IO-Link; (configurable); Product type: Magnetic-inductive flow meter; Accuracy: ± 2,5 (Q > 0,26 gpm); Response time: 0.15; (dAP = 0, T19); Communication interface: IO-Link. The complete technical table is shown in the Specifications tab on this page.
Specifications
| Accuracy | ± 2,5 (Q > 0,26 gpm) |
|---|---|
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
| Ambient temperature | 14...140 |
| Analog current output | 4...20; (scalable) |
| Analog end point | 31.5...176 |
| Analog start point | -4...140.5 |
| Analog voltage output | 0...10; (scalable) |
| Application | Totalizer function; for industrial applications |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
| Current consumption | 95; ((24 )) |
| Damping process value dAP | 0...5 |
| Delay time programmable dS, dr | 0...50 |
| Dimensions | Ø 54 / L = 110 |
| Dynamic response T05 / T09 | T09 = 20 (Q > 0,26 gpm) |
| Electrical design | PNP/NPN |
| Housing | tubular |
| In steps of | 0.5 |
| Inlet pipe length | 3 x DN |
| Inputs | counter reset |
| IO-Link revision | 1.1 |
| Key Features | Precise measurement of flow, consumption and medium temperature; High accuracy, repeatability and measurement dynamics; With switching output, analog output and pulse output; Clearly visible numerical display |
| Material | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK; FKM |
| Max. load | 500 |
| Max. voltage drop switching output DC | 2 |
| Measuring principle | magnetic-inductive |
| Measuring range | -4...176 |
| Media | Conductive liquids; water; water-based media |
| Medium temperature | 14...158 |
| Min. load resistance | 2000 |
| Min. process cycle time | 5 |
| MTTF | 145 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 18...30 DC; (to SELV/PELV) |
| Outlet pipe length | 1 x DN |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display unit |
| Permanent current rating of switching output DC | 200 |
| Power-on delay time | 5 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Process Connection | threaded connection 3/4" NPT Internal thread DN20 |
| Process data analog | 3 |
| Process data binary | 2 |
| Product type | Magnetic-inductive flow meter |
| Protection | IP 67 |
| Protection class | III |
| Pulse length | 0,005...2 |
| Pulse output | flow rate meter |
| Pulse value | 0.01...99 990 000 gal |
| Repeatability | ± 0,2% MEW |
| Required master port class | A |
| Reset point rP | -3.5...175 |
| Resolution | 0.5 |
| Response time | 0.15; (dAP = 0, T19) |
| Reverse polarity protection | yes |
| SDCI standard | IEC 61131-9 |
| Set point SP | -2.5...176 |
| Short circuit protection | yes |
| SIO mode | yes |
| Special Feature | gold-plated contacts |
| Specification Summary | Magnetic-inductive flow meter; PNP/NPN; switching signal; analog signal; pulse signal; IO-Link; Pressure rating 16 bar; 3/4" NPT Internal thread DN20; Connector |
| Storage Temperature | -13...176 |
| Total number of outputs | 2 |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | yes (non-latching) |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | SM7601 |
| Product category | Inductive Proximity Sensors |
| Published specifications | 71 attributes listed |
| Related part numbers | 2 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for SM7601?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SM7601?
SM7601 is made by IFM and is listed in our Inductive Proximity Sensors category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SM7601, and the quote confirms condition and lead time before you order.
Is the SM7601 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the SM7601, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of SM7601?
No published lifecycle status is on file for SM7601. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of SM7601?
Key specifications include Accuracy: ± 2,5 (Q > 0,26 gpm); Accuracy (in the measuring range): ± (0,8 % MW + 0,5 % MEW); Ambient temperature: 14...140; Analog current output: 4...20; (scalable). The full specification table on this page lists every published attribute for this part.
What voltage does SM7601 use?
Per the published specification for SM7601: Analog voltage output: 0...10; (scalable); Max. voltage drop switching output DC: 2. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of SM7601?
Per the published specification for SM7601: Permanent current rating of switching output DC: 200. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is SM7601 made of?
Per the published specification for SM7601: Material: stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can SM7601 ship?
Lead time for SM7601 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other IFM part numbers in this family:
Frequently Searched IFM Part Numbers
Related Products
IFM Magnetic-inductive flow meter - SM7500
IFM Magnetic-inductive flow meter - SM7604
IFM Magnetic-inductive flow meter - SM7420
IFM Magnetic-inductive flow meter - SM7621
IFM Magnetic-inductive flow meter - SM7404
IFM Magnetic-inductive flow meter - SM8000
More Inductive Proximity Sensors parts
Technical Guides
Browse more IFM Sensors & Encoders, or see everything from IFM.
Industrial Automation & MRO Parts