LR3000 IFM Continuous level sensor (guided wave radar)
KKM Solutions is an independent parts distributor, not an authorized IFM dealer — how we source.
IFM LR3000 - Continuous level sensor (guided wave radar) - Storage Temperature: -40...80; Ambient temperature: -25...60.
Overview
Part number LR3000 from IFM, listed in Level Sensors. Specifications on file: Ambient temperature -25...60; Analog current output 4...20, invertible; (scalable); Analog voltage output 0...10, invertible; (scalable); Application for industrial applications. KKM Solutions quotes this part with pricing and availability confirmed per order.
This listing covers the IFM LR3000, a part number in the Continuous level sensor (guided wave radar) category. The manufacturer's published data for this part number specifies Storage Temperature: -40...80.
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PBT; PC; PEI; TPE-V
Key manufacturer data on file for this item includes Ambient temperature: -25...60; Connector: 1 x M12; coding: A; Contacts: 4, gold-plated; Protection class: III; Dimensions: Ø 50 / L = 99; Number of digital outputs: 1; Application: for industrial applications; Output signal: switching signal; analog signal; IO-Link; Product type: Continuous level sensor (guided wave radar); Communication interface: IO-Link; Operating voltage: 18...30 DC; Current consumption: < 30; Reverse polarity protection: yes. The complete technical table is shown in the Specifications tab on this page.
Specifications
| Active range A | L-40; (when set to oil and oil based media: L-60) |
|---|---|
| Ambient temperature | -25...60 |
| Analog current output | 4...20, invertible; (scalable) |
| Analog voltage output | 0...10, invertible; (scalable) |
| Application | for industrial applications |
| Cannot be used for | See the operating instructions, chapter "Function and features". |
| Communication interface | IO-Link |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |
| Dielectric constant of the medium | ≥ 1,8; (for media with a dielectric constant of 1.8...5 (e.g. oils), a coaxial pipe is needed for operation) |
| Dimensions | Ø 50 / L = 99 |
| Electrical design | PNP |
| Full signal (current) | 20 |
| Full signal (voltage) | 10 |
| Hysteresis | > 5 |
| In steps of | 5 |
| Inactive range I1 / I2 | 30 / 10; (when set to oil and oil based media: 30 / 30) |
| IO-Link revision | 1.1 |
| Key Features | For the reliable level control in tanks and containers; Suitable for water, oils and coolants; Clearly visible numerical display; Modular system consisting of evaluation unit and probe; Probes may be cut to length for application flexibility |
| Material | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PBT; PC; PEI; TPE-V |
| Materials (wetted parts) | stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; sealing: NBR fiber-reinforced |
| MAWP (for applications according to CRN) | 16 |
| Max. load | 500 |
| Max. voltage drop switching output DC | 2.5 |
| Measuring error | ± 7 |
| Measuring principle | guided wave radar |
| Media | Liquids |
| Min. load resistance | 2000 |
| Min. process cycle time | 2.3 |
| MTTF | 196 |
| Notes | Please see the technical note under "Downloads"; For high process temperatures: The temperature at the process connection is decisive. The actual medium temperature may be higher. |
| Number of analog outputs | 1 |
| Number of digital outputs | 1 |
| Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
| Offset error | 5 |
| Operating voltage | 18...30 DC |
| Output function | normally open / closed; (configurable) |
| Output signal | switching signal; analog signal; IO-Link |
| Overload protection | yes |
| Pack quantity | 1 pcs. |
| Permanent current rating of switching output DC | 200 |
| Pressure Rating | 16 |
| Probe length (L) | 100...1600 |
| Process Connection | threaded connection G 3/4 external thread |
| Process data analog | 1 |
| Process data binary | 1 |
| Product type | Continuous level sensor (guided wave radar) |
| Protection | IP 67 |
| Protection class | III |
| Recommended media | water; water-based media; oils; oil-based media |
| Repeatability | ± 5 |
| Required master port class | A |
| Reset point rP | 10... L-35 |
| Resolution | 1 |
| Reverse polarity protection | yes |
| Sampling rate | 4 |
| SDCI standard | IEC 61131-9 CDV |
| Set point SP | 15...L-30 |
| Short circuit protection | yes |
| SIO mode | yes |
| Special Feature | gold-plated contacts |
| Specification Summary | Electronic level sensor; PNP; switching signal; analog signal; IO-Link; Pressure rating 16 bar; G 3/4 external thread; Connector |
| Storage Temperature | -40...80 |
| Temperature drift per 10 K | ± 0.2 |
| Total number of outputs | 2 |
| Transmission type | COM2 (38,4 kBaud) |
| Type of short-circuit protection | thermal, pulsed |
| Vacuum resistance | -1000 |
| Zero signal (current) | 4.0 |
| Zero signal (voltage) | 0.000000 |
Product details
| Manufacturer | IFM |
|---|---|
| Manufacturer part number | LR3000 |
| Product category | Level Sensors |
| Published specifications | 69 attributes listed |
| Related part numbers | 2 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for LR3000?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the LR3000?
LR3000 is made by IFM and is listed in our Level Sensors category. KKM Solutions is an independent distributor, not an authorized IFM dealer: we source the exact IFM part number LR3000, and the quote confirms condition and lead time before you order.
Is the LR3000 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the LR3000, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of LR3000?
No published lifecycle status is on file for LR3000. IFM lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of LR3000?
Key specifications include Active range A: L-40; (when set to oil and oil based media: L-60); Ambient temperature: -25...60; Analog current output: 4...20, invertible; (scalable); Analog voltage output: 0...10, invertible; (scalable). The full specification table on this page lists every published attribute for this part.
What voltage does LR3000 use?
Per the published specification for LR3000: Full signal (voltage): 10; Max. voltage drop switching output DC: 2.5. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of LR3000?
Per the published specification for LR3000: Permanent current rating of switching output DC: 200. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is LR3000 made of?
Per the published specification for LR3000: Material: stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PBT; PC; PEI; TPE-V. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can LR3000 ship?
Lead time for LR3000 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other IFM part numbers in this family:
Frequently Searched IFM Part Numbers
Related Products
IFM Continuous level sensor (guided wave radar) - LR2750
IFM Continuous level sensor (guided wave radar) - LR3009
IFM Continuous level sensor (guided wave radar) - LR2350
IFM Continuous level sensor (guided wave radar) - LR3020
IFM Continuous level sensor (guided wave radar) - LR2050
IFM Continuous level sensor (guided wave radar) - LR3300
More Level Sensors parts
Technical Guides
Browse more IFM Sensors & Encoders, or see everything from IFM.
Industrial Automation & MRO Parts