Skip to content
Worldwide shipping · same-day dispatch on in-stock items* (825) 454-5367 Order desk 24/7 [email protected]
KKM Industrial and Automation Solutions Industrial Automation & MRO Parts Line down? Call the order desk (825) 454-536724/7
Call the order desk Get a quote
Dwyer Instruments 25115 TEMP/CONTROL T/C, CURR, W/ALARM

Dwyer 25115 TEMP/CONTROL T/C, CURR, W/ALARM

Brand: Dwyer Instruments SKU: 25115 Mfr Part #: 25115
Ships Same Day* Worldwide Shipping

Dwyer Instruments 25115 - PID Controllers - Weight: 13 oz; Input type: Thermocouple; Accuracy: ± 0.25% span ± 1°.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

This listing covers the Dwyer Instruments 25115, a part number in the PID Controllers category. The manufacturer's published data for this part number specifies Weight: 13 oz and Input type: Thermocouple.

Type K: -328 to 2372°F; Type J: -148 to 2192°F; Type T: -328 to 752°F; Type E: 32 to 1112°F; Type L: -328 to 1562°F

Published specifications for this part include Accuracy: ± 0.25% span ± 1°; Mounting orientation: 1/4 DIN; Isolation: 500 Vac; Supply voltage: 100 to 240 Vac, 132 to 240 Vdc; Power consumption: max 5 VA; Display type: LED; Operating temperature - max: 131 °F; Operating temperature - min: 14 °F; Country of origin: United States; Enclosure Ratings: IP65, NEMA Type 4X; Supply Power Type: AC/DC; Display Note: Two-4 digit, 7 segment, 0.56" high LED. The complete technical table is shown in the Specifications tab on this page.

Specifications

Accuracy ± 0.25% span ± 1°
Control Action Selectable for Reverse (Usually Heating) or Direct (Usually Cooling)
Country of origin United States
Current Output Range 4 to 20 mA
Display Note Two-4 digit, 7 segment, 0.56" high LED
Display resolution 1° / 0.1°
Display type LED
Enclosure Ratings IP65, NEMA Type 4X
Impedance Input 3 MΩ
Input type Thermocouple
Isolation 500 Vac
Memory Backup Non-Volatile
Mounting orientation 1/4 DIN
Number of Digits 4
Operating temperature - max 131 °F
Operating temperature - min 14 °F
Output Note Proportional Isolated Current: 0-20 mA, selectable, into 600 Ohms maximum
Output Type (A) Current
Output Type (B) N/A
Power consumption max 5 VA
Supply Power Note 100-240 VAC nominal, ± 10%, 50-400 Hz, single phase; 132-240 VDC nominal, ± 10%
Supply Power Type AC/DC
Supply voltage 100 to 240 Vac, 132 to 240 Vdc
Temperature Sensor Type Thermocouple
Thermocouple Input Range Note Type K: -328 to 2372°F; Type J: -148 to 2192°F; Type T: -328 to 752°F; Type E: 32 to 1112°F; Type L: -328 to 1562°F
Weight 13 oz

Product details

Manufacturer Dwyer Instruments
Manufacturer part number 25115
KKM catalog reference DWYER-25115
Product category Signaling & Indication
Published specifications 26 attributes listed
Related part numbers 3 other part numbers in this family

Request a quote for this part

Email [email protected] or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How do I get pricing for 25115?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email [email protected], and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 25115?

25115 is a Dwyer Instruments part. KKM Solutions sources Dwyer Instruments components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

Is 25115 discontinued, and can I still get one?

KKM Solutions does not publish a manufacturer lifecycle status for 25115 — check Dwyer Instruments's own product page for whether it is current, superseded, or end-of-life. It does not change what we can do: we source current-production, superseded and long-obsolete parts the same way, and where a part is genuinely unavailable we identify a form-fit-function equivalent. Send the part number through the quote form on this page, or use our obsolete part lookup at https://kkmsolutions.com/tools/obsolete-part-lookup/.

What are the key specifications of 25115?

Key specifications include Accuracy: ± 0.25% span ± 1°; Control Action: Selectable for Reverse (Usually Heating) or Direct (Usually Cooling); Country of origin: United States; Current Output Range: 4 to 20 mA. The full specification table on this page lists every published attribute for this part.

How quickly can 25115 ship?

In-stock items are dispatched the same business day for orders placed by 11 AM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Variants & Related Part Numbers

Other Dwyer Instruments part numbers in this family:

  • 25111Dwyer Temperature controller, thermocouple input, SSR output, with alarm.
  • 25112Dwyer Temperature controller, thermocouple input, 5 VDC output, with alarm.
  • 25113Dwyer Temperature controller, thermocouple input, relay output, with alarm.

Related Products

Browse more Dwyer Instruments Signaling & Indication, or see everything from Dwyer Instruments.