Dwyer Instruments High precision valve, 16-turn, flow rate 201-400 mL/min air (7-12 mL/min water).

VA82 — Dwyer High precision valve, 16-turn, flow rate 201-400 mL/min air (7-12 mL/min water).

Brand: Dwyer Instruments SKU: VA82 Mfr Part #: VA82

KKM Solutions is an independent parts distributor, not an authorized Dwyer Instruments dealer — how we source.

Ships worldwide — lead time quoted per part

Dwyer Instruments VA82 - Variable Area Flow Meters - Accuracy: ± 2 %; Mounting orientation: Vertical; Repeatability: ± 0.25%.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number VA82 from Dwyer Instruments, listed in Pneumatics. Specifications on file: Accuracy ± 2 %; Country of origin United States; Gas Flow, Max 400 ml/min; Gas Flow, Min 201 ml/min. KKM Solutions quotes this part with pricing and availability confirmed per order.

Dwyer Instruments VA82 is a Variable Area Flow Meters catalog item from Dwyer Instruments. The manufacturer's published data for this part number specifies Accuracy: ± 2 % and Mounting orientation: Vertical.

The specification set recorded for this part number covers Repeatability: ± 0.25%; Operating temperature - max: 250 °F; Valve Type: 16-Turn Valve; Country of origin: United States; GrossWeightValue: 0.1; Materials, Wetted: 316 Stainless Steel, Fluoroelastomer, PCTFE (Polychlorotrifluoroethylene); Media Compatibility: Clean process / cooling water, HVAC / room air; Process Connection Size: 1/8 in; Process Connection Type: NPT Female; Proof Pressure: Up to 200 psi; Accuracy Detail: ± 2% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute); Applications: Fluid Measurement and Control, Industrial and Manufacturing. The complete technical table is shown in the Specifications tab on this page.

Specifications

Accuracy ± 2 %
Accuracy Detail ± 2% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute)
Applications Fluid Measurement and Control, Industrial and Manufacturing
Country of origin United States
Gas Flow, Max 400 ml/min
Gas Flow, Min 201 ml/min
Liquid Flow, Max 12 ml/min
Liquid Flow, Min 7 ml/min
Material Construction Option Stainless Steel
Materials, Wetted 316 Stainless Steel, Fluoroelastomer, PCTFE (Polychlorotrifluoroethylene)
Measurement Pressure Type Gauge
Media Compatibility Clean process / cooling water, HVAC / room air
Mounting orientation Vertical
Operating temperature - max 250 °F
Process Connection Size 1/8 in
Process Connection Type NPT Female
Proof Pressure Up to 200 psi
Repeatability ± 0.25%
Repeatability Note ± 0.25% of scale reading
Scale Length N/A
Tube Capacity N/A
Turndown Ratio 10:1
Turndown Ratio Note 10:1, 20:1 with combinations of two floats installed in meter
Valve Type 16-Turn Valve

Product details

Manufacturer Dwyer Instruments
Manufacturer part number VA82
Product category Pneumatics
Published specifications 24 attributes listed

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for VA82?

This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the VA82?

VA82 is made by Dwyer Instruments and is listed in our Pneumatics category. KKM Solutions is an independent distributor, not an authorized Dwyer Instruments dealer: we source the exact Dwyer Instruments part number VA82, and the quote confirms condition and lead time before you order.

Is the VA82 new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the VA82, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of VA82?

No published lifecycle status is on file for VA82. Dwyer Instruments lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of VA82?

Key specifications include Accuracy: ± 2 %; Accuracy Detail: ± 2% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute); Applications: Fluid Measurement and Control, Industrial and Manufacturing; Country of origin: United States. The full specification table on this page lists every published attribute for this part.

What thread or connection does VA82 use?

Per the published specification for VA82: Process Connection Size: 1/8 in; Process Connection Type: NPT Female. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

What operating temperature is VA82 rated for?

Per the published specification for VA82: Operating temperature - max: 250 °F. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How quickly can VA82 ship?

Lead time for VA82 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Related Products

Technical Guides

All Pneumatics & Air Systems articles ›

Browse more Dwyer Instruments Pneumatics, or see everything from Dwyer Instruments.