PA308A IFM Pressure transmitter with ceramic measuring cell
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM PA308A - Pressure transmitter with ceramic measuring cell - Material: stainless steel (1.4404 / 316L); FKM; PA; EPDM/X; Storage Temperature: -40...100.
Overview
Part number PA308A from IFM, listed in Pressure Sensors & Transmitters. Specifications on file: Ambient temperature -20...60; Analog current output 4...20; ATEX marking II 3D Ex tc IIIC T85°C Dc X; Dimensions Ø 30 / L = 75. KKM Solutions quotes this part with pricing and availability confirmed per order.
The IFM PA308A is part of the Pressure transmitter with ceramic measuring cell range in our industrial catalog. The manufacturer's published data for this part number specifies Material: stainless steel (1.4404 / 316L); FKM; PA; EPDM/X.
25...35; (recommended tightening torque Depends on lubrication, seal and pressure rating)
The specification set recorded for this part number covers Storage Temperature: -40...100; Ambient temperature: -20...60; Connector: 1 x M12; coding: A; Contacts: 4, gold-plated; Protection class: III; Dimensions: Ø 30 / L = 75; Application: for industrial applications; For applications in hazardous areas; Output signal: analog signal; Product type: Pressure transmitter with ceramic measuring cell; Operating voltage: 9.6...32 DC; Reverse polarity protection: yes; Max. load: 720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA); Repeatability: < 0,1; (with temperature fluctuations < 10 K). See the Specifications tab on this page for the full technical table.
Specifications
| Ambient temperature | -20...60 |
|---|---|
| Analog current output | 4...20 |
| Application | for industrial applications; For applications in hazardous areas |
| ATEX marking | II 3D Ex tc IIIC T85°C Dc X |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
| Dimensions | Ø 30 / L = 75 |
| Housing | tubular |
| Key Features | For applications in hazardous areas; Precise linear 4...20 mA output signal; With long-term stability thanks to high overload protection; Robust stainless steel housing for use in harsh industrial environments |
| Material | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X |
| Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM |
| Max. load | 720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA) |
| Media | liquids and gases |
| Medium temperature | -20...60 |
| Min. insulation resistance | 100; (500 V DC) |
| Min. pressure cycles | 100 million |
| MTTF | 555 |
| Number of analog outputs | 1 |
| Number of inputs and outputs | Number of analog outputs: 1 |
| Operating voltage | 9.6...32 DC |
| Output signal | analog signal |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Process Connection | threaded connection G 1/4 Internal thread |
| Product type | Pressure transmitter with ceramic measuring cell |
| Protection | IP 65; IP 67 |
| Protection class | III |
| Restrictor element integrated | no (can be retrofitted) |
| Reverse polarity protection | yes |
| Special Feature | gold-plated contacts |
| Specification Summary | Electronic pressure sensor; 0...0.25 bar; 0...250 mbar; 0...25 kpa; G 1/4 Internal thread; analog signal; 4...20 mA; Connector; -20...60 °C; IP 65; IP 67; relative pressure |
| Step response time analog output | 3 |
| Storage Temperature | -40...100 |
| Temperature coefficient span | 0,3; (0...60 °C) |
| Temperature coefficient zero point | 0,2; (0...60 °C) |
| Tightening torque | 25...35; (recommended tightening torque Depends on lubrication, seal and pressure rating) |
| Total number of outputs | 1 |
| Type of pressure | relative pressure |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | PA308A |
| Product category | Pressure Sensors & Transmitters |
| Published specifications | 38 attributes listed |
| Related part numbers | 14 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for PA308A?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the PA308A?
PA308A is made by IFM and is listed in our Pressure Sensors & Transmitters category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number PA308A, and the quote confirms condition and lead time before you order.
Is the PA308A new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the PA308A, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of PA308A?
No published lifecycle status is on file for PA308A. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of PA308A?
Key specifications include Ambient temperature: -20...60; Analog current output: 4...20; Application: for industrial applications; For applications in hazardous areas; ATEX marking: II 3D Ex tc IIIC T85°C Dc X. The full specification table on this page lists every published attribute for this part.
What voltage does PA308A use?
Per the published specification for PA308A: Operating voltage: 9.6...32 DC. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is PA308A made of?
Per the published specification for PA308A: Material: stainless steel (1.4404 / 316L); FKM; PA; EPDM/X. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can PA308A ship?
Lead time for PA308A is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other IFM part numbers in this family:
Frequently Searched IFM Part Numbers
Related Products
IFM Pressure transmitter with ceramic measuring cell - PA307A
IFM Pressure transmitter with ceramic measuring cell - PA309A
IFM Pressure transmitter with ceramic measuring cell - PA306A
IFM Pressure transmitter with ceramic measuring cell - PA30ZA
IFM Pressure transmitter with ceramic measuring cell - PA3060
IFM Pressure transmitter with ceramic measuring cell - PA6229
Technical Guides
Browse more IFM Sensors & Encoders, or see everything from IFM.
Industrial Automation & MRO Parts