Worldwide shipping · same-day dispatch on in-stock items* Login / Register  ·  orderdesk@kkmsolutions.com
KKM Solutions Industrial & MRO Parts
Need a part fast?Request a free quote
300-DOD9311
Request a Quote Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Quoting several parts? Build one list, get one quote.
Sourced to exact specCross-checked against manufacturer part data
Fast quote turnaroundOur order desk replies within 1 business day
Worldwide shippingWe ship to your site, warehouse, or freight forwarder

Allen-Bradley NEMA Size 3 Contactor 300-DOD9311

Brand: Allen-Bradley SKU: 300-DOD9311
Ships Same Day* Worldwide Shipping

Allen-Bradley 300-DOD9311 - industrial components - Function: Energy-saving contactor; Ambient temperature: Storage range: -55...80 °C (-67...176 °F); Lifecycle Status: Active.

The 300-DOD9311 from Allen-Bradley is listed under industrial components in our catalog. The manufacturer's published data for this part number specifies Function: Energy-saving contactor and Ambient temperature: Storage range: -55...80 °C (-67...176 °F).

Sizes 0...3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1...3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4...8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.)

The specification set recorded for this part number covers Lifecycle Status: Active; Build America, Buy America: No; Repair Options Available: No; Rated control supply voltage at AC 50 Hz: 100 V; Rated control supply voltage at AC 60 Hz: 100 V; Type of electrical connection of main circuit: Screw connection; Voltage type for actuating: AC/DC; Number of auxiliary contacts as normally open contact: 1; Number of auxiliary contacts as normally closed contact: 1; Rated control supply voltage at DC: 100 V; Rated isolation voltage (Ui): 600V per UL, CSA; Protection class: Contactor main contact: IP00. See the Specifications tab on this page for the full technical table.

Altitude, max 2000 m of installation site
Ambient temperature Storage range: -55...80 °C (-67...176 °F)
Available short circuit ampere 65,000A @ 480V max, circuit breaker, RMS symmetrical
Build America, Buy America No
Climatic withstand Category B according to IEC 60947-1, annex Q
Coil Electronic
Coil operating limits, dropout 30...60% x voltage @ 50/60 Hz
Coil operating limits, pick-up 85...10% x voltage @ 50/60 Hz
Contacts Sizes 0...3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1...3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4...8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.)
Continuous ampere rating 3-poles: 90 A
DIN fuses (gG) current rating Type 2 (per IEC 60947-4-1): 80A @ 690V, 60 kA available fault current
Electromagnetic compatibility IEC 60947-1 - Environment A and B
Features Compact size, Sizes 00...5: AC/DC electronic coil with optional PLC interface, Sizes 6...8: AC/DC with PLC interface, Integrated surge suppression, Panel or DIN Rail mountable, Finger safe, Complete range of accessories, Meets global standards, Consists o
FLA 105A @ 600V, 3-phase per UL/CSA HVAC applications
Function Energy-saving contactor
Fuse type H, J, R
General purpose current (enclosed) 80A @ 600V per UL/CSA
Heat dissipation 17.5 W
Horsepower rating, max 3-poles: 7.5Hp @ 115V, single-phase, full-load current must not exceed continuous Aere rating (60 Hz)
Humidity Non-condensing: 5...95%
Lifecycle Status Active
LRA 630 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
MCCB current rating Type 2 (per IEC 60947-4-1): 880A @ 400V, 70 kA available fault current
Mechanical life 10 mons of ops
NEMA size 00...8
Number of auxiliary contacts as normally closed contact 1
Number of auxiliary contacts as normally open contact 1
Number of auxiliary contacts, max 8
Operating limits, dropout (≤0.60) x Us @ DC control
Operating limits, pick-up (0.80...1.1) x Us @ DC control
Operating position Vertical
Operating time, closing delay 20 ms
Operating time, drop-out 10 ms
Operating time, opening delay 10 ms
Operating time, pick-up 20 ms
Operating volt amperes 200VA @ 50/60 Hz, inrush
Optional accessories Side- or front-mount auxiliary contacts, Mechanical interlocks, Terminal lugs, Terminal shields, Connecting bars
Protection class Contactor main contact: IP00
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Rated control supply voltage at DC 100 V
Rated impulse voltage withstand (Uimp) 8 kV
Rated isolation voltage (Ui) 600V per UL, CSA
Rated operational current (Ie) 85A @ 690V, AC-1 active power load (50/60 Hz), ambient temperature 70 °C (158 °F)
Rated operational current and power 56A @ 115V AC, 500000 electrical ops, 1-phase per UL/CSA elevator duty
Rated operational current and power (enclosed) 89A @ 250V DC, with 3-poles in series per UL/CSA
Rated operational power (Pe) 90 kW @ 415V, AC-1 active power load (50/60 Hz), ambient temperature 40 °C (104 °F)
Rated voltage (Ue) 24V @ 48V, 110V @ 220V, 440V DC
Repair Options Available No
Required torque Load: 40 lbin
Shock resistance IEC 60068-2-27
Standard coil, hold-in 2.2VA/2 W @ 100...250V AC/DC
Standard coil, pick-up 50VA/50 W @ 100...250V AC/DC
Switching of DC loads 3-poles in series: 125A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C)
Switching of lighting loads Tungsten lA: 105A @ 600V, 3-phase (break all lines) per UL/CSA
Switching of power transformers Apparent power: 99 kVA @ 600V @ 60Hz (n = 20)
Type of electrical connection of main circuit Screw connection
UL class J and CSA HRCI-J fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 200A @ 600V, 100 kA available fault current
UL class RK5 fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 200A @ 600V, 10 kA available fault current
UL inverse-time circuit breaker Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 250A @ 600V, 50 kA available fault current
Vibration resistance IEC 60068-2-6
Voltage type for actuating AC/DC
Wire size Load: 14...1 AWG for power terminals

Frequently Asked Questions

How do I get pricing for 300-DOD9311?

KKM Solutions is a quote-based industrial supplier, so prices are not listed online. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.

Who manufactures the 300-DOD9311?

300-DOD9311 is a Allen-Bradley part. KKM Solutions sources Allen-Bradley components to the exact manufacturer specification and cross-checks every order against manufacturer part data before it ships.

What are the key specifications of 300-DOD9311?

Key specifications include Altitude, max: 2000 m of installation site; Ambient temperature: Storage range: -55...80 °C (-67...176 °F); Available short circuit ampere: 65,000A @ 480V max, circuit breaker, RMS symmetrical; Build America, Buy America: No. The full specification table on this page lists every published attribute for this part.

How quickly can 300-DOD9311 ship?

In-stock items are dispatched the same business day for orders placed by 3 PM; sourced and quoted items ship per the quoted lead time. KKM Solutions ships worldwide — to your site, warehouse, or freight forwarder.

Related Products