Endress+Hauser Absolute andgauge pressureCerabar PMC71
| Accuracy | Standard: 0.05% Platinum: up to 0.025% |
|---|---|
| Ambient temperature | -40°C...85°C (-40°F...185°F) |
| Application limits | Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure |
| Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC |
| Characteristic | Digital transmitter with capacitive sensor and ceramic membrane Modular transmitter Long term stability Enhanced safety via self diagnostic functions Secondary process barrier |
| Characteristic / Application | Digital transmitter with capacitive sensor and ceramic membrane Modular transmitter Long term stability Enhanced safety via self diagnostic functions Secondary process barrier |
| Communication | 4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Design approvals | EN 10204-3.1 |
| Drinking water approvals | NSF |
| Fill fluid | none, dry measuring cell |
| Hygienic approvals | 3A, EHEDG |
| Long term stability | 0,05% of URL/year |
| Main wetted parts | Ceraphire ceramic Alloy C 316L Monel PVDF |
| Marine approval | GL/ ABS |
| Marine approvals | GL/ ABS |
| Material gasket | Viton, EPDM, Chemraz, Kalrez, NBR |
| Material housing | Die-cast aluminum, AISI 316L |
| Material process membrane | Ceramic |
| Max. measurement distance | 400m (1312ft) H2O |
| Max. overpressure limit | 60 bar (900 psi) |
| Max. Turn down | 100:1 |
| Measuring cell | 100 mbar...40 bar (1.5 psi...600 psi) relative/ absolute |
| Measuring principle | Absolute and gauge pressure |
| Options | HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
| Pressure measuring range | 100mbar...40bar (1.5psi...600psi) |
| Process Connection | Threads Flanges Tri-Clamp ISO2852 Hygienic connections |
| Process connection hygienic | Tri-Clamp DIN11851 Varivent N SMS DRD |
| Process pressure / max. overpressure limit | 60bar (900psi) |
| Process temperature | -40°C...150°C (-40°F...302°F) |
| Reference Accuracy | Standard: 0.05% Platinum: up to 0.025% |
| Smallest calibratable span | 5 mbar (0.075 psi) |
| Specialities | diagnostic functionalities different languages in software |
| Successor | PMC71B |
| Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC |
| Supply voltage | 4...20 mA HART 10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
| Vacuum resistance | 0 mbar abs. |
Frequently Asked Questions
How do I get pricing for PMC71?
KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the PMC71?
PMC71 is a Endress+Hauser part. KKM Solutions sources Endress+Hauser components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.
What are the key specifications of PMC71?
Key specifications include Accuracy: Standard: 0.05% Platinum: up to 0.025%; Ambient temperature: -40°C...85°C (-40°F...185°F); Application limits: Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure; Certificates / Approvals: ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC. The full specification table on this page lists every published attribute for this part.
How quickly can PMC71 ship?
In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.
Related Products
Endress+Hauser Endress+Hauser Cerabar PMC51B - pressure transmitter
Endress+Hauser Endress+Hauser Cerabar PMC71B - pressure transmitter
Endress+Hauser Endress+Hauser Absolute andgauge pressureCerabar PMC51
Endress+Hauser Endress+Hauser Deltabar PMD50 - differential pressure transmitter
Endress+Hauser Endress+Hauser Differential pressureDeltabar PMD55
Endress+Hauser
Industrial & MRO Parts