300-DOD9311 Allen-Bradley NEMA Size 3 Contactor
KKM Solutions is an independent parts distributor, not an authorized Allen-Bradley dealer — how we source.
Allen-Bradley 300-DOD9311 - Contactors - Function: Energy-saving contactor; Ambient temperature: Storage range: -55...80 °C (-67...176 °F); Lifecycle Status: Active.
Overview
Part number 300-DOD9311 from Allen-Bradley, listed in NEMA Contactors & Starters. Specifications on file: Altitude, max 2000 m of installation site; Coil Electronic; Coil operating limits, dropout 30...60% x voltage @ 50/60 Hz; Coil operating limits, pick-up 85...10% x voltage @ 50/60 Hz. KKM Solutions quotes this part with pricing and availability confirmed per order.
In our catalog, the 300-DOD9311 from Allen-Bradley is listed under the Contactors category. The manufacturer's published data for this part number specifies Function: Energy-saving contactor and Ambient temperature: Storage range: -55...80 °C (-67...176 °F).
Sizes 0...3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1...3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4...8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.)
The specification set recorded for this part number covers Lifecycle Status: Active; Rated control supply voltage at AC 50 Hz: 100 V; Rated control supply voltage at AC 60 Hz: 100 V; Type of electrical connection of main circuit: Screw connection; Voltage type for actuating: AC/DC; Number of auxiliary contacts as normally open contact: 1; Number of auxiliary contacts as normally closed contact: 1; Rated control supply voltage at DC: 100 V; Rated isolation voltage (Ui): 600V per UL, CSA; Protection class: Contactor main contact: IP00; Rated voltage (Ue): 24V @ 48V, 110V @ 220V, 440V DC; Humidity: Non-condensing: 5...95%. See the Specifications tab on this page for the full technical table.
Specifications
| Altitude, max | 2000 m of installation site |
|---|---|
| Ambient temperature | Storage range: -55...80 °C (-67...176 °F) |
| Available short circuit ampere | 65,000A @ 480V max, circuit breaker, RMS symmetrical |
| Climatic withstand | Category B according to IEC 60947-1, annex Q |
| Coil | Electronic |
| Coil operating limits, dropout | 30...60% x voltage @ 50/60 Hz |
| Coil operating limits, pick-up | 85...10% x voltage @ 50/60 Hz |
| Contacts | Sizes 0...3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1...3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4...8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.) |
| Continuous ampere rating | 3-poles: 90 A |
| DIN fuses (gG) current rating | Type 2 (per IEC 60947-4-1): 80A @ 690V, 60 kA available fault current |
| Electromagnetic compatibility | IEC 60947-1 - Environment A and B |
| Features | Compact size, Sizes 00...5: AC/DC electronic coil with optional PLC interface, Sizes 6...8: AC/DC with PLC interface, Integrated surge suppression, Panel or DIN Rail mountable, Finger safe, Complete range of accessories, Meets global standards, Consists o |
| FLA | 105A @ 600V, 3-phase per UL/CSA HVAC applications |
| Function | Energy-saving contactor |
| Fuse type | H, J, R |
| General purpose current (enclosed) | 80A @ 600V per UL/CSA |
| Heat dissipation | 17.5 W |
| Horsepower rating, max | 3-poles: 7.5Hp @ 115V, single-phase, full-load current must not exceed continuous Aere rating (60 Hz) |
| Humidity | Non-condensing: 5...95% |
| Lifecycle Status | Active |
| LRA | 630 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications |
| MCCB current rating | Type 2 (per IEC 60947-4-1): 880A @ 400V, 70 kA available fault current |
| Mechanical life | 10 mons of ops |
| NEMA size | 00...8 |
| Number of auxiliary contacts as normally closed contact | 1 |
| Number of auxiliary contacts as normally open contact | 1 |
| Number of auxiliary contacts, max | 8 |
| Operating limits, dropout | (≤0.60) x Us @ DC control |
| Operating limits, pick-up | (0.80...1.1) x Us @ DC control |
| Operating position | Vertical |
| Operating time, closing delay | 20 ms |
| Operating time, drop-out | 10 ms |
| Operating time, opening delay | 10 ms |
| Operating time, pick-up | 20 ms |
| Operating volt amperes | 200VA @ 50/60 Hz, inrush |
| Optional accessories | Side- or front-mount auxiliary contacts, Mechanical interlocks, Terminal lugs, Terminal shields, Connecting bars |
| Protection class | Contactor main contact: IP00 |
| Rated control supply voltage at AC 50 Hz | 100 V |
| Rated control supply voltage at AC 60 Hz | 100 V |
| Rated control supply voltage at DC | 100 V |
| Rated impulse voltage withstand (Uimp) | 8 kV |
| Rated isolation voltage (Ui) | 600V per UL, CSA |
| Rated operational current (Ie) | 85A @ 690V, AC-1 active power load (50/60 Hz), ambient temperature 70 °C (158 °F) |
| Rated operational current and power | 56A @ 115V AC, 500000 electrical ops, 1-phase per UL/CSA elevator duty |
| Rated operational current and power (enclosed) | 89A @ 250V DC, with 3-poles in series per UL/CSA |
| Rated operational power (Pe) | 90 kW @ 415V, AC-1 active power load (50/60 Hz), ambient temperature 40 °C (104 °F) |
| Rated voltage (Ue) | 24V @ 48V, 110V @ 220V, 440V DC |
| Required torque | Load: 40 lbin |
| Shock resistance | IEC 60068-2-27 |
| Standard coil, hold-in | 2.2VA/2 W @ 100...250V AC/DC |
| Standard coil, pick-up | 50VA/50 W @ 100...250V AC/DC |
| Switching of DC loads | 3-poles in series: 125A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C) |
| Switching of lighting loads | Tungsten lA: 105A @ 600V, 3-phase (break all lines) per UL/CSA |
| Switching of power transformers | Apparent power: 99 kVA @ 600V @ 60Hz (n = 20) |
| Type of electrical connection of main circuit | Screw connection |
| UL class J and CSA HRCI-J fuses rating | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 200A @ 600V, 100 kA available fault current |
| UL class RK5 fuses rating | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 200A @ 600V, 10 kA available fault current |
| UL inverse-time circuit breaker | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 250A @ 600V, 50 kA available fault current |
| Vibration resistance | IEC 60068-2-6 |
| Voltage type for actuating | AC/DC |
| Wire size | Load: 14...1 AWG for power terminals |
Product details
| Manufacturer | Allen-Bradley |
|---|---|
| Manufacturer part number | 300-DOD9311 |
| Product category | NEMA Contactors & Starters |
| Manufacturer lifecycle status | Active |
| Published specifications | 61 attributes listed |
| Related part numbers | 2 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for 300-DOD9311?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 300-DOD9311?
300-DOD9311 is an Allen-Bradley part, sourced to the exact manufacturer specification.
What is the lifecycle status of 300-DOD9311?
Manufacturer lifecycle status on file for 300-DOD9311: "Active" — not recorded as discontinued. That is the value published in the product data we hold; confirm against Allen-Bradley's own product page before a long-lead order, as feed data can lag an announcement. It does not change what we can do: KKM Solutions sources current-production, superseded and long-obsolete parts the same way. Send 300-DOD9311 through the quote form on this page for pricing and availability.
What are the key specifications of 300-DOD9311?
Key specifications include Altitude, max: 2000 m of installation site; Ambient temperature: Storage range: -55...80 °C (-67...176 °F); Available short circuit ampere: 65,000A @ 480V max, circuit breaker, RMS symmetrical; Climatic withstand: Category B according to IEC 60947-1, annex Q. The full specification table on this page lists every published attribute for this part.
How quickly can 300-DOD9311 ship?
Lead time is quoted per part and confirmed on your quote.
Variants & Related Part Numbers
Other Allen-Bradley part numbers in this family:
Related Products
Allen-Bradley Allen-Bradley NEMA Size 2 Contactor 300-COY9311
Allen-Bradley Allen-Bradley NEMA Size 3 Contactor 300-DOJ9400
Allen-Bradley Allen-Bradley NEMA Size 2 Contactor 300-COB9400
Allen-Bradley Allen-Bradley NEMA Size 3 Contactor 300-DOY9400
Allen-Bradley Allen-Bradley NEMA Size 1 Contactor 300-BOY9400
Allen-Bradley Allen-Bradley NEMA Size 4 Contactor Box Lug Connection 300-EOD9311-L
Browse more Allen-Bradley Contactors & Motor Starters, or see everything from Allen-Bradley.
Looking for a discontinued or hard-to-find Allen-Bradley part? Read our Allen-Bradley Lifecycle Status guide, or use the obsolete part lookup.