PMC71 Endress+Hauser Absolute andgauge pressureCerabar
KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.
Endress+Hauser PMC71 - Pressure - Ambient temperature: -40°C...85°C (-40°F...185°F); Material housing: Die-cast aluminum, AISI 316L; Options: HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing.
Overview
Part number PMC71 from Endress+Hauser, listed in Pressure Sensors & Transmitters. Specifications on file: Accuracy Standard: 0.05% Platinum: up to 0.025%; Ambient temperature -40°C...85°C (-40°F...185°F); Design approvals EN 10204-3.1; Drinking water approvals NSF. KKM Solutions quotes this part with pricing and availability confirmed per order.
The Endress+Hauser PMC71 is part of the Pressure range in our industrial catalog. The manufacturer's published data for this part number specifies Ambient temperature: -40°C...85°C (-40°F...185°F) and Material housing: Die-cast aluminum, AISI 316L.
4...20 mA HART 10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex)
Published specifications for this part include Options: HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing; Marine approval: GL/ ABS; Communication: 4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus; Accuracy: Standard: 0.05% Platinum: up to 0.025%; Measuring principle: Absolute and gauge pressure; Process Connection: Threads Flanges Tri-Clamp ISO2852 Hygienic connections; Process temperature: -40°C...150°C (-40°F...302°F); Process pressure / max. overpressure limit: 60bar (900psi); Main wetted parts: Ceraphire ceramic Alloy C 316L Monel PVDF; Certificates / Approvals: ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC; Specialities: diagnostic functionalities different languages in software; Process connection hygienic: Tri-Clamp DIN11851 Varivent N SMS DRD. The complete technical table is shown in the Specifications tab on this page.
Specifications
| Accuracy | Standard: 0.05% Platinum: up to 0.025% |
|---|---|
| Ambient temperature | -40°C...85°C (-40°F...185°F) |
| Application limits | Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure |
| Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC |
| Characteristic | Digital transmitter with capacitive sensor and ceramic membrane Modular transmitter Long term stability Enhanced safety via self diagnostic functions Secondary process barrier |
| Characteristic / Application | Digital transmitter with capacitive sensor and ceramic membrane Modular transmitter Long term stability Enhanced safety via self diagnostic functions Secondary process barrier |
| Communication | 4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Design approvals | EN 10204-3.1 |
| Drinking water approvals | NSF |
| Fill fluid | none, dry measuring cell |
| Hygienic approvals | 3A, EHEDG |
| Long term stability | 0,05% of URL/year |
| Main wetted parts | Ceraphire ceramic Alloy C 316L Monel PVDF |
| Marine approval | GL/ ABS |
| Marine approvals | GL/ ABS |
| Material gasket | Viton, EPDM, Chemraz, Kalrez, NBR |
| Material housing | Die-cast aluminum, AISI 316L |
| Material process membrane | Ceramic |
| Max. measurement distance | 400m (1312ft) H2O |
| Max. overpressure limit | 60 bar (900 psi) |
| Max. Turn down | 100:1 |
| Measuring cell | 100 mbar...40 bar (1.5 psi...600 psi) relative/ absolute |
| Measuring principle | Absolute and gauge pressure |
| Options | HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
| Pressure measuring range | 100mbar...40bar (1.5psi...600psi) |
| Process Connection | Threads Flanges Tri-Clamp ISO2852 Hygienic connections |
| Process connection hygienic | Tri-Clamp DIN11851 Varivent N SMS DRD |
| Process pressure / max. overpressure limit | 60bar (900psi) |
| Process temperature | -40°C...150°C (-40°F...302°F) |
| Reference Accuracy | Standard: 0.05% Platinum: up to 0.025% |
| Smallest calibratable span | 5 mbar (0.075 psi) |
| Specialities | diagnostic functionalities different languages in software |
| Successor | PMC71B |
| Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC |
| Supply voltage | 4...20 mA HART 10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
| Vacuum resistance | 0 mbar abs. |
Product details
| Manufacturer | Endress+Hauser |
|---|---|
| Manufacturer part number | PMC71 |
| Product category | Pressure Sensors & Transmitters |
| Published specifications | 36 attributes listed |
| Related part numbers | 1 other part number in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for PMC71?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the PMC71?
PMC71 is made by Endress+Hauser and is listed in our Pressure Sensors & Transmitters category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number PMC71, and the quote confirms condition and lead time before you order.
Is the PMC71 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is surplus, new-old-stock, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the PMC71, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of PMC71?
No published lifecycle status is on file for PMC71. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of PMC71?
Key specifications include Accuracy: Standard: 0.05% Platinum: up to 0.025%; Ambient temperature: -40°C...85°C (-40°F...185°F); Application limits: Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure; Certificates / Approvals: ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC. The full specification table on this page lists every published attribute for this part.
What voltage does PMC71 use?
Per the published specification for PMC71: Supply voltage: 4...20 mA HART 10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can PMC71 ship?
Lead time for PMC71 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other Endress+Hauser part numbers in this family:
Related Products
Endress+Hauser Endress+Hauser Cerabar PMC51B - pressure transmitter
Endress+Hauser Endress+Hauser Cerabar PMC71B - pressure transmitter
Endress+Hauser Endress+Hauser Absolute andgauge pressureCerabar PMC51
Endress+Hauser Endress+Hauser Deltabar PMD50 - differential pressure transmitter
Endress+Hauser Endress+Hauser Absolute and gauge pressureCerabar PMC21
Endress+Hauser Endress+Hauser Differential pressureDeltabar PMD55
Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.