Skip to content
Stock is confirmed when you order, and we will advise you as soon as your order is confirmed. Need help with a part? Email orderdesk@kkmsolutions.com.
Ships worldwide — lead time quoted per part (825) 454-5367 Order desk 24/7 orderdesk@kkmsolutions.com
KKM Industrial and Automation Solutions Industrial Automation & MRO Parts Line down? Call the order desk (825) 454-536724/7
Call the order desk Get a quote
Circutor R13862

R13862 Circutor Computer SMART III 12 Power Factor Regulator 12-Step RS-485

Brand: Circutor SKU: R13862 Mfr Part #: R13862

KKM Solutions is an independent parts distributor, not an authorized Circutor dealer — how we source.

Ships worldwide — lead time quoted per part

Circutor R13862 — power quality device (Computer SMART III 12): active energy accuracy 0.5% ± 2 digits, active power measurement accuracy 0.5% ± 1 digit, consumption 13...20 VA.

Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Overview

Part number R13862 from Circutor, listed in Air Preparation (FRL). Specifications on file: Active energy accuracy 0.5% ± 2 digits; Active power measurement accuracy 0.5% ± 1 digit; Circutor code R13862; Consumption 13...20 VA. KKM Solutions quotes this part with pricing and availability confirmed per order.

The Circutor R13862 is a power quality device (Computer SMART III 12). Published specifications for this part number include built to IEC 61010, IEC 61000-6-2, IEC 61000-6-4, IEC 61557-12, active energy accuracy 0.5% ± 2 digits, active power measurement accuracy 0.5% ± 1 digit, consumption 13...20 VA, digital inputs 2, optoisolated, potential-free contact. Further catalogue data covers digital relay outputs, digital transistor outputs, display, enclosure, input current, installation category, leakage current measurement range, maximum altitude. KKM Solutions sources Circutor components to order. Request a quote from KKM Solutions for current pricing, lead time and availability.

Specifications

Active energy accuracy 0.5% ± 2 digits
Active power measurement accuracy 0.5% ± 1 digit
Circutor code R13862
Consumption 13...20 VA
Digital inputs 2, optoisolated, potential-free contact
Digital relay outputs 14 total (12 step outputs, 1 fan, 1 alarm relay)
Digital transistor outputs 2 x NPN, 50 mA, 24 V DC
Display Custom COG LCD with capacitive 5-key keyboard and 4 LEDs
Input current .../5 A or .../1 A secondary
Installation category CAT III 300 V
Leakage current measurement range 0.01...1.5 A
Maximum altitude 2000 m
Maximum relay current 1 A
Maximum relay switching capacity 2500 VA
Minimum current measurement 50 mA
Minimum measurement voltage 20 V Ph-N, 35 V Ph-Ph
Model Computer SMART III 12
Motor Enclosure Plastic V0 self-extinguishing
Nominal measurement voltage 230 V Ph-N, 400 V Ph-Ph
Number of Steps 12
Phase current accuracy 0.5% ± 1 digit
Phase current measuring range 1...120% of In
Power Supply 100...520 V AC, 50...60 Hz
Protection class IP 51 front panel, IP 31 unmounted
Reactive energy accuracy Class 1
Relative Humidity 5...95% non-condensing
Relay electrical life 30 x 10³ cycles
Relay mechanical life 5 x 10⁶ cycles
Serial Communication Modbus RTU, RS-485
Size 144 × 144 × 71 mm, panel mount
Source stock status In stock at source
Standards IEC 61010, IEC 61000-6-2, IEC 61000-6-4, IEC 61557-12
Storage Temperature -20...+70 °C
Switching unit Contactor
Voltage Measurement Range 20...300 V Ph-N, 35...520 V Ph-Ph
Working temperature -10...+55 °C

Product details

Manufacturer Circutor
Manufacturer part number R13862
Product category Air Preparation (FRL)
Published specifications 36 attributes listed
Related part numbers 2 other part numbers in this family

Request a quote for this part

Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.

Quotes back within 1 business day — usually the same day. Need it faster? Call (825) 454-5367, answered 24/7.

Frequently Asked Questions

How much does R13862 cost?

R13862 is listed at CA$520.12 (CAD) and can be ordered directly from this page with Add to Cart. That figure is a reference price and can change: your card is authorized at checkout and charged only once our order desk confirms the part, stock, and final price, and we email you first if anything has moved. Larger quantities or custom terms — email orderdesk@kkmsolutions.com for a volume quote.

Who manufactures the R13862?

R13862 is made by Circutor and is listed in our Air Preparation (FRL) category. KKM Solutions is an independent distributor, not an authorized Circutor dealer: we source the exact Circutor part number R13862, and the quote confirms condition and lead time before you order.

Is the R13862 new and genuine?

Parts we supply are new and genuine unless the quote expressly states otherwise. Where a part is new-old-stock, from excess inventory, refurbished or open-box, the quote says so before you approve it.

What warranty comes with the R13862, and can I return it?

Parts we supply are warranted against manufacturing defects for 1 year from the date of delivery; where the manufacturer's own warranty is longer, the manufacturer's warranty applies. The warranty covers repair, replacement, or credit of the defective part and does not cover normal wear items, misapplication, improper installation, or consequential damages. Contact us within 30 days of delivery before returning anything — all returns need a return authorization from the order desk.

What is the lifecycle status of R13862?

No published lifecycle status is on file for R13862. Circutor lists whether a catalog number is current, superseded or end-of-life on its own product page, and our order desk confirms the status with the manufacturer at quote time, before you commit. Send the part number through the quote form on this page.

What are the key specifications of R13862?

Key specifications include Active energy accuracy: 0.5% ± 2 digits; Active power measurement accuracy: 0.5% ± 1 digit; Circutor code: R13862; Consumption: 13...20 VA. The full specification table on this page lists every published attribute for this part.

What voltage does R13862 use?

Per the published specification for R13862: Minimum measurement voltage: 20 V Ph-N, 35 V Ph-Ph; Nominal measurement voltage: 230 V Ph-N, 400 V Ph-Ph. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.

How quickly can R13862 ship?

Lead time for R13862 is quoted per order and confirmed on your quote, which our order desk sends within 1 business day. For a line-down emergency, call the 24/7 order desk at (825) 454-5367.

Variants & Related Part Numbers

Other Circutor part numbers in this family:

Related Products