Skip to content
Stock is confirmed when you order, and we will advise you as soon as your order is confirmed. Need help with a part? Email orderdesk@kkmsolutions.com.
Ships worldwide — lead time quoted per part (825) 454-5367 Order desk 24/7 orderdesk@kkmsolutions.com
KKM Industrial and Automation Solutions Industrial Automation & MRO Parts Line down? Call the order desk (825) 454-536724/7
Call the order desk Get a quote
Endress+Hauser Digital conductivity sensor Memosens CLL47E

CLL47E Endress+Hauser Digital conductivity sensor Memosens

Brand: Endress+Hauser SKU: CLL47E Mfr Part #: CLL47E

KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.

Ships worldwide — lead time quoted per part

Endress+Hauser CLL47E - Liquid analysis - Material: Stainless steel, ceramic, platinum; Connection: Inductive, digital connection head with Memosens 2.0 technology; Measuring range: 5 μS/cm to 200 mS/cm.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number CLL47E from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Ingress protection IP68; Material Stainless steel, ceramic, platinum; Measuring principle Conductive; Measuring range 5 μS/cm to 200 mS/cm. KKM Solutions quotes this part with pricing and availability confirmed per order.

This listing covers the Endress+Hauser CLL47E, a part number in the Liquid analysis category. The manufacturer's published data for this part number specifies Material: Stainless steel, ceramic, platinum and Connection: Inductive, digital connection head with Memosens 2.0 technology.

Measurements where a broad conductivity measurement range in one system is needed

Published specifications for this part include Measuring range: 5 μS/cm to 200 mS/cm; Measuring principle: Conductive; Dimension: Diameter: 12 mm (0.47 inch) Shaft length: 120 mm (4.72 inch); Process pressure: 1 bar, not intended for continuous measurement in process; Ingress protection: IP68; Process temperature: 0 to 100 °C (32 to 212 °F); Temperature sensor: Pt1000. The complete technical table is shown in the Specifications tab on this page.

Specifications

Application Measurements where a broad conductivity measurement range in one system is needed
Characteristic Digital Memsoens 2.0 conductive conductivity sensor with four platinum electrodes for a broad measuring range.
Connection Inductive, digital connection head with Memosens 2.0 technology
Dimension Diameter: 12 mm (0.47 inch) Shaft length: 120 mm (4.72 inch)
Ingress protection IP68
Material Stainless steel, ceramic, platinum
Measuring principle Conductive
Measuring range 5 μS/cm to 200 mS/cm
Process pressure 1 bar, not intended for continuous measurement in process
Process temperature 0 to 100 °C (32 to 212 °F)
Temperature sensor Pt1000

Product details

Manufacturer Endress+Hauser
Manufacturer part number CLL47E
Product category Vision, Measurement & Identification
Published specifications 11 attributes listed

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for CLL47E?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the CLL47E?

CLL47E is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CLL47E, and the quote confirms condition and lead time before you order.

Is the CLL47E new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the CLL47E, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of CLL47E?

No published lifecycle status is on file for CLL47E. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of CLL47E?

Key specifications include Application: Measurements where a broad conductivity measurement range in one system is needed; Characteristic: Digital Memsoens 2.0 conductive conductivity sensor with four platinum electrodes for a broad measuring range.; Connection: Inductive, digital connection head with Memosens 2.0 technology; Dimension: Diameter: 12 mm (0.47 inch) Shaft length: 120 mm (4.72 inch). The full specification table on this page lists every published attribute for this part.

What is the IP rating of CLL47E?

Per the published specification for CLL47E: Ingress protection: IP68. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

What material is CLL47E made of?

Per the published specification for CLL47E: Material: Stainless steel, ceramic, platinum. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How quickly can CLL47E ship?

Lead time for CLL47E is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Frequently Searched Endress+Hauser Part Numbers

Related Products

Technical Guides

All Sensors & Measurement articles ›

Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.