300-COD9400 Allen-Bradley NEMA Size 2 Contactor
KKM Solutions is an independent parts distributor, not an authorized Allen-Bradley dealer — how we source.
Allen-Bradley 300-COD9400 - Contactors - Function: Energy-saving contactor; Weight: AC/DC (electronic): 0.98 kg (2.16 lbs.); Ambient temperature: Storage range: -55...80 °C (-67...176 °F).
Overview
Part number 300-COD9400 from Allen-Bradley, listed in NEMA Contactors & Starters. Specifications on file: Altitude, max 2000 m of installation site; Coil Electronic; Coil operating limits, dropout 30...60% x voltage @ 50/60 Hz; Coil operating limits, pick-up 85...10% x voltage @ 50/60 Hz. KKM Solutions quotes this part with pricing and availability confirmed per order.
This listing covers the Allen-Bradley 300-COD9400, a part number in the Contactors category. The manufacturer's published data for this part number specifies Function: Energy-saving contactor and Weight: AC/DC (electronic): 0.98 kg (2.16 lbs.).
Sizes 0...3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1...3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4...8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.)
Published specifications for this part include Ambient temperature: Storage range: -55...80 °C (-67...176 °F); Lifecycle Status: Active; Rated control supply voltage at AC 50 Hz: 100 V; Rated control supply voltage at AC 60 Hz: 100 V; Type of electrical connection of main circuit: Screw connection; Voltage type for actuating: AC/DC; Switching frequency, max: 600 ops/hr, AC-1; Number of auxiliary contacts as normally open contact: 0; Number of auxiliary contacts as normally closed contact: 0; Rated control supply voltage at DC: 100 V; Rated isolation voltage (Ui): 690V per IEC; Protection class: Contactor main contact: IP2X. See the Specifications tab on this page for the full technical table.
Specifications
| Altitude, max | 2000 m of installation site |
|---|---|
| Ambient temperature | Storage range: -55...80 °C (-67...176 °F) |
| Available short circuit ampere | 65,000A @ 480V max, circuit breaker, RMS symmetrical |
| Climatic withstand | Category B according to IEC 60947-1, annex Q |
| Coil | Electronic |
| Coil operating limits, dropout | 30...60% x voltage @ 50/60 Hz |
| Coil operating limits, pick-up | 85...10% x voltage @ 50/60 Hz |
| Contacts | Sizes 0...3: 3 power poles with internal N.O. or N.C. auxiliary contact or 4 power poles., Sizes 1...3: 3 power poles with side mounted N.O. / N.C. auxiliary contact or 4 power poles, Sizes 4...8: 3 main poles with 2 auxiliary contacts (1 N.O. and 1 N.C.) |
| DIN fuses (gG) current rating | Type 2 (per IEC 60947-4-1): 40A @ 690V, 60 kA available fault current |
| Electromagnetic compatibility | IEC 60947-1 - Environment A and B |
| Features | Compact size, Sizes 00...5: AC/DC electronic coil with optional PLC interface, Sizes 6...8: AC/DC with PLC interface, Integrated surge suppression, Panel or DIN Rail mountable, Finger safe, Complete range of accessories, Meets global standards, Consists o |
| FLA | 60A @ 600V, 3-phase per UL/CSA HVAC applications |
| Function | Energy-saving contactor |
| Fuse type | H, J, R |
| General purpose current (enclosed) | 34A @ 600V per UL/CSA |
| Heat dissipation | 11.5 W |
| Humidity | Non-condensing: 5...95% |
| Lifecycle Status | Active |
| LRA | 360 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications |
| Main current circuit resistance | 0.21 mΩ |
| MCCB current rating | Type 2 (per IEC 60947-4-1): 520A @ 400V, 70 kA available fault current |
| Mechanical life | 12 mons of ops |
| NEMA size | 00...8 |
| Number of auxiliary contacts as normally closed contact | 0.000000 |
| Number of auxiliary contacts as normally open contact | 0.000000 |
| Number of auxiliary contacts, max | 8 |
| Number of normally closed contacts as main contact | 0.000000 |
| Number of normally open contacts as main contact | 4 |
| Operating limits, dropout | (≤0.60) x Us @ DC control |
| Operating limits, pick-up | (0.80...1.1) x Us @ DC control |
| Operating position | Vertical |
| Operating time, closing delay | 15 ms |
| Operating time, drop-out | 10 ms |
| Operating time, opening delay | 10 ms |
| Operating time, pick-up | 15 ms |
| Operating volt amperes | 130VA @ 50/60 Hz, inrush |
| Optional accessories | Side- or front-mount auxiliary contacts, Mechanical interlocks, Terminal lugs, Terminal shields, Connecting bars |
| Power dissipation | 7 W per pole at Ie, AC-1, 400V |
| Protection class | Contactor main contact: IP2X |
| Rated control supply voltage at AC 50 Hz | 100 V |
| Rated control supply voltage at AC 60 Hz | 100 V |
| Rated control supply voltage at DC | 100 V |
| Rated current | 4-Pole: 70A @ 690V, AC-1, Ie at 40 °C |
| Rated impulse voltage withstand (Uimp) | 6 kV |
| Rated isolation voltage (Ui) | 690V per IEC |
| Rated operational current (Ie) | 70A @ 690V, AC-1 active power load (50/60 Hz), ambient temperature 40 °C (104 °F) |
| Rated operational current and power | 5Hp @ 230V AC, 500000 electrical ops, 1-phase per UL/CSA elevator duty |
| Rated operational current and power (enclosed) | 7.5Hp @ 240V, 1-phase per UL/CSA |
| Rated operational power (Pe) | 84 kW @ 690V, AC-1 active power load (50/60 Hz), ambient temperature 40 °C (104 °F) |
| Rated voltage (Ue) | 24V @ 48V, 110V @ 220V, 440V DC |
| Required torque | Load: 25 lbin |
| Shock resistance | IEC 60068-2-27 |
| Short time withstand (Icw) | 3-pole: 600A @ 10s (40 °C) |
| Standard coil, hold-in | 2.2VA/2 W @ 100...250V AC/DC |
| Standard coil, pick-up | 50VA/50 W @ 100...250V AC/DC |
| Switching frequency, max | 600 ops/hr, AC-1 |
| Switching of DC loads | 3-poles in series: 70A @ 220V (Shunt-wound motors starting, reverse current breaking, reversing, stepping DC-3 at 60 °C) |
| Switching of lighting loads | Tungsten lA: 65A @ 600V, 3-phase (break all lines) per UL/CSA |
| Switching of power transformers | Apparent power: 87 kVA @ 600V @ 60Hz (n = 15) |
| Total power dissipation | 10.1 W at Ie, AC-3, 400V, AC/DC control (120-250V) |
| Type of electrical connection of main circuit | Screw connection |
| UL class J and CSA HRCI-J fuses rating | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 150A @ 600V, 100 kA available fault current |
| UL class RK5 fuses rating | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 150A @ 600V, 5 kA available fault current |
| UL inverse-time circuit breaker | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 250A @ 600V, 5 kA available fault current |
| Vibration resistance | IEC 60068-2-6 |
| Voltage type for actuating | AC/DC |
| Weight | AC/DC (electronic): 0.98 kg (2.16 lbs.) |
| Wire size | Load: 14...4 AWG for power terminals |
Product details
| Manufacturer | Allen-Bradley |
|---|---|
| Manufacturer part number | 300-COD9400 |
| Product category | NEMA Contactors & Starters |
| Manufacturer lifecycle status | Active |
| Published specifications | 68 attributes listed |
| Related part numbers | 2 other part numbers in this family |
Request a quote for this part
Email orderdesk@kkmsolutions.com or call (825) 454-5367 for pricing and availability.
Frequently Asked Questions
How do I get pricing for 300-COD9400?
This part is quoted on request, so no price is listed for it here. Send the quote form on this page with your quantity, or email orderdesk@kkmsolutions.com, and our order desk will reply with pricing and availability within 1 business day.
Who manufactures the 300-COD9400?
300-COD9400 is an Allen-Bradley part, sourced to the exact manufacturer specification.
What is the lifecycle status of 300-COD9400?
Manufacturer lifecycle status on file for 300-COD9400: "Active" — not recorded as discontinued. That is the value published in the product data we hold; confirm against Allen-Bradley's own product page before a long-lead order, as feed data can lag an announcement. It does not change what we can do: KKM Solutions sources current-production, superseded and long-obsolete parts the same way. Send 300-COD9400 through the quote form on this page for pricing and availability.
What are the key specifications of 300-COD9400?
Key specifications include Altitude, max: 2000 m of installation site; Ambient temperature: Storage range: -55...80 °C (-67...176 °F); Available short circuit ampere: 65,000A @ 480V max, circuit breaker, RMS symmetrical; Climatic withstand: Category B according to IEC 60947-1, annex Q. The full specification table on this page lists every published attribute for this part.
What voltage does 300-COD9400 use?
Per the published specification for 300-COD9400: Rated control supply voltage at AC 50 Hz: 100 V; Rated control supply voltage at AC 60 Hz: 100 V. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
What is the current rating of 300-COD9400?
Per the published specification for 300-COD9400: DIN fuses (gG) current rating: Type 2 (per IEC 60947-4-1): 40A @ 690V, 60 kA available fault current; MCCB current rating: Type 2 (per IEC 60947-4-1): 520A @ 400V, 70 kA available fault current. Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How much does 300-COD9400 weigh?
Per the published specification for 300-COD9400: Weight: AC/DC (electronic): 0.98 kg (2.16 lbs.). Confirm against the full specification table on this page, or ask our order desk to verify it with the manufacturer at quote time.
How quickly can 300-COD9400 ship?
Lead time is quoted per part and confirmed on your quote.
Variants & Related Part Numbers
Other Allen-Bradley part numbers in this family:
Related Products
Allen-Bradley Allen-Bradley NEMA Size 2 Contactor 300-COB9311
Allen-Bradley Allen-Bradley NEMA Size 2 Contactor 300-COJ9311
Allen-Bradley Allen-Bradley NEMA Size 1 Contactor 300-BOQJ9400
Allen-Bradley Allen-Bradley NEMA Size 2 Contactor 300-COJ9400
Allen-Bradley Allen-Bradley NEMA Size 1 Contactor 300-BOEQ9400
Allen-Bradley Allen-Bradley NEMA Size 2 Contactor 300-COY9400
Browse more Allen-Bradley Contactors & Motor Starters, or see everything from Allen-Bradley.
Looking for a discontinued or hard-to-find Allen-Bradley part? Read our Allen-Bradley Lifecycle Status guide, or use the obsolete part lookup.
Industrial Automation & MRO Parts