Photo on request: ask us for an image of this part
080Z0018 Danfoss AK-XM 204B I/O Module, 8 digital outputs with override board
KKM Solutions is an independent parts distributor, not an authorized Danfoss dealer — how we source.
Danfoss AK-XM 204B extension module for AK system controllers, 8 digital outputs with override board. Please email orderdesk@kkmsolutions.com to check stock for this item -- send the part number and the quantity you need and the order desk will come back with current availability, lead time and pricing, usually the same business day.
Overview
Part number 080Z0018 from Danfoss, listed in I/O Modules & Remote I/O. Specifications on file: Application Area Additional inputs and outputs; Approvals C-TICK, CE, UR; CE Mark Yes; Communication type AK2 local bus. KKM Solutions quotes this part with pricing and availability confirmed per order.
Danfoss 080Z0018 is the AK-XM 204B extension module, an I/O card for Danfoss AK refrigeration system controllers providing 8 digital outputs with override board. This is the output module, and the override board is the reason to specify this code rather than a plain output card: it lets a relay be forced manually at the module, so a plant can be run and a fault isolated with the controller offline. Extension modules are how an AK controller is sized to a plant: the controller carries the application software and the modules carry the terminals, so the same controller covers a small pack or a full supermarket rack by adding cards. That also means the module must match both the controller generation and the bus it sits on, so tell us the AK controller you are extending when you enquire and the order desk will confirm compatibility before quoting. Code number 080Z0018 is the Danfoss ordering reference and is the number to quote. Please email orderdesk@kkmsolutions.com to check stock for this item -- send the part number and the quantity you need and the order desk will come back with current availability, lead time and pricing, usually the same business day.
Specifications
| Application Area | Additional inputs and outputs |
|---|---|
| Approvals | C-TICK, CE, UR |
| CE Mark | Yes |
| Communication type | AK2 local bus |
| Controller type | Extension module |
| Digital Outputs (DO) | 8 pc |
| Display on Front | No |
| EAN | 5702428089326 |
| Function | Digital outputs |
| Override Board | Yes |
| Power consumption | 3.7 |
| Product group | I/O and communication modules |
| Series | Danfoss AK-XM (ADAP-KOOL extension I/O) |
| Terminations | Euro blocks |
| Type | AK-XM 204B |
Product details
| Manufacturer | Danfoss |
|---|---|
| Manufacturer part number | 080Z0018 |
| Product category | I/O Modules & Remote I/O |
| Published specifications | 15 attributes listed |
| Related part numbers | 2 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for 080Z0018?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 080Z0018?
080Z0018 is made by Danfoss and is listed in our I/O Modules & Remote I/O category. KKM Solutions is an independent distributor, not an authorized Danfoss dealer: we source the exact Danfoss part number 080Z0018, and the quote confirms condition and lead time before you order.
Is the 080Z0018 new and genuine?
Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.
What warranty comes with the 080Z0018, and can I return it?
Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.
What is the lifecycle status of 080Z0018?
No published lifecycle status is on file for 080Z0018. Danfoss lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.
What are the key specifications of 080Z0018?
Key specifications include Application Area: Additional inputs and outputs; Approvals: C-TICK, CE, UR; CE Mark: Yes; Communication type: AK2 local bus. The full specification table on this page lists every published attribute for this part.
What is the EAN or UPC barcode for 080Z0018?
Per the published specification for 080Z0018: EAN: 5702428089326. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can 080Z0018 ship?
Lead time for 080Z0018 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.
Variants & Related Part Numbers
Other Danfoss part numbers in this family:
Frequently Searched Danfoss Part Numbers
Related Products
Photo on request
Danfoss 080Z0020 AK-XM 107A I/O Module, 8 digital inputs
Photo on request
Danfoss 080Z0023 AK-XM 208C I/O Module, 8 analog inputs…
Omron Omron B7A-R3A13-M | Omron B7A 32-Point NPN Transistor I/O…
Omron Omron B7A-T6D7 | Omron Transistor I/O Link Module
Omron Omron C120-LK201-V1 | Omron Host Link Communication Module for…
Omron Omron C20P-EDR-A | Omron C20 I/O Module 12 DC…
Technical Guides
Browse more Danfoss PLCs & Industrial Computing, or see everything from Danfoss.
Looking for a discontinued or hard-to-find Danfoss part? Read our Obsolete Danfoss VLT guide, or use the obsolete part lookup.