NF5008 IFM Inductive NAMUR sensor
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM NF5008 - Inductive NAMUR sensor - Material: brass special coating; sensing face: PC; Ambient temperature: -20...80.
Overview
Part number NF5008 from IFM, listed in Inductive Proximity Sensors. Specifications on file: Ambient temperature -20...80; Application For applications in hazardous areas; ATEX marking II 1G Ex ia IIC T6 Ga Ta -20...70°C; Cable 6 m, PVC; 2 x 0.34 mm². KKM Solutions quotes this part with pricing and availability confirmed per order.
IFM NF5008 is an Inductive NAMUR sensor catalog item from IFM. The manufacturer's published data for this part number specifies Material: brass special coating; sensing face: PC.
For applications in hazardous areas; For connection to intrinsically safe circuits; Particularly short housing for use where space is restricted; Very high switching frequency; Robust metal housing for use in harsh industrial environments
Published specifications for this part include Ambient temperature: -20...80; Protection class: III; Dimensions: M12 x 1 / L = 30; Application: For applications in hazardous areas; Approval: PTB 01 ATEX 2191; BVS 04 ATEX E 153 X; IECEx BVS 06.0003X; TIIS TC16107; Product type: Inductive NAMUR sensor; Mounting: non-flush mountable; Cable: 6 m, PVC; 2 x 0.34 mm²; Current consumption: 2,1); Sensing range: 4; Output function: normally closed; Hysteresis: 1...15. See the Specifications tab on this page for the full technical table.
Specifications
| Ambient temperature | -20...80 |
|---|---|
| Application | For applications in hazardous areas |
| Approval | PTB 01 ATEX 2191; BVS 04 ATEX E 153 X; IECEx BVS 06.0003X; TIIS TC16107 |
| ATEX marking | II 1G Ex ia IIC T6 Ga Ta -20...70°C |
| Cable | 6 m, PVC; 2 x 0.34 mm² |
| Connection at circuit amplifier | yes |
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.4 / copper: 0.3 |
| Dimensions | M12 x 1 / L = 30 |
| Electrical design | NAMUR |
| Housing | Threaded type |
| Hysteresis | 1...15 |
| Key Features | For applications in hazardous areas; For connection to intrinsically safe circuits; Particularly short housing for use where space is restricted; Very high switching frequency; Robust metal housing for use in harsh industrial environments |
| Material | brass special coating; sensing face: PC |
| Max. internal capacitance | 141 |
| Max. internal inductance | 134 |
| Mounting | non-flush mountable |
| MTTF | 4736 |
| Nominal voltage DC | 8.2; (1kΩ) |
| Output function | normally closed |
| Pack quantity | 1 pcs. |
| Permanent current rating of switching output DC | 30; (when used outside the hazardous area) |
| Product type | Inductive NAMUR sensor |
| Protection | IP 67 |
| Protection class | III |
| Real sensing range Sr | 4 ± 10 % |
| Sensing range | 4 |
| Shock/vibration resistance | 30 g (11 ms) / 10-55 Hz (1 mm) |
| Specification Summary | Inductive sensor; M12 x 1 / L = 30 mm; Sensing range 4 mm non-flush mountable; normally closed; DC; NAMUR; 6 m PVC-Cable; IP 67; 2-wire; Ambient temperature -20...80 °C; Switching frequency 1500 Hz |
| Supply voltage DC | 7.5...30; (when used outside the hazardous area) |
| Switch-point drift | -10...10 |
| Switching amplifiers | connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW |
| Switching frequency DC | 1500 |
| Thread designation | M12 x 1 |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | NF5008 |
| Product category | Inductive Proximity Sensors |
| Published specifications | 33 attributes listed |
| Related part numbers | 10 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for NF5008?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the NF5008?
NF5008 is made by IFM and is listed in our Inductive Proximity Sensors category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number NF5008, and the quote confirms condition and lead time before you order.
Is the NF5008 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the NF5008, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of NF5008?
No published lifecycle status is on file for NF5008. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of NF5008?
Key specifications include Ambient temperature: -20...80; Application: For applications in hazardous areas; Approval: PTB 01 ATEX 2191; BVS 04 ATEX E 153 X; IECEx BVS 06.0003X; TIIS TC16107; ATEX marking: II 1G Ex ia IIC T6 Ga Ta -20...70°C. The full specification table on this page lists every published attribute for this part.
What voltage does NF5008 use?
Per the published specification for NF5008: Nominal voltage DC: 8.2; (1kΩ); Supply voltage DC: 7.5...30; (when used outside the hazardous area). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of NF5008?
Per the published specification for NF5008: Permanent current rating of switching output DC: 30; (when used outside the hazardous area). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What thread or connection does NF5008 use?
Per the published specification for NF5008: Thread designation: M12 x 1. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can NF5008 ship?
Lead time for NF5008 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other IFM part numbers in this family:
Frequently Searched IFM Part Numbers
Related Products
IFM Inductive NAMUR sensor - NF5004
IFM Inductive NAMUR sensor - NF500A
IFM Inductive NAMUR sensor - NF5003
IFM Inductive NAMUR sensor - NF5010
IFM Inductive NAMUR sensor - NF5002
IFM Inductive NAMUR sensor - NF5012
More Inductive Proximity Sensors parts
Technical Guides
Browse more IFM Sensors & Encoders, or see everything from IFM.
Industrial Automation & MRO Parts