CPS77E Endress+Hauser Digital non-glass pH sensor Memosens
KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.
Endress+Hauser CPS77E - Liquid analysis - Connection: Inductive, contactless connection head with Memosens 2.0 technology; Measuring range: pH 0 to 14; Design: Design.
Overview
Part number CPS77E from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Design Design; Ingress protection IP 68; Measuring principle Measuring principle; Measuring range pH 0 to 14. KKM Solutions quotes this part with pricing and availability confirmed per order.
In our catalog, the CPS77E from Endress+Hauser is listed under the Liquid analysis category. The manufacturer's published data for this part number specifies Connection: Inductive, contactless connection head with Memosens 2.0 technology and Measuring range: pH 0 to 14.
Sensor shaft: PEEK Sealings: FFKM Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide
Published specifications for this part include Design: Design; Measuring principle: Measuring principle; Process pressure: Max. 11 bar abs at 100 °C (Max. 160 psi at 212 °F); Ingress protection: IP 68; Process temperature: -15 to 135°C (5 to 275°F); Temperature sensor: Pt1000; Reference: Stabilized gel reference system. See the Specifications tab on this page for the full technical table.
Specifications
| Application | Hygienic and sterile applications (sterilizable, autoclavable): - Bioreactor/fermenter - Biotechnology - Pharmaceutical - Food |
|---|---|
| Characteristic | Digital, sterilizable and autoclavable pH electrode for hygienic production processes with bacteria tight ceramic junction |
| Connection | Inductive, contactless connection head with Memosens 2.0 technology |
| Design | Design |
| Dimension | Diameter: 12 mm (0.47 inch) Shaft lengths: 120, 225 and 360 mm (4.72, 8.86 and 14.2 inch) |
| Ex certification | With the following approvals for use in potentially explosive areas of Zone 0, Zone 1 and Zone 2: ATEX, IECEx, CSA C / US, NEPSI, JPN Ex, INMETRO, UKCA and Korea Ex |
| Ingress protection | IP 68 |
| Material | Sensor shaft: PEEK Sealings: FFKM Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
| Measuring principle | Measuring principle |
| Measuring range | pH 0 to 14 |
| Process pressure | Max. 11 bar abs at 100 °C (Max. 160 psi at 212 °F) |
| Process temperature | -15 to 135°C (5 to 275°F) |
| Reference | Stabilized gel reference system |
| Temperature sensor | Pt1000 |
Product details
| Manufacturer | Endress+Hauser |
|---|---|
| Manufacturer part number | CPS77E |
| Product category | Vision, Measurement & Identification |
| Published specifications | 14 attributes listed |
| Related part numbers | 9 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for CPS77E?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the CPS77E?
CPS77E is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CPS77E, and the quote confirms condition and lead time before you order.
Is the CPS77E new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the CPS77E, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of CPS77E?
No published lifecycle status is on file for CPS77E. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of CPS77E?
Key specifications include Application: Hygienic and sterile applications (sterilizable, autoclavable): - Bioreactor/fermenter - Biotechnology - Pharmaceutical - Food; Characteristic: Digital, sterilizable and autoclavable pH electrode for hygienic production processes with bacteria tight ceramic junction; Connection: Inductive, contactless connection head with Memosens 2.0 technology; Design: Design. The full specification table on this page lists every published attribute for this part.
What is the IP rating of CPS77E?
Per the published specification for CPS77E: Ingress protection: IP 68. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is CPS77E made of?
Per the published specification for CPS77E: Material: Sensor shaft: PEEK Sealings: FFKM Metal lead: Ag/AgCl Open aperture: Ceramic junction, zirconium dioxide O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can CPS77E ship?
Lead time for CPS77E is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other Endress+Hauser part numbers in this family:
Frequently Searched Endress+Hauser Part Numbers
Related Products
Endress+Hauser Endress+Hauser Combined pH/ORP sensorMemosens CPS76E
Endress+Hauser Endress+Hauser Analog pH sensorOrbipore CPS91
Endress+Hauser Endress+Hauser Memosens CPS76D
Endress+Hauser Endress+Hauser Orbipore CPS91D
Endress+Hauser Endress+Hauser Digital ORP sensorMemosens CPS72E
Endress+Hauser Endress+Hauser Digital pH sensorMemosens CPS91E
More Vision, Measurement & Identification parts
Technical Guides
Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.