MN206S IFM Magnetically coded sensor
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM MN206S - Magnetically coded sensor - Material: PA; Ambient temperature: -25...80.
Overview
Part number MN206S from IFM, listed in Sensors & Encoders. Specifications on file: Air pressure 80...106; Ambient temperature -25...80; Connector 1 x M8; coding: A; Contacts: 4; Design coded target. KKM Solutions quotes this part with pricing and availability confirmed per order.
The IFM MN206S is part of the Magnetically coded sensor range in our industrial catalog. The manufacturer's published data for this part number specifies Material: PA.
Actuation possible from different directions; Conceal behind stainless steel for enhanced tamper prevention; Meets the interface description CB24I from ZVEI; Highest security level according to ISO 13849-1 up to PL e in connection with an evaluation unit type G150xS / AC4x2S
Published specifications for this part include Ambient temperature: -25...80; Connector: 1 x M8; coding: A; Contacts: 4; Tightening torque: 0.8...2; Protection class: III; Dimensions: 36 x 13 x 26; Product type: Magnetically coded sensor; Mounting: non-flush mountable; Short-circuit-proof: no; Operating voltage: 24 DC; (cULus - Class 2 source required); Reverse polarity protection: no; Sensing range: 5; (with defined actuator); Design: coded target. The complete technical table is shown in the Specifications tab on this page.
Specifications
| Air pressure | 80...106 |
|---|---|
| Ambient temperature | -25...80 |
| Applications | Class C to EN 60654-1 weatherproof application |
| B10D | 20.000.000; (without load; at max. load DC 12, 24 V, 50 mA: 400.000) |
| Connector | 1 x M8; coding: A; Contacts: 4 |
| Design | coded target |
| Dimensions | 36 x 13 x 26 |
| Housing | rectangular |
| Internal resistance (Ri) | 10; (1 W) |
| Key Features | Actuation possible from different directions; Conceal behind stainless steel for enhanced tamper prevention; Meets the interface description CB24I from ZVEI; Highest security level according to ISO 13849-1 up to PL e in connection with an evaluation unit type G150xS / AC4x2S |
| Material | PA |
| Max. capacitive load CL_max | 20 |
| Max. fall time | 0.1 |
| Max. height above sea level | 2000 |
| Max. make time incl. bounce | 0.6 |
| Max. relative air humidity | briefly: 5...95 %; permanent: 5...70 % |
| MIssion time TM | ≤ 175200 |
| Mounting | non-flush mountable |
| Operating voltage | 24 DC; (cULus - Class 2 source required) |
| Output data | Interface type A |
| Output function | 2 x normally open; (potential-free) |
| Pack quantity | 1 pcs. |
| Permanent current rating of switching output DC | 50 |
| Product type | Magnetically coded sensor |
| Protection | IP 67; IP 69K |
| Protection class | III |
| Rated insulation voltage | 60 |
| Response time to safety request | 10 |
| Reverse polarity protection | no |
| Safe switching-off distance s(ar) | 15 |
| Salt spray | no |
| Sensing range | 5; (with defined actuator) |
| Short-circuit-proof | no |
| Specification Summary | Magnetically coded sensor; 36 x 13 x 26 mm; Sensing range 5 mm non-flush mountable; 2 x normally open; (potential-free); DC; M8 Connector; IP 67; IP 69K; 3-wire; Ambient temperature -25...80 °C; Switching frequency 150 Hz |
| Switching frequency DC | 150 |
| Tightening torque | 0.8...2 |
| Type of operation | permanent operation |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | MN206S |
| Product category | Sensors & Encoders |
| Published specifications | 37 attributes listed |
| Related part numbers | 7 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for MN206S?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the MN206S?
MN206S is made by IFM and is listed in our Sensors & Encoders category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number MN206S, and the quote confirms condition and lead time before you order.
Is the MN206S new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the MN206S, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of MN206S?
No published lifecycle status is on file for MN206S. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of MN206S?
Key specifications include Air pressure: 80...106; Ambient temperature: -25...80; Applications: Class C to EN 60654-1 weatherproof application; B10D: 20.000.000; (without load; at max. load DC 12, 24 V, 50 mA: 400.000). The full specification table on this page lists every published attribute for this part.
What voltage does MN206S use?
Per the published specification for MN206S: Operating voltage: 24 DC; (cULus - Class 2 source required); Rated insulation voltage: 60. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of MN206S?
Per the published specification for MN206S: Permanent current rating of switching output DC: 50. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is MN206S made of?
Per the published specification for MN206S: Material: PA. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can MN206S ship?
Lead time for MN206S is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other IFM part numbers in this family:
Frequently Searched IFM Part Numbers
Related Products
IFM cylinder sensor with IO-Link - MK5908
IFM Magnetically coded sensor - MN207S
IFM cylinder sensor with IO-Link - MK5906
IFM Magnetically coded sensor - MN508S
IFM cylinder sensor with IO-Link - MK5905
IFM RFID-coded safety sensor - MN700S
More Sensors & Encoders parts
Technical Guides
Browse more IFM Sensors & Encoders, or see everything from IFM.
Industrial Automation & MRO Parts