Dwyer Instruments IEFB-FB-PG-T10-LCD INSERTION ELECTROMAGNETIC ENERGY SYSTEM WITH DISPLAY, 4" (100 MM) PIPE, 1% OF READING, BSPT PROCESS C

Dwyer Instruments IEFB-FB-PG-T10-LCD — Electromagnetic Flow Meters

Brand: Dwyer Instruments SKU: IEFB-FB-PG-T10-LCD Mfr Part #: IEFB-FB-PG-T10-LCD
Ships Same Day* Worldwide Shipping

Dwyer Instruments IEFB-FB-PG-T10-LCD - Electromagnetic Flow Meters - Relative Humidity: 10 to 90% Non-Condensing; Electrical connection: Cable Gland with Screw Terminal block; Control Output: Alarm.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Dwyer Instruments IEFB-FB-PG-T10-LCD is an Electromagnetic Flow Meters catalog item from Dwyer Instruments. The manufacturer's published data for this part number specifies Relative Humidity: 10 to 90% Non-Condensing and Electrical connection: Cable Gland with Screw Terminal block.

High accuracy 4˝ (100 mm) pipe; 1% of reading, High accuracy units: ± 0.5% of reading at calibrated velocity, ± 1% of reading from 2 to 20 ft/s (0.6 to 6 m/s) ± 0.02 ft/s (± 0.006 m/s) at < 2 ft/s (0.6 m/s); Standard accuracy units: ± 1% FS The specification set recorded for this part number covers Control Output: Alarm; Output signal: Current, Voltage, DC Pulse; Accuracy: ± 1 % FS; Impedance: 4 to 20 mA: 536 Ω; 5V: 500 Ω; 10V: 1.27k Ω; Supply voltage: 12 to 42 Vdc, 12 to 36 Vac; Storage temperature, min: -40 °F; Display type: LCD; Operating temperature - max: 158 °F; Operating temperature - min: -4 °F; Country of origin: United States; GrossWeightValue: 12.5; Materials, Wetted: Polymer, Silicone, Stainless Steel. See the Specifications tab on this page for the full technical table.

Accuracy ± 1 % FS
Accuracy Detail High accuracy 4˝ (100 mm) pipe; 1% of reading, High accuracy units: ± 0.5% of reading at calibrated velocity, ± 1% of reading from 2 to 20 ft/s (0.6 to 6 m/s) ± 0.02 ft/s (± 0.006 m/s) at < 2 ft/s (0.6 m/s); Standard accuracy units: ± 1% FS
Applications Boilers, Energy Management Systems, Oil, Refrigeration, Refrigeration Equipment
Conductivity > 20 µS/cm
Control Output Alarm
Country of origin United States
Data Interface N/A
Display Note 2 x 2" (50 x 50 mm) Graphic LCD with Backlight
Display size 71 mm (2.8 in)
Display type LCD
Electrical connection Cable Gland with Screw Terminal block
Enclosure Ratings IP66, NEMA Type 4X
External Probe Lead Length 3 m (10 ft)
GrossWeightValue 12.5
Impedance 4 to 20 mA: 536 Ω; 5V: 500 Ω; 10V: 1.27k Ω
Linear Flow Rate, Max 20 ft/s
Linear Flow Rate, Min 0 ft/s
Materials Aluminum
Materials, Wetted Polymer, Silicone, Stainless Steel
Media Compatibility Conductive liquids, Corrosive chemicals / acids / bases
Operating temperature - max 158 °F
Operating temperature - min -4 °F
Output Detail (1) Analog: 4-20 mA, 0-5 V, 0-10 V or 2-10 V (display selectable); (1) Pulse/Frequency: 0-15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable); (2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable); (1) Reverse flow output indication
Output signal Current, Voltage, DC Pulse
Pipe Size, Max 4 in
Pipe Size, Min 4 in
Pressure Drop Note < 0.1 psi at 12 ft/s in 4" (<0.01 bar at 3.7 m/s in 100 mm) and Larger Pipe
Pressure Drop, Max 0.1 psi
Pressure Limits Up to 400 psi
Process Connection Size 1 in
Process Connection Type BSPT Male
Process Temperature, Max 250 °F
Process Temperature, Min 15 °F
Relative Humidity 10 to 90% Non-Condensing
Resistance Note Matched 4 Wire Platinum RTD’s
Storage Temperature, Max 185 °F
Storage temperature, min -40 °F
Straight Run Requirements >10 Diameter Upstream, >5 Diameter Downstream
Supply Power Note 12 to 42 Vdc, 0.25 A @ 24 Vdc; 12 to 36 Vac
Supply Power Type AC/DC
Supply voltage 12 to 42 Vdc, 12 to 36 Vac
Temperature Compensation 140 to 220°F < 2% error over ± 30°F Change , 40 to 70°F < 2% error over ± 10°F Change
Temperature Probe Style General Purpose Probe
Temperature Sensor Type RTD

Request a quote for this part

Email [email protected] or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for IEFB-FB-PG-T10-LCD?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email [email protected], and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the IEFB-FB-PG-T10-LCD?

IEFB-FB-PG-T10-LCD is a Dwyer Instruments part. KKM Solutions sources Dwyer Instruments components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

Is IEFB-FB-PG-T10-LCD discontinued, and can I still get one?

KKM Solutions does not publish a manufacturer lifecycle status for IEFB-FB-PG-T10-LCD — check Dwyer Instruments's own product page for whether it is current, superseded, or end-of-life. It does not change what we can do: we source current-production, superseded and long-obsolete parts the same way, and where a part is genuinely unavailable we identify a form-fit-function equivalent. Send the part number through the quote form on this page, or use our obsolete part lookup at https://kkmsolutions.com/tools/obsolete-part-lookup/.

What are the key specifications of IEFB-FB-PG-T10-LCD?

Key specifications include Accuracy: ± 1 % FS; Accuracy Detail: High accuracy 4˝ (100 mm) pipe; 1% of reading, High accuracy units: ± 0.5% of reading at calibrated velocity, ± 1% of reading from 2 to 20 ft/s (0.6 to 6 m/s) ± 0.02 ft/s (± 0.006 m/s) at < 2 ft/s (0.6 m/s); Standard accuracy units: ± 1% FS; Applications: Boilers, Energy Management Systems, Oil, Refrigeration, Refrigeration Equipment; Conductivity: > 20 µS/cm. The full specification table on this page lists every published attribute for this part.

How quickly can IEFB-FB-PG-T10-LCD ship?

In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products