SA3010 IFM Flow monitor
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM SA3010 - Flow monitor - Material: stainless steel (1.4404 / 316L); PBT; PC; PA; EPDM/X; FKM; Display range: 0...12.
Overview
Part number SA3010 from IFM, listed in Flow Sensors & Meters. Specifications on file: Accuracy (in the measuring range) ± 10; Ambient temperature -20...60; Analog current output 4...20; (scalable); Analog end point AEP 4...12. KKM Solutions quotes this part with pricing and availability confirmed per order.
IFM SA3010 is a Flow monitor catalog item from IFM. The manufacturer's published data for this part number specifies Material: stainless steel (1.4404 / 316L); PBT; PC; PA; EPDM/X; FKM.
T-pieces; ((DIN 2353): QL 18-18-18 (NW 15 mm) / QL 22-18-22 (NW 19 mm) / QL 28-18-28 (NW 24 mm))
Key manufacturer data on file for this item includes Display range: 0...12; Ambient temperature: -20...60; Connector: 1 x M12; coding: A; Contacts: 4, gold-plated; Protection class: III; Dimensions: Ø 34 / L = 102; Number of digital outputs: 2; Output signal: switching signal; analog signal; (configurable); Product type: Flow monitor; Response time: 5; (10%...90%); Measuring range: 0...10; Operating voltage: 20...28 DC; Current consumption: < 80. See the Specifications tab on this page for the full technical table.
Specifications
| Accuracy (in the measuring range) | ± 10 |
|---|---|
| Ambient temperature | -20...60 |
| Analog current output | 4...20; (scalable) |
| Analog end point AEP | 4...12 |
| Analog start point ASP | 0...8 |
| Analog voltage output | 0...10; (scalable) |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
| Delay time programmable dS, dr | 0...50 |
| Dimensions | Ø 34 / L = 102 |
| Display range | 0...12 |
| Display unit | l/min; gpm; l/h; gph; m³/h |
| Electrical design | PNP/NPN |
| Housing | tubular |
| In steps of | 0.1 |
| Installation | T-pieces; ((DIN 2353): QL 18-18-18 (NW 15 mm) / QL 22-18-22 (NW 19 mm) / QL 28-18-28 (NW 24 mm)) |
| Key Features | Reliable monitoring of water in pipes; Two switching outputs, one of them programmable as analog output; Easy setting of the switch points for quick set-up; Robust housing for use in harsh industrial environments; LED display for indication of the measured value |
| Material | stainless steel (1.4404 / 316L); PBT; PC; PA; EPDM/X; FKM |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); O-ring: FKM 70 Shore A |
| Max. load | 500 |
| Max. temperature gradient of medium | 200 |
| Max. voltage drop switching output DC | 2 |
| Measuring principle | calorimetric |
| Measuring range | 0...10 |
| Media | water |
| Medium temperature | 0...80 |
| Min. load resistance | 2000 |
| MTTF | 184 |
| Number of analog outputs | 1 |
| Number of digital outputs | 2 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Operating voltage | 20...28 DC |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; (configurable) |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Parameter setting options | hysteresis / window; normally open / closed; switching logic; current/voltage output; inside pipe diameter; Start-up delay; adaptation of displayed values; display can be rotated and switched off; Display unit |
| Permanent current rating of switching output DC | 250; (per output) |
| Power-on delay time | 10 |
| Probe diameter | 14 |
| Process Connection | threaded connection M26 x 1,5 Internal thread |
| Product type | Flow monitor |
| Protection | IP 67 |
| Protection class | III |
| Reset point rP | 0...11.9 |
| Response time | 5; (10%...90%) |
| Reverse polarity protection | yes |
| Set point SP | 0.1...12 |
| Short circuit protection | yes |
| Special Feature | gold-plated contacts |
| Specification Summary | Flow monitor; PNP/NPN; switching signal; analog signal; Measuring range 0...10 l/min; Medium temperature 0...80 °C; Pressure rating 30 bar; M26 x 1,5 Internal thread; Connector |
| Total number of outputs | 2 |
| Type of short-circuit protection | yes (non-latching) |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | SA3010 |
| Product category | Flow Sensors & Meters |
| Published specifications | 52 attributes listed |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for SA3010?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the SA3010?
SA3010 is made by IFM and is listed in our Flow Sensors & Meters category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number SA3010, and the quote confirms condition and lead time before you order.
Is the SA3010 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the SA3010, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of SA3010?
No published lifecycle status is on file for SA3010. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of SA3010?
Key specifications include Accuracy (in the measuring range): ± 10; Ambient temperature: -20...60; Analog current output: 4...20; (scalable); Analog end point AEP: 4...12. The full specification table on this page lists every published attribute for this part.
What voltage does SA3010 use?
Per the published specification for SA3010: Analog voltage output: 0...10; (scalable); Max. voltage drop switching output DC: 2. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of SA3010?
Per the published specification for SA3010: Permanent current rating of switching output DC: 250; (per output). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is SA3010 made of?
Per the published specification for SA3010: Material: stainless steel (1.4404 / 316L); PBT; PC; PA; EPDM/X; FKM. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can SA3010 ship?
Lead time for SA3010 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Frequently Searched IFM Part Numbers
Related Products
IFM Flow sensor - SA2004
IFM Flow sensor - SA4100
IFM Flow sensor - SA2000
IFM Flow sensor - SA4104
IFM Flow sensor - SA4110
IFM Flow sensor - SA4114
Technical Guides
Browse more IFM Sensors & Encoders, or see everything from IFM.
Industrial Automation & MRO Parts