Skip to content
Stock is confirmed when you order, and we will advise you as soon as your order is confirmed. Need help with a part? Email orderdesk@kkmsolutions.com.
Ships worldwide — lead time quoted per part (825) 454-5367 Order desk 24/7 orderdesk@kkmsolutions.com
KKM Industrial and Automation Solutions Industrial Automation & MRO Parts Line down? Call the order desk (825) 454-536724/7
Call the order desk Get a quote
Endress+Hauser Analog conductivity sensorIndumax CLS52

CLS52 Endress+Hauser Analog conductivity sensorIndumax

Brand: Endress+Hauser SKU: CLS52 Mfr Part #: CLS52

KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.

Ships worldwide — lead time quoted per part

Endress+Hauser CLS52 - Liquid analysis - Material: Sensor: PEEK Heat contact nut: stainless steel 1.4435 Sealing: Chemraz; Application: Food, pharmaceuticals; Measuring range: 0.1 to 2000 mS/cm.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number CLS52 from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Application Food, pharmaceuticals; Certificates, declarations and approvals Calibration certification.; Ex certification not available as Ex version; Ingress protection IP67. KKM Solutions quotes this part with pricing and availability confirmed per order.

In our catalog, the CLS52 from Endress+Hauser is listed under the Liquid analysis category. The manufacturer's published data for this part number specifies Material: Sensor: PEEK Heat contact nut: stainless steel 1.4435 Sealing: Chemraz and Application: Food, pharmaceuticals.

Process connections: dairy fitting, Clamp, thread 1,5", Varivent, APV, Perlick, SMS cable: fixed cable connection.

The specification set recorded for this part number covers Measuring range: 0.1 to 2000 mS/cm; Measuring principle: Inductive conductivity measurement.; Dimension: Coil: outside diameter: appr. 47 mm inside diameter: appr. 15 mm; Process pressure: Max. 16 bar at 90 °C (Max. 232 psi at 194 °F); Ingress protection: IP67; Process temperature: Max. 125°C (short time up to 140°C) max. 257°F (short time up to 284°F); Temperature sensor: Integrated Pt100 in a heat contact nut; Certificates, declarations and approvals: Calibration certification.; Ex certification: not available as Ex version. See the Specifications tab on this page for the full technical table.

Specifications

Application Food, pharmaceuticals
Certificates, declarations and approvals Calibration certification.
Characteristic Hygienic inductive measuring cell for conductivity measurements, concentration control, CIP-control, cleaning and phase separation.
Connection Process connections: dairy fitting, Clamp, thread 1,5", Varivent, APV, Perlick, SMS cable: fixed cable connection.
Design Hygienic inductive conductivity cell with an outside temperature sensor for a faster temperature reading.
Dimension Coil: outside diameter: appr. 47 mm inside diameter: appr. 15 mm
Ex certification not available as Ex version
Ingress protection IP67
Material Sensor: PEEK Heat contact nut: stainless steel 1.4435 Sealing: Chemraz
Measuring principle Inductive conductivity measurement.
Measuring range 0.1 to 2000 mS/cm
Process pressure Max. 16 bar at 90 °C (Max. 232 psi at 194 °F)
Process temperature Max. 125°C (short time up to 140°C) max. 257°F (short time up to 284°F)
Temperature sensor Integrated Pt100 in a heat contact nut

Product details

Manufacturer Endress+Hauser
Manufacturer part number CLS52
Product category Vision, Measurement & Identification
Published specifications 14 attributes listed
Related part numbers 4 other part numbers in this family

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for CLS52?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the CLS52?

CLS52 is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CLS52, and the quote confirms condition and lead time before you order.

Is the CLS52 new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is surplus, new-old-stock, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the CLS52, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of CLS52?

No published lifecycle status is on file for CLS52. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of CLS52?

Key specifications include Application: Food, pharmaceuticals; Certificates, declarations and approvals: Calibration certification.; Characteristic: Hygienic inductive measuring cell for conductivity measurements, concentration control, CIP-control, cleaning and phase separation.; Connection: Process connections: dairy fitting, Clamp, thread 1,5", Varivent, APV, Perlick, SMS cable: fixed cable connection.. The full specification table on this page lists every published attribute for this part.

What is the IP rating of CLS52?

Per the published specification for CLS52: Ingress protection: IP67. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

What material is CLS52 made of?

Per the published specification for CLS52: Material: Sensor: PEEK Heat contact nut: stainless steel 1.4435 Sealing: Chemraz. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How quickly can CLS52 ship?

Lead time for CLS52 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Variants & Related Part Numbers

Other Endress+Hauser part numbers in this family:

Related Products

Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.