Skip to content
Stock is confirmed when you order, and we will advise you as soon as your order is confirmed. Need help with a part? Email orderdesk@kkmsolutions.com.
Ships worldwide — lead time quoted per part (825) 454-5367 Order desk 24/7 orderdesk@kkmsolutions.com
KKM Industrial and Automation Solutions Industrial Automation & MRO Parts Line down? Call the order desk (825) 454-536724/7
Call the order desk Get a quote
Endress+Hauser High temperature TOC analyzer CA72TOC

CA72TOC Endress+Hauser High temperature TOC analyzer

Brand: Endress+Hauser SKU: CA72TOC Mfr Part #: CA72TOC

KKM Solutions is an independent parts distributor, not an authorized Endress+Hauser dealer — how we source.

Ships worldwide — lead time quoted per part

Endress+Hauser CA72TOC - Liquid analysis - Size: 1558 x 785 x 400 mm 61.3 x 30.9 x 15.8 inch; Ambient temperature: 5 to 35 °C (41 to 95 °F); Power Supply: 115 VAC, 230 VAC, 50/60Hz.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number CA72TOC from Endress+Hauser, listed in Vision, Measurement & Identification. Specifications on file: Ambient temperature 5 to 35 °C (41 to 95 °F); Design IP54; Measuring principle UV photometric; Power Supply 115 VAC, 230 VAC, 50/60Hz. KKM Solutions quotes this part with pricing and availability confirmed per order.

This listing covers the Endress+Hauser CA72TOC, a part number in the Liquid analysis category. The manufacturer's published data for this part number specifies Size: 1558 x 785 x 400 mm 61.3 x 30.9 x 15.8 inch and Ambient temperature: 5 to 35 °C (41 to 95 °F).

Industrial wastewater monitoring Control of process wastewater Monitoring of industrial surface water Recording of the carbon load to control the nutrient dosage

Published specifications for this part include Power Supply: 115 VAC, 230 VAC, 50/60Hz; Design: IP54; Measuring principle: UV photometric; Input: 8 signal inputs 24 V DC, ative, load max. 500 Ohm; Process pressure: Pressure free; Process temperature: 0 to 40 °C (32 to 104 °F); Sample flow rate: 20 ml/min (0.32 US gal/hr); Consumables: Stripp reagent, KHP or citric acid standard. The complete technical table is shown in the Specifications tab on this page.

Specifications

Ambient temperature 5 to 35 °C (41 to 95 °F)
Application Industrial wastewater monitoring Control of process wastewater Monitoring of industrial surface water Recording of the carbon load to control the nutrient dosage
Characteristic Analyzer for online-determination of TOC in aqueous media using thermic catalytic combustion
Consistency of the sample Aqueous Flammable substances are not allowed in ignitable concentrations, in such cases a sample dilution is required
Consumables Stripp reagent, KHP or citric acid standard
Design IP54
Input 8 signal inputs 24 V DC, ative, load max. 500 Ohm
Measuring principle UV photometric
Measuring range 0.25 to 600 mg TOC/l 1 to 2400 mg TOC/l 2.5 to 6000 mg TOC/l 5 to 12000 mg TOC/l With the optional pre-dilution the measuring range will expand by the factor of 20
Output / communication 0/4 to 20 mA, galvanically separated Two channel version has an addtional one RS 232 C, propietary, for data output and remote control (optional)
Power Supply 115 VAC, 230 VAC, 50/60Hz
Process pressure Pressure free
Process temperature 0 to 40 °C (32 to 104 °F)
Sample flow rate 20 ml/min (0.32 US gal/hr)
Size 1558 x 785 x 400 mm 61.3 x 30.9 x 15.8 inch
Specials Heatable Salt Trap Exchange furnace concept pH-controlled acid dosage with TIC stripping

Product details

Manufacturer Endress+Hauser
Manufacturer part number CA72TOC
Product category Vision, Measurement & Identification
Published specifications 16 attributes listed
Related part numbers 1 other part number in this family

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for CA72TOC?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the CA72TOC?

CA72TOC is made by Endress+Hauser and is listed in our Vision, Measurement & Identification category. KKM Solutions is an independent distributor, not an authorized Endress+Hauser dealer: we source the exact Endress+Hauser part number CA72TOC, and the quote confirms condition and lead time before you order.

Is the CA72TOC new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the CA72TOC, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of CA72TOC?

No published lifecycle status is on file for CA72TOC. Endress+Hauser lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of CA72TOC?

Key specifications include Ambient temperature: 5 to 35 °C (41 to 95 °F); Application: Industrial wastewater monitoring Control of process wastewater Monitoring of industrial surface water Recording of the carbon load to control the nutrient dosage; Characteristic: Analyzer for online-determination of TOC in aqueous media using thermic catalytic combustion; Consistency of the sample: Aqueous Flammable substances are not allowed in ignitable concentrations, in such cases a sample dilution is required. The full specification table on this page lists every published attribute for this part.

How quickly can CA72TOC ship?

Lead time for CA72TOC is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Variants & Related Part Numbers

Other Endress+Hauser part numbers in this family:

Frequently Searched Endress+Hauser Part Numbers

Related Products

Technical Guides

All Sensors & Measurement articles ›

Browse more Endress+Hauser Sensors & Encoders, or see everything from Endress+Hauser.