Danfoss Code Numbers Explained: 060G, 067B, 032U
Danfoss labels its products with a code number such as 067B3342 or 032U7125. Unlike many part numbers, it is not built from readable fields like voltage or size: it is an ordering code for one exact product. The first characters do point to a product group, though, and knowing which group saves time when you only have a worn label. Every code below was read on Danfoss's own product listings.
How is a Danfoss code number built?
Most codes are three digits, a letter and four digits: 067B3342, 023Z0050, 060G1102. A few run longer, such as 061B811666 or 031E021566. The first four characters (067B, 023Z, 060G) group related products, and the last digits pick one item in that group. There is no rule you can use to work out the size or rating from the digits, so the code has to be looked up.
Which products sit behind the common prefixes?
These are the groups we found when we looked up codes people search for. Treat the table as a guide, not a rule: one prefix can hold more than one product family.
| Prefix | Example | Danfoss listing |
|---|---|---|
| 060G | 060G1102, 060G1711 | Pressure transmitters (MBS 3000, MBS 3350, AKS 33) |
| 067B | 067B3342, 067B4032 | TE expansion valve elements and valve bodies |
| 067G | 067G2701, 067G3302 | TE 55 orifices and elements |
| 067N | 067N2159 | TGE thermostatic expansion valves |
| 023Z | 023Z0050, 023Z5058 | DML hermetic filter driers |
| 032U | 032U7125 | EV220B solenoid valves |
| 032F | 032F1204 | EVR solenoid valves |
| 018F, 018Z | 018F6701, 018Z6596 | Solenoid valve coils |
| 060L, 061B | 060L310466, 061B810566 | KPS and MBC 8100 thermostats |
| 130B | 130B1078, 130B1135 | VLT spare parts and options (LCP 102 panel, MCA 120 PROFINET) |
| 131B | 131B0048 | VLT AutomationDrive FC 302 |
| 132F | 132F0020 | VLT Micro Drive FC 51 |
One character matters: 060G is a pressure transmitter group, but 060L310466 is a KPS79 thermostat. Copy the code exactly.
Why is 067B3342 not a complete expansion valve?
This is the most common surprise. Danfoss sells the TE 5 to TE 55 expansion valves as a parts program: the thermostatic element, the orifice and the valve body each have their own code. 067B3342 is listed as an element for a TE 5 valve, for R404A/R507A, externally equalized, -40 to 10 °C, with a 3,000 mm capillary tube. It does not include the body or the orifice.
- 067B3250: TE 5 element for R22/R407C. Same valve size, different refrigerant.
- 067B3210 (TE 12) and 067B3352 (TE 20): elements for larger valves.
- 067G2701: an orifice, size 10, for the TE 55.
- 067B4032: a valve body used with the TE 5, 5/8 in. solder inlet x 7/8 in. solder outlet.
By contrast, 067N2159 is listed as a complete TGE thermostatic expansion valve. When you replace a failed TE valve, check whether the element, the orifice or the body failed, and order each part by its own code. The refrigerant on the element must match the system.
What do the filter drier codes tell you?
The DML codes differ by core size and connection, and both matter:
| Code | Core | Connection |
|---|---|---|
| 023Z5040 | 08 cu.in. | 3/8 in. flare |
| 023Z5058 | 08 cu.in. | 3/8 in. solder (ODF), copper |
| 023Z5064 | 16 cu.in. | 3/8 in. solder (ODF), copper |
| 023Z0050 | 30 cu.in. | 1/2 in. flare |
| 023Z0071 | 30 cu.in. | 7/8 in. solder (ODF), copper |
A flare drier will not fit a brazed line, so check the connection type before you order.
How do you read the solenoid valve and coil codes?
For EV220B valves, the code picks the port size and flow. Danfoss lists 032U1251 as normally closed, G 1/2, Kv 1.5 m³/h; 032U7125 as G 1, Kv 11; 032U7132 as G 1 1/4, Kv 18; and 032U7150 as G 2, Kv 40, all with EPDM seals. G is the ISO 228-1 parallel thread. The coil is a separate code: 018F6701 is a BE230AS coil for 220-230 V AC with a terminal box, and 018Z6596 a BO024D coil for 24 V DC with a 5 m cable. A valve and a coil from the same family still need the right voltage. For the basics, see what a solenoid valve is and how to choose one.
Why do two codes sometimes describe the same product?
Danfoss lists some items twice with a different packing format, and names the other code under "Identical product". 032U8125 is listed as identical to 032U7125 and comes in an industrial pack of 8. 018F8701 is identical to 018F6701 (industrial pack of 50), and 060G4061 to 060G1102 (industrial pack of 14). The part is the same; the box differs. The reverse also happens: 060G2110 and 060G2115 are both AKS 33 transmitters for 0-25 bar, so compare the full listing before you treat them as the same. For transmitter basics, see pressure switches vs transmitters.
What about VLT drives?
Drives carry both a code number and a longer type code. 132F0020 has the type code FC-051P1K5T4E20H3BXCXXXSXXX, and its listing reads 1.5 kW, three phase, 380-480 V AC, IP20. Compare 132F0016 (FC-051P3K7T2E20H3...), listed as 3.7 kW at 200-240 V three phase, and 132F0001 (FC-051PK18S2E20H3...), 0.18 kW single phase. Send both numbers when you replace a drive. Older VLT units are covered in our obsolete Danfoss VLT parts guide.
Questions people ask about Danfoss codes
What is 067B3342?
A TE 5 expansion valve element for R404A/R507A, externally equalized. The orifice and valve body are separate parts.
What is 060G1475?
Danfoss lists it as an MBS 3350 pressure transmitter, 0-10 bar (0-145 psi).
Can I work out a code from the type name?
Not reliably. Look up the type, then pick the listing that matches the size, connection and voltage.
Is 032U8125 the same valve as 032U7125?
Danfoss lists them as identical products; 032U8125 is the industrial pack.
Further reading on this site: what a solenoid valve is and how to choose one; pressure switches vs transmitters; obsolete Danfoss VLT drive parts; Danfoss parts; request a quote.
Refrigerant and electrical work is for a qualified person. Need a Danfoss part? Request a quote with the full code number from the label, and the type code for drives, and we will source against that exact reference.
Need a quote on a specific part?
Request a Quote
Industrial Automation & MRO Parts