CAS80E Endress+Hauser Spectrometer Memosens Wave
KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.
Endress+Hauser CAS80E - Liquid analysis - Material: Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM; Size: 571.4 x 40 mm 21.5 x 1.6 in; Ambient temperature: -20 to 60°C -4 to 140 °F.
Overview
Part number CAS80E from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Ambient temperature -20 to 60°C -4 to 140 °F; Connection G1 and NPT 3/4"; Design 40 mm; Dimension 571.4 x 40 mm 21.5 x 1.6 in. KKM Solutions quotes this part with pricing and availability confirmed per order.
This listing covers the Endress+Hauser CAS80E, a part number in the Liquid analysis category. The manufacturer's published data for this part number specifies Material: Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM and Size: 571.4 x 40 mm 21.5 x 1.6 in.
Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen
Published specifications for this part include Ambient temperature: -20 to 60°C -4 to 140 °F; Installation: Insitu (immersion in process), extractive with sample and flow cell; Application: Monitoring of WWTP in- and outlet Drinking water and surface water; Connection: G1 and NPT 3/4"; Design: 40 mm; Measuring principle: UV absorbance; Dimension: 571.4 x 40 mm 21.5 x 1.6 in; Process pressure: 0.5 to 10 bar abs. 7.3 to 145 psi; Ingress protection: IP68; Process temperature: 0 to 50°C 32 to 122 °F; Specials: G1, NPT3/4 IP68 (1m/3,3ft) water column with 1N KCl during 60 days; Measuring method: UV/VIS Absorbance at 200 to 800 nm. See the Specifications tab on this page for the full technical table.
Specifications
| Ambient temperature | -20 to 60°C -4 to 140 °F |
|---|---|
| Application | Monitoring of WWTP in- and outlet Drinking water and surface water |
| Characteristic | Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color |
| Connection | G1 and NPT 3/4" |
| Design | 40 mm |
| Dimension | 571.4 x 40 mm 21.5 x 1.6 in |
| Ingress protection | IP68 |
| Installation | Insitu (immersion in process), extractive with sample and flow cell |
| Material | Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM |
| Measuring method | UV/VIS Absorbance at 200 to 800 nm |
| Measuring principle | UV absorbance |
| Measuring range | Depending on the path length and the application the measuring range vary: TOCeq: 0 to 400 mg/l CODeq: 0 to 20 000 mg/l BODeq: 0 to 5000 mg/l SAC254: 0 to 1000 /m TU: 0 to 800 FAU TSS: 0 to 10 000 mg/l NO3-N: 0 to 500 mg/l APHA/Hazen: 0 to 500 Hazen |
| Process pressure | 0.5 to 10 bar abs. 7.3 to 145 psi |
| Process temperature | 0 to 50°C 32 to 122 °F |
| Size | 571.4 x 40 mm 21.5 x 1.6 in |
| Specials | G1, NPT3/4 IP68 (1m/3,3ft) water column with 1N KCl during 60 days |
| Temperature sensor | -20 to 60°C -4 to 140 °F |
Product details
| Manufacturer | Endress+Hauser |
|---|---|
| Manufacturer part number | CAS80E |
| Product category | Vision, Measurement & Identification |
| Published specifications | 17 attributes listed |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for CAS80E?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the CAS80E?
CAS80E is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CAS80E, and the quote confirms condition and lead time before you order.
Is the CAS80E new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the CAS80E, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of CAS80E?
No published lifecycle status is on file for CAS80E. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of CAS80E?
Key specifications include Ambient temperature: -20 to 60°C -4 to 140 °F; Application: Monitoring of WWTP in- and outlet Drinking water and surface water; Characteristic: Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color; Connection: G1 and NPT 3/4". The full specification table on this page lists every published attribute for this part.
What is the IP rating of CAS80E?
Per the published specification for CAS80E: Ingress protection: IP68. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What material is CAS80E made of?
Per the published specification for CAS80E: Material: Housing: stainless steel or titanium Windows: sapphire or quartz O-rings: EPDM. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can CAS80E ship?
Lead time for CAS80E is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Frequently Searched Endress+Hauser Part Numbers
Related Products
Endress+Hauser Endress+Hauser STIP-scan CAS74
Endress+Hauser Endress+Hauser Stamoclean CAT221
Endress+Hauser Endress+Hauser Digital nitrate or SAC sensor Viomax CAS51D
Endress+Hauser Endress+Hauser Stamoclean CAT411
Endress+Hauser Endress+Hauser Digital ammonium and nitrate sensor ISEmax CAS40D
Endress+Hauser Endress+Hauser Stamoclean CAT430
More Vision, Measurement & Identification parts
Technical Guides
Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.
Industrial Automation & MRO Parts